Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study

Detalhes bibliográficos
Autor(a) principal: Stipp,Willian Nandi
Data de Publicação: 2013
Outros Autores: Ribeiro,Fabiano Rebouças, Tenor Junior,Antonio Carlos, Filardi Filho,Cantídio Salvador, Molin,Danilo Canesin Dal, Petros,Rodrigo Souto Borges, Brasil,Romulo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Ortopedia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000100052
Resumo: INTRODUCTION: The purpose of this study was to indentify the ulnar insertion of the LUCL using the olecranon tip and the radial head as parameters to guide the ligament reconstruction surgery. METHODS: Thirteen elbows of eight fresh cadavers were dissected for the study of the LUCL. The distances between the proximal and distal insertion of the LUCL (footprint), between the radial head and the footprint and between the olecranon tip and the footprint were measure with a digital pachimeter. RESULTS: The average distance from the radial head to the proximal and distal ulnar insertion of the LUCL was 13.6 and 22.99 mm, respectively. The average distance between the olecranon tip and the proximal and distal ulnar insertion of the LUCL was 38.25 and 47.6 respectively. The mean length of the LUCL footprint was 9.35 mm. CONCLUSIONS: The LUCL insertion has a wide footprint with average 9.3 mm (7.5-11 mm). Ulnar insertion half point be located at 18.2 mm of the radial head and at 42.9 mm of olecranon tip.
id SBOT-2_99cd88197b708eebf0cf29bc72f7ed4c
oai_identifier_str oai:scielo:S0102-36162013000100052
network_acronym_str SBOT-2
network_name_str Revista Brasileira de Ortopedia (Online)
repository_id_str
spelling Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver studyElbow/anatomy&histologyElbow/surgeryElbow JointCadaver INTRODUCTION: The purpose of this study was to indentify the ulnar insertion of the LUCL using the olecranon tip and the radial head as parameters to guide the ligament reconstruction surgery. METHODS: Thirteen elbows of eight fresh cadavers were dissected for the study of the LUCL. The distances between the proximal and distal insertion of the LUCL (footprint), between the radial head and the footprint and between the olecranon tip and the footprint were measure with a digital pachimeter. RESULTS: The average distance from the radial head to the proximal and distal ulnar insertion of the LUCL was 13.6 and 22.99 mm, respectively. The average distance between the olecranon tip and the proximal and distal ulnar insertion of the LUCL was 38.25 and 47.6 respectively. The mean length of the LUCL footprint was 9.35 mm. CONCLUSIONS: The LUCL insertion has a wide footprint with average 9.3 mm (7.5-11 mm). Ulnar insertion half point be located at 18.2 mm of the radial head and at 42.9 mm of olecranon tip. Sociedade Brasileira de Ortopedia e Traumatologia2013-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000100052Revista Brasileira de Ortopedia v.48 n.1 2013reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1016/j.rboe.2012.05.001info:eu-repo/semantics/openAccessStipp,Willian NandiRibeiro,Fabiano RebouçasTenor Junior,Antonio CarlosFilardi Filho,Cantídio SalvadorMolin,Danilo Canesin DalPetros,Rodrigo Souto BorgesBrasil,Romuloeng2013-06-06T00:00:00Zoai:scielo:S0102-36162013000100052Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2013-06-06T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
title Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
spellingShingle Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
Stipp,Willian Nandi
Elbow/anatomy&histology
Elbow/surgery
Elbow Joint
Cadaver
title_short Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
title_full Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
title_fullStr Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
title_full_unstemmed Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
title_sort Anatomical parameters in the lateral ulnar collateral ligament reconstruction: a cadaver study
author Stipp,Willian Nandi
author_facet Stipp,Willian Nandi
Ribeiro,Fabiano Rebouças
Tenor Junior,Antonio Carlos
Filardi Filho,Cantídio Salvador
Molin,Danilo Canesin Dal
Petros,Rodrigo Souto Borges
Brasil,Romulo
author_role author
author2 Ribeiro,Fabiano Rebouças
Tenor Junior,Antonio Carlos
Filardi Filho,Cantídio Salvador
Molin,Danilo Canesin Dal
Petros,Rodrigo Souto Borges
Brasil,Romulo
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Stipp,Willian Nandi
Ribeiro,Fabiano Rebouças
Tenor Junior,Antonio Carlos
Filardi Filho,Cantídio Salvador
Molin,Danilo Canesin Dal
Petros,Rodrigo Souto Borges
Brasil,Romulo
dc.subject.por.fl_str_mv Elbow/anatomy&histology
Elbow/surgery
Elbow Joint
Cadaver
topic Elbow/anatomy&histology
Elbow/surgery
Elbow Joint
Cadaver
description INTRODUCTION: The purpose of this study was to indentify the ulnar insertion of the LUCL using the olecranon tip and the radial head as parameters to guide the ligament reconstruction surgery. METHODS: Thirteen elbows of eight fresh cadavers were dissected for the study of the LUCL. The distances between the proximal and distal insertion of the LUCL (footprint), between the radial head and the footprint and between the olecranon tip and the footprint were measure with a digital pachimeter. RESULTS: The average distance from the radial head to the proximal and distal ulnar insertion of the LUCL was 13.6 and 22.99 mm, respectively. The average distance between the olecranon tip and the proximal and distal ulnar insertion of the LUCL was 38.25 and 47.6 respectively. The mean length of the LUCL footprint was 9.35 mm. CONCLUSIONS: The LUCL insertion has a wide footprint with average 9.3 mm (7.5-11 mm). Ulnar insertion half point be located at 18.2 mm of the radial head and at 42.9 mm of olecranon tip.
publishDate 2013
dc.date.none.fl_str_mv 2013-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000100052
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000100052
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.rboe.2012.05.001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
dc.source.none.fl_str_mv Revista Brasileira de Ortopedia v.48 n.1 2013
reponame:Revista Brasileira de Ortopedia (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Revista Brasileira de Ortopedia (Online)
collection Revista Brasileira de Ortopedia (Online)
repository.name.fl_str_mv Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv ||rbo@sbot.org.br
_version_ 1752122358652469248