Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets

Detalhes bibliográficos
Autor(a) principal: Cruz,Ariane P.
Data de Publicação: 2013
Outros Autores: Bertol,Charise D., Murakami,Fábio S., Pereira,Rafael N., Valente,Bruno R., Silva,Marcos A. S., Koester,Letícia S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Química Nova (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010
Resumo: A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²&gt;0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.
id SBQ-3_a12fbaf725f564e7bf72d55c878a808a
oai_identifier_str oai:scielo:S0100-40422013000300010
network_acronym_str SBQ-3
network_name_str Química Nova (Online)
repository_id_str
spelling Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tabletsdissolutionprimaquinematrix tabletsA simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²&gt;0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.Sociedade Brasileira de Química2013-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010Química Nova v.36 n.3 2013reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422013000300010info:eu-repo/semantics/openAccessCruz,Ariane P.Bertol,Charise D.Murakami,Fábio S.Pereira,Rafael N.Valente,Bruno R.Silva,Marcos A. S.Koester,Letícia S.eng2013-04-11T00:00:00Zoai:scielo:S0100-40422013000300010Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2013-04-11T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
title Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
spellingShingle Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
Cruz,Ariane P.
dissolution
primaquine
matrix tablets
title_short Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
title_full Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
title_fullStr Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
title_full_unstemmed Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
title_sort Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
author Cruz,Ariane P.
author_facet Cruz,Ariane P.
Bertol,Charise D.
Murakami,Fábio S.
Pereira,Rafael N.
Valente,Bruno R.
Silva,Marcos A. S.
Koester,Letícia S.
author_role author
author2 Bertol,Charise D.
Murakami,Fábio S.
Pereira,Rafael N.
Valente,Bruno R.
Silva,Marcos A. S.
Koester,Letícia S.
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Cruz,Ariane P.
Bertol,Charise D.
Murakami,Fábio S.
Pereira,Rafael N.
Valente,Bruno R.
Silva,Marcos A. S.
Koester,Letícia S.
dc.subject.por.fl_str_mv dissolution
primaquine
matrix tablets
topic dissolution
primaquine
matrix tablets
description A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²&gt;0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.
publishDate 2013
dc.date.none.fl_str_mv 2013-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-40422013000300010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Química Nova v.36 n.3 2013
reponame:Química Nova (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Química Nova (Online)
collection Química Nova (Online)
repository.name.fl_str_mv Química Nova (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv quimicanova@sbq.org.br
_version_ 1750318114685321216