Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study

Detalhes bibliográficos
Autor(a) principal: Diniz Filho,Alberto
Data de Publicação: 2010
Outros Autores: Cronemberger,Sebastião, Ferreira,Dollores Martins, Mérula,Rafael Vidal, Calixto,Nassim
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000200011
Resumo: PURPOSE: To investigate, through ultrasound biomicroscopy images, the presence of plateau iris configuration in eyes with narrow-angle from patients with open-angle glaucoma and in eyes with previous acute primary angle-closure and compare the biometric features of eyes with plateau iris configuration with those of normal eyes. METHODS: Ultrasound biomicroscopic images from 196 patients with open-angle glaucoma and narrow-angle and 32 patients with acute primary angle-closure were retrospectively analyzed. The inclusion and specific criteria for the diagnosis of plateau iris configuration was the presence of an anterior positioning of the ciliary processes, supporting the peripheral iris so that it was parallel to the trabecular meshwork; the iris root had a steep rise from its insertion point, followed by a downward angulation from the corneoscleral wall; presence of a central flat iris plane; an absent (complete plateau iris configuration) or partially absent (incomplete plateau iris configuration) ciliary sulcus. The ultrasound biomicroscopic parameters were compared between complete and incomplete plateau iris configuration. The same parameters of both groups were compared with those of normal eyes. The following measurements were performed: anterior chamber depth; angle opening distance at 500 µm from the scleral spur; peripheral iris thickness at 500 µm from the scleral spur; iris-ciliary process distance; trabecular-ciliary process distance and angle recess area. RESULTS: Plateau iris configuration was found in 33 eyes of 20 (10.2%) out of 196 patients with open-angle glaucoma and narrow-angle and in 4 eyes of 2 (6.3%) out of 32 patients with acute primary angleclosure. Seventeen (77.3%) patients with plateau iris configuration were female and 5 (22.7%) male. Twenty-three (62.2%) out of 37 eyes had complete plateau iris configuration, and 14 (37.8%) had incomplete plateau iris configuration. Complete and incomplete plateau iris configuration presented similar biometric features with the exception of the iris-ciliary process distance. All plateau iris configuration eyes showed biometric parameters completely different from those of normal eyes except for peripheral iris thickness at 500 µm from the scleral spur. CONCLUSIONS: Plateau iris configuration was present in 10.2% of patients with open-angle glaucoma and narrow-angle and in 6.3% of patients with acute primary angle-closure. Biometric features were similar in eyes with complete and incomplete plateau iris configuration with the exception of iris-ciliary process distance. Compared to normal eyes, all plateau iris configuration eyes showed biometric parameters completely different except for peripheral iris thickness at 500 µm from the scleral spur.
id CBO-2_0f9299854d7506398d479c810e36a5ef
oai_identifier_str oai:scielo:S0004-27492010000200011
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic studyGlaucoma, angle-closureAnterior chamber/ultrasonographyGonioscopyIris diseasesPURPOSE: To investigate, through ultrasound biomicroscopy images, the presence of plateau iris configuration in eyes with narrow-angle from patients with open-angle glaucoma and in eyes with previous acute primary angle-closure and compare the biometric features of eyes with plateau iris configuration with those of normal eyes. METHODS: Ultrasound biomicroscopic images from 196 patients with open-angle glaucoma and narrow-angle and 32 patients with acute primary angle-closure were retrospectively analyzed. The inclusion and specific criteria for the diagnosis of plateau iris configuration was the presence of an anterior positioning of the ciliary processes, supporting the peripheral iris so that it was parallel to the trabecular meshwork; the iris root had a steep rise from its insertion point, followed by a downward angulation from the corneoscleral wall; presence of a central flat iris plane; an absent (complete plateau iris configuration) or partially absent (incomplete plateau iris configuration) ciliary sulcus. The ultrasound biomicroscopic parameters were compared between complete and incomplete plateau iris configuration. The same parameters of both groups were compared with those of normal eyes. The following measurements were performed: anterior chamber depth; angle opening distance at 500 µm from the scleral spur; peripheral iris thickness at 500 µm from the scleral spur; iris-ciliary process distance; trabecular-ciliary process distance and angle recess area. RESULTS: Plateau iris configuration was found in 33 eyes of 20 (10.2%) out of 196 patients with open-angle glaucoma and narrow-angle and in 4 eyes of 2 (6.3%) out of 32 patients with acute primary angleclosure. Seventeen (77.3%) patients with plateau iris configuration were female and 5 (22.7%) male. Twenty-three (62.2%) out of 37 eyes had complete plateau iris configuration, and 14 (37.8%) had incomplete plateau iris configuration. Complete and incomplete plateau iris configuration presented similar biometric features with the exception of the iris-ciliary process distance. All plateau iris configuration eyes showed biometric parameters completely different from those of normal eyes except for peripheral iris thickness at 500 µm from the scleral spur. CONCLUSIONS: Plateau iris configuration was present in 10.2% of patients with open-angle glaucoma and narrow-angle and in 6.3% of patients with acute primary angle-closure. Biometric features were similar in eyes with complete and incomplete plateau iris configuration with the exception of iris-ciliary process distance. Compared to normal eyes, all plateau iris configuration eyes showed biometric parameters completely different except for peripheral iris thickness at 500 µm from the scleral spur.Conselho Brasileiro de Oftalmologia2010-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000200011Arquivos Brasileiros de Oftalmologia v.73 n.2 2010reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492010000200011info:eu-repo/semantics/openAccessDiniz Filho,AlbertoCronemberger,SebastiãoFerreira,Dollores MartinsMérula,Rafael VidalCalixto,Nassimeng2010-08-12T00:00:00Zoai:scielo:S0004-27492010000200011Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2010-08-12T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
title Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
spellingShingle Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
Diniz Filho,Alberto
Glaucoma, angle-closure
Anterior chamber/ultrasonography
Gonioscopy
Iris diseases
title_short Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
title_full Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
title_fullStr Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
title_full_unstemmed Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
title_sort Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study
author Diniz Filho,Alberto
author_facet Diniz Filho,Alberto
Cronemberger,Sebastião
Ferreira,Dollores Martins
Mérula,Rafael Vidal
Calixto,Nassim
author_role author
author2 Cronemberger,Sebastião
Ferreira,Dollores Martins
Mérula,Rafael Vidal
Calixto,Nassim
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Diniz Filho,Alberto
Cronemberger,Sebastião
Ferreira,Dollores Martins
Mérula,Rafael Vidal
Calixto,Nassim
dc.subject.por.fl_str_mv Glaucoma, angle-closure
Anterior chamber/ultrasonography
Gonioscopy
Iris diseases
topic Glaucoma, angle-closure
Anterior chamber/ultrasonography
Gonioscopy
Iris diseases
description PURPOSE: To investigate, through ultrasound biomicroscopy images, the presence of plateau iris configuration in eyes with narrow-angle from patients with open-angle glaucoma and in eyes with previous acute primary angle-closure and compare the biometric features of eyes with plateau iris configuration with those of normal eyes. METHODS: Ultrasound biomicroscopic images from 196 patients with open-angle glaucoma and narrow-angle and 32 patients with acute primary angle-closure were retrospectively analyzed. The inclusion and specific criteria for the diagnosis of plateau iris configuration was the presence of an anterior positioning of the ciliary processes, supporting the peripheral iris so that it was parallel to the trabecular meshwork; the iris root had a steep rise from its insertion point, followed by a downward angulation from the corneoscleral wall; presence of a central flat iris plane; an absent (complete plateau iris configuration) or partially absent (incomplete plateau iris configuration) ciliary sulcus. The ultrasound biomicroscopic parameters were compared between complete and incomplete plateau iris configuration. The same parameters of both groups were compared with those of normal eyes. The following measurements were performed: anterior chamber depth; angle opening distance at 500 µm from the scleral spur; peripheral iris thickness at 500 µm from the scleral spur; iris-ciliary process distance; trabecular-ciliary process distance and angle recess area. RESULTS: Plateau iris configuration was found in 33 eyes of 20 (10.2%) out of 196 patients with open-angle glaucoma and narrow-angle and in 4 eyes of 2 (6.3%) out of 32 patients with acute primary angleclosure. Seventeen (77.3%) patients with plateau iris configuration were female and 5 (22.7%) male. Twenty-three (62.2%) out of 37 eyes had complete plateau iris configuration, and 14 (37.8%) had incomplete plateau iris configuration. Complete and incomplete plateau iris configuration presented similar biometric features with the exception of the iris-ciliary process distance. All plateau iris configuration eyes showed biometric parameters completely different from those of normal eyes except for peripheral iris thickness at 500 µm from the scleral spur. CONCLUSIONS: Plateau iris configuration was present in 10.2% of patients with open-angle glaucoma and narrow-angle and in 6.3% of patients with acute primary angle-closure. Biometric features were similar in eyes with complete and incomplete plateau iris configuration with the exception of iris-ciliary process distance. Compared to normal eyes, all plateau iris configuration eyes showed biometric parameters completely different except for peripheral iris thickness at 500 µm from the scleral spur.
publishDate 2010
dc.date.none.fl_str_mv 2010-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000200011
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000200011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27492010000200011
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.73 n.2 2010
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209026368864256