Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle

Detalhes bibliográficos
Autor(a) principal: Palhão,M.P.
Data de Publicação: 2019
Outros Autores: Guimarães,C.R.B., Lima,J.F.J.F.M., Mendonça,M.R., Fernandes,C.A.C., Neves,J.P., Garcia,J.A.D., Gioso,M.M., Miglino,M.A., Viana,J.H.M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivo brasileiro de medicina veterinária e zootecnia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601909
Resumo: ABSTRACT The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG’s serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.
id UFMG-8_00111f3be2f21117b4103b0a57bd3f38
oai_identifier_str oai:scielo:S0102-09352019000601909
network_acronym_str UFMG-8
network_name_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository_id_str
spelling Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattlecolor dopplerPAGstimed embryo transferABSTRACT The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG’s serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.Universidade Federal de Minas Gerais, Escola de Veterinária2019-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601909Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.71 n.6 2019reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)instname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG10.1590/1678-4162-10698info:eu-repo/semantics/openAccessPalhão,M.P.Guimarães,C.R.B.Lima,J.F.J.F.M.Mendonça,M.R.Fernandes,C.A.C.Neves,J.P.Garcia,J.A.D.Gioso,M.M.Miglino,M.A.Viana,J.H.M.eng2019-12-10T00:00:00Zoai:scielo:S0102-09352019000601909Revistahttps://www.scielo.br/j/abmvz/PUBhttps://old.scielo.br/oai/scielo-oai.phpjournal@vet.ufmg.br||abmvz.artigo@abmvz.org.br1678-41620102-0935opendoar:2019-12-10T00:00Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
spellingShingle Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
Palhão,M.P.
color doppler
PAGs
timed embryo transfer
title_short Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_full Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_fullStr Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_full_unstemmed Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
title_sort Efficacy and limitations of different approaches to anticipate the diagnosis of pregnancy in cattle
author Palhão,M.P.
author_facet Palhão,M.P.
Guimarães,C.R.B.
Lima,J.F.J.F.M.
Mendonça,M.R.
Fernandes,C.A.C.
Neves,J.P.
Garcia,J.A.D.
Gioso,M.M.
Miglino,M.A.
Viana,J.H.M.
author_role author
author2 Guimarães,C.R.B.
Lima,J.F.J.F.M.
Mendonça,M.R.
Fernandes,C.A.C.
Neves,J.P.
Garcia,J.A.D.
Gioso,M.M.
Miglino,M.A.
Viana,J.H.M.
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Palhão,M.P.
Guimarães,C.R.B.
Lima,J.F.J.F.M.
Mendonça,M.R.
Fernandes,C.A.C.
Neves,J.P.
Garcia,J.A.D.
Gioso,M.M.
Miglino,M.A.
Viana,J.H.M.
dc.subject.por.fl_str_mv color doppler
PAGs
timed embryo transfer
topic color doppler
PAGs
timed embryo transfer
description ABSTRACT The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG’s serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.
publishDate 2019
dc.date.none.fl_str_mv 2019-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601909
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601909
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-4162-10698
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
dc.source.none.fl_str_mv Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.71 n.6 2019
reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
collection Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository.name.fl_str_mv Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv journal@vet.ufmg.br||abmvz.artigo@abmvz.org.br
_version_ 1750220893702848512