Resumo: Chloramphenicol was determinate by electrogenerated chemiluminescence coupled to FIA using Ru(bpy)3(2+) luminescent complex. Chloramphenicol cause a decrease in luminescence intensity from the ruthenium complex that is proportional to its concentration between 5 x 10-5 and 1 x 10-3 mol L-1. The relative standard deviation was estimated as £ 1.5 % for 1 x 10-4 mol L-1 chloramphenicol solution of 12 successive injections. The chloramphenicol was determined in tablets with success and the soluble components of the matrix did not interfere in the luminescent emission. Results obtained with the luminescent procedure were not statistically different from those obtained by UV-spectrophotometry at the 95 % confidence level.
id SBQ-2_928a3e01c788a8b858121b3e0854167b
oai_identifier_str oai:scielo:S0103-50532004000200004
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Determination of chloramphenicol in tablets by electrogenerated chemiluminescenceelectrogenerated chemiluminescenceFIAchloramphenicolpharmaceutical tabletsChloramphenicol was determinate by electrogenerated chemiluminescence coupled to FIA using Ru(bpy)3(2+) luminescent complex. Chloramphenicol cause a decrease in luminescence intensity from the ruthenium complex that is proportional to its concentration between 5 x 10-5 and 1 x 10-3 mol L-1. The relative standard deviation was estimated as £ 1.5 % for 1 x 10-4 mol L-1 chloramphenicol solution of 12 successive injections. The chloramphenicol was determined in tablets with success and the soluble components of the matrix did not interfere in the luminescent emission. Results obtained with the luminescent procedure were not statistically different from those obtained by UV-spectrophotometry at the 95 % confidence level.Sociedade Brasileira de Química2004-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000200004Journal of the Brazilian Chemical Society v.15 n.2 2004reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532004000200004info:eu-repo/semantics/openAccessLindino,Cleber AntonioBulhões,Luís Otávio S.eng2004-06-29T00:00:00Zoai:scielo:S0103-50532004000200004Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2004-06-29T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
title Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
spellingShingle Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
Lindino,Cleber Antonio
electrogenerated chemiluminescence
FIA
chloramphenicol
pharmaceutical tablets
title_short Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
title_full Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
title_fullStr Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
title_full_unstemmed Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
title_sort Determination of chloramphenicol in tablets by electrogenerated chemiluminescence
author Lindino,Cleber Antonio
author_facet Lindino,Cleber Antonio
Bulhões,Luís Otávio S.
author_role author
author2 Bulhões,Luís Otávio S.
author2_role author
dc.contributor.author.fl_str_mv Lindino,Cleber Antonio
Bulhões,Luís Otávio S.
dc.subject.por.fl_str_mv electrogenerated chemiluminescence
FIA
chloramphenicol
pharmaceutical tablets
topic electrogenerated chemiluminescence
FIA
chloramphenicol
pharmaceutical tablets
description Chloramphenicol was determinate by electrogenerated chemiluminescence coupled to FIA using Ru(bpy)3(2+) luminescent complex. Chloramphenicol cause a decrease in luminescence intensity from the ruthenium complex that is proportional to its concentration between 5 x 10-5 and 1 x 10-3 mol L-1. The relative standard deviation was estimated as £ 1.5 % for 1 x 10-4 mol L-1 chloramphenicol solution of 12 successive injections. The chloramphenicol was determined in tablets with success and the soluble components of the matrix did not interfere in the luminescent emission. Results obtained with the luminescent procedure were not statistically different from those obtained by UV-spectrophotometry at the 95 % confidence level.
publishDate 2004
dc.date.none.fl_str_mv 2004-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000200004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000200004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532004000200004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.15 n.2 2004
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318165694349312