Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode

Detalhes bibliográficos
Autor(a) principal: Cardoso,Rafael M.
Data de Publicação: 2017
Outros Autores: Dornellas,Rafael M., Lima,Ana P., Montes,Rodrigo H. O., Richter,Eduardo M., Munoz,Rodrigo A. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017000901650
Resumo: This work demonstrates the application of batch-injection analysis (BIA) with amperometric detection on a multi-walled carbon nanotube (MWCNT) modified electrode for the sensitive determination of the antioxidant pyrogallol in biodiesel. Samples were diluted in electrolyte (0.1 mol L-1 HClO4) before injection using an electronic micropipette on the BIA cell. The size effect of MWCNTs on electrochemical oxidation of pyrogallol was investigated and 3.5-fold increase in the amperometric sensitivity using the modified electrode with MWCNTs of shorter dimensions was obtained. This result was in agreement with cyclic voltammetry and electrochemical impedance spectroscopy measurements. After optimization of BIA parameters for the amperometric detection on the MWCNT-modified electrode, the proposed method presented a linear range from 0.3 to 1000 µmol L-1, detection limit of 0.013 µmol L-1, precision of 3%, and sample throughput of 240 h-1. Spiked biodiesel samples were analyzed and recovery values between 95-99% were obtained.
id SBQ-2_f7a3aeaa84588191fd4f3be6a50fe8a4
oai_identifier_str oai:scielo:S0103-50532017000901650
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrodeamperometrybiofuelcarbon nanotubeselectrocatalysisphenolic compoundsThis work demonstrates the application of batch-injection analysis (BIA) with amperometric detection on a multi-walled carbon nanotube (MWCNT) modified electrode for the sensitive determination of the antioxidant pyrogallol in biodiesel. Samples were diluted in electrolyte (0.1 mol L-1 HClO4) before injection using an electronic micropipette on the BIA cell. The size effect of MWCNTs on electrochemical oxidation of pyrogallol was investigated and 3.5-fold increase in the amperometric sensitivity using the modified electrode with MWCNTs of shorter dimensions was obtained. This result was in agreement with cyclic voltammetry and electrochemical impedance spectroscopy measurements. After optimization of BIA parameters for the amperometric detection on the MWCNT-modified electrode, the proposed method presented a linear range from 0.3 to 1000 µmol L-1, detection limit of 0.013 µmol L-1, precision of 3%, and sample throughput of 240 h-1. Spiked biodiesel samples were analyzed and recovery values between 95-99% were obtained.Sociedade Brasileira de Química2017-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017000901650Journal of the Brazilian Chemical Society v.28 n.9 2017reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20160316info:eu-repo/semantics/openAccessCardoso,Rafael M.Dornellas,Rafael M.Lima,Ana P.Montes,Rodrigo H. O.Richter,Eduardo M.Munoz,Rodrigo A. A.eng2017-07-28T00:00:00Zoai:scielo:S0103-50532017000901650Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2017-07-28T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
title Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
spellingShingle Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
Cardoso,Rafael M.
amperometry
biofuel
carbon nanotubes
electrocatalysis
phenolic compounds
title_short Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
title_full Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
title_fullStr Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
title_full_unstemmed Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
title_sort Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode
author Cardoso,Rafael M.
author_facet Cardoso,Rafael M.
Dornellas,Rafael M.
Lima,Ana P.
Montes,Rodrigo H. O.
Richter,Eduardo M.
Munoz,Rodrigo A. A.
author_role author
author2 Dornellas,Rafael M.
Lima,Ana P.
Montes,Rodrigo H. O.
Richter,Eduardo M.
Munoz,Rodrigo A. A.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Cardoso,Rafael M.
Dornellas,Rafael M.
Lima,Ana P.
Montes,Rodrigo H. O.
Richter,Eduardo M.
Munoz,Rodrigo A. A.
dc.subject.por.fl_str_mv amperometry
biofuel
carbon nanotubes
electrocatalysis
phenolic compounds
topic amperometry
biofuel
carbon nanotubes
electrocatalysis
phenolic compounds
description This work demonstrates the application of batch-injection analysis (BIA) with amperometric detection on a multi-walled carbon nanotube (MWCNT) modified electrode for the sensitive determination of the antioxidant pyrogallol in biodiesel. Samples were diluted in electrolyte (0.1 mol L-1 HClO4) before injection using an electronic micropipette on the BIA cell. The size effect of MWCNTs on electrochemical oxidation of pyrogallol was investigated and 3.5-fold increase in the amperometric sensitivity using the modified electrode with MWCNTs of shorter dimensions was obtained. This result was in agreement with cyclic voltammetry and electrochemical impedance spectroscopy measurements. After optimization of BIA parameters for the amperometric detection on the MWCNT-modified electrode, the proposed method presented a linear range from 0.3 to 1000 µmol L-1, detection limit of 0.013 µmol L-1, precision of 3%, and sample throughput of 240 h-1. Spiked biodiesel samples were analyzed and recovery values between 95-99% were obtained.
publishDate 2017
dc.date.none.fl_str_mv 2017-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017000901650
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017000901650
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21577/0103-5053.20160316
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.28 n.9 2017
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318179935059968