Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings

Detalhes bibliográficos
Autor(a) principal: Lourenço,Danilo Budib
Data de Publicação: 2018
Outros Autores: Korkes,Fernando, Vetorazzo Filho,José Eduardo, Carramão,Silvia da Silva, Auge,Antônio Pedro Flores, Toledo,Luis Gustavo Morato de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Braz J Urol (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382018000300543
Resumo: ABSTRACT Surgical correction is the most efficient treatment for stress urinary incontinence (SUI), and transobturator sling (TO) has optimal results. The high cost of commercially available sling kits makes it difficult the access in most Brazilian public health services. Hand-made polypropylene slings, on the other hand, have been previously reported. The aim of the present study was to compare the effectiveness and safety of commercial vs. hand-made polypropylene mesh slings. Data from 57 women who underwent consecutive TO sling surgery to treat SUI were pros- pectively collected between 2012 and 2014, and divided in two groups for further compa- rison. In Group-1, 31 women underwent surgery with commercial slings. In Group-2, 26 women underwent hand-made polypropylene slings. Women were compared according to epidemiological data, perioperative evaluation, quality of life, urodynamic study, cure and complication rates. Results were objectively (stress test with Valsalva maneuver, with at least 200mL vesical repletion) and subjectively evaluated by the Patient Global Impression of Improvement(PGI-I), Visual Analog Scale (VAS) and ICIQ-SF. Success was defined as PGI-I, VAS and negative stress test. Group-1 (n=31) and Group-2 (n=26) had a mean age of 60 vs. 58years (p=0.386). All de- mographic data were similar. The mean VLPP was 75.6cmH2O vs. 76.6cmH2O (p=0.88). The mean follow-up was 24.3 vs. 21.5months (p=0.96). Success rates were 74.2% vs. 80.2% (p=0.556), with ICIQ-SF variation of 12.6 vs.15.5 (p=0.139) and PGI-I of 71% vs. 80% (p=0.225). There was only one major complication (urethrovaginal fistula in Group-1). In conclusion, handmade and commercial slings have similar effectiveness and safety. The manufacture technique has important key-points stated in the present manuscript.
id SBU-1_c6ce6ebe56a32f752df2385e6cc9f0ac
oai_identifier_str oai:scielo:S1677-55382018000300543
network_acronym_str SBU-1
network_name_str International Braz J Urol (Online)
repository_id_str
spelling Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slingsUrinary IncontinenceStressPelvic FloorSuburethral SlingsABSTRACT Surgical correction is the most efficient treatment for stress urinary incontinence (SUI), and transobturator sling (TO) has optimal results. The high cost of commercially available sling kits makes it difficult the access in most Brazilian public health services. Hand-made polypropylene slings, on the other hand, have been previously reported. The aim of the present study was to compare the effectiveness and safety of commercial vs. hand-made polypropylene mesh slings. Data from 57 women who underwent consecutive TO sling surgery to treat SUI were pros- pectively collected between 2012 and 2014, and divided in two groups for further compa- rison. In Group-1, 31 women underwent surgery with commercial slings. In Group-2, 26 women underwent hand-made polypropylene slings. Women were compared according to epidemiological data, perioperative evaluation, quality of life, urodynamic study, cure and complication rates. Results were objectively (stress test with Valsalva maneuver, with at least 200mL vesical repletion) and subjectively evaluated by the Patient Global Impression of Improvement(PGI-I), Visual Analog Scale (VAS) and ICIQ-SF. Success was defined as PGI-I, VAS and negative stress test. Group-1 (n=31) and Group-2 (n=26) had a mean age of 60 vs. 58years (p=0.386). All de- mographic data were similar. The mean VLPP was 75.6cmH2O vs. 76.6cmH2O (p=0.88). The mean follow-up was 24.3 vs. 21.5months (p=0.96). Success rates were 74.2% vs. 80.2% (p=0.556), with ICIQ-SF variation of 12.6 vs.15.5 (p=0.139) and PGI-I of 71% vs. 80% (p=0.225). There was only one major complication (urethrovaginal fistula in Group-1). In conclusion, handmade and commercial slings have similar effectiveness and safety. The manufacture technique has important key-points stated in the present manuscript.Sociedade Brasileira de Urologia2018-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382018000300543International braz j urol v.44 n.3 2018reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/s1677-5538.ibju.2017.0524info:eu-repo/semantics/openAccessLourenço,Danilo BudibKorkes,FernandoVetorazzo Filho,José EduardoCarramão,Silvia da SilvaAuge,Antônio Pedro FloresToledo,Luis Gustavo Morato deeng2018-06-22T00:00:00Zoai:scielo:S1677-55382018000300543Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2018-06-22T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false
dc.title.none.fl_str_mv Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
title Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
spellingShingle Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
Lourenço,Danilo Budib
Urinary Incontinence
Stress
Pelvic Floor
Suburethral Slings
title_short Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
title_full Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
title_fullStr Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
title_full_unstemmed Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
title_sort Functional outcomes and quality of life after transobturatory slings: hand - made vs. commercial slings
author Lourenço,Danilo Budib
author_facet Lourenço,Danilo Budib
Korkes,Fernando
Vetorazzo Filho,José Eduardo
Carramão,Silvia da Silva
Auge,Antônio Pedro Flores
Toledo,Luis Gustavo Morato de
author_role author
author2 Korkes,Fernando
Vetorazzo Filho,José Eduardo
Carramão,Silvia da Silva
Auge,Antônio Pedro Flores
Toledo,Luis Gustavo Morato de
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Lourenço,Danilo Budib
Korkes,Fernando
Vetorazzo Filho,José Eduardo
Carramão,Silvia da Silva
Auge,Antônio Pedro Flores
Toledo,Luis Gustavo Morato de
dc.subject.por.fl_str_mv Urinary Incontinence
Stress
Pelvic Floor
Suburethral Slings
topic Urinary Incontinence
Stress
Pelvic Floor
Suburethral Slings
description ABSTRACT Surgical correction is the most efficient treatment for stress urinary incontinence (SUI), and transobturator sling (TO) has optimal results. The high cost of commercially available sling kits makes it difficult the access in most Brazilian public health services. Hand-made polypropylene slings, on the other hand, have been previously reported. The aim of the present study was to compare the effectiveness and safety of commercial vs. hand-made polypropylene mesh slings. Data from 57 women who underwent consecutive TO sling surgery to treat SUI were pros- pectively collected between 2012 and 2014, and divided in two groups for further compa- rison. In Group-1, 31 women underwent surgery with commercial slings. In Group-2, 26 women underwent hand-made polypropylene slings. Women were compared according to epidemiological data, perioperative evaluation, quality of life, urodynamic study, cure and complication rates. Results were objectively (stress test with Valsalva maneuver, with at least 200mL vesical repletion) and subjectively evaluated by the Patient Global Impression of Improvement(PGI-I), Visual Analog Scale (VAS) and ICIQ-SF. Success was defined as PGI-I, VAS and negative stress test. Group-1 (n=31) and Group-2 (n=26) had a mean age of 60 vs. 58years (p=0.386). All de- mographic data were similar. The mean VLPP was 75.6cmH2O vs. 76.6cmH2O (p=0.88). The mean follow-up was 24.3 vs. 21.5months (p=0.96). Success rates were 74.2% vs. 80.2% (p=0.556), with ICIQ-SF variation of 12.6 vs.15.5 (p=0.139) and PGI-I of 71% vs. 80% (p=0.225). There was only one major complication (urethrovaginal fistula in Group-1). In conclusion, handmade and commercial slings have similar effectiveness and safety. The manufacture technique has important key-points stated in the present manuscript.
publishDate 2018
dc.date.none.fl_str_mv 2018-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382018000300543
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382018000300543
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1677-5538.ibju.2017.0524
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Urologia
publisher.none.fl_str_mv Sociedade Brasileira de Urologia
dc.source.none.fl_str_mv International braz j urol v.44 n.3 2018
reponame:International Braz J Urol (Online)
instname:Sociedade Brasileira de Urologia (SBU)
instacron:SBU
instname_str Sociedade Brasileira de Urologia (SBU)
instacron_str SBU
institution SBU
reponame_str International Braz J Urol (Online)
collection International Braz J Urol (Online)
repository.name.fl_str_mv International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)
repository.mail.fl_str_mv ||brazjurol@brazjurol.com.br
_version_ 1750318076244525056