Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico

Detalhes bibliográficos
Autor(a) principal: Soares, Maria Rosangela
Data de Publicação: 2016
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFS
Texto Completo: https://ri.ufs.br/handle/riufs/5242
Resumo: This PhD thesis, addresses the issue of evaluation of cone beam computed tomography, CBCT, scanning protocols, was introduced in dental radiology at the end of the 1990s, and it quickly became a fundamental examination for various procedures. Its main characteristic, the difference of medical CT is the beam shape. This study aimed to calculate the absorbed dose in eight tissues / organs of the head and neck, and to estimate the effective dose in 13 protocols and two techniques (stitched FOV e single FOV) of 5 equipment of different manufacturers of cone beam CT. For that purpose, a female anthropomorphic phantom was used, representing a default woman, in which were inserted thermoluminescent dosimeters at several points, representing organs / tissues with weighting values presented in the standard ICRP 103. The results were evaluated by comparing the dose according to the purpose of the tomographic image. Among the results, there is a difference up to 325% in the effective dose in relation to protocols with the same image goal. In relation to the image acquisition technique, the stitched FOV technique resulted in an effective dose of 5.3 times greater than the single FOV technique for protocols with the same image goal. In the individual contribution, the salivary glands are responsible for 31% of the effective dose in CT exams. The remaining tissues have also a significant contribution, 36%. The results drew attention to the need of estimating the effective dose in different equipment and protocols of the market, besides the knowledge of the radiation parameters and equipment manufacturing engineering to obtain the image.
id UFS-2_6ac04eb121abc76ec62bba749e82911c
oai_identifier_str oai:ufs.br:riufs/5242
network_acronym_str UFS-2
network_name_str Repositório Institucional da UFS
repository_id_str
spelling Soares, Maria RosangelaMaia, Ana Figueiredohttp://lattes.cnpq.br/99639892706707062017-09-26T18:23:45Z2017-09-26T18:23:45Z2016-01-22Soares, Maria Rosangela. Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico. 2015. 120 f. Tese (Pós-Graduação em Física) - Universidade Federal de Sergipe, São Cristóvão, 2015.https://ri.ufs.br/handle/riufs/5242This PhD thesis, addresses the issue of evaluation of cone beam computed tomography, CBCT, scanning protocols, was introduced in dental radiology at the end of the 1990s, and it quickly became a fundamental examination for various procedures. Its main characteristic, the difference of medical CT is the beam shape. This study aimed to calculate the absorbed dose in eight tissues / organs of the head and neck, and to estimate the effective dose in 13 protocols and two techniques (stitched FOV e single FOV) of 5 equipment of different manufacturers of cone beam CT. For that purpose, a female anthropomorphic phantom was used, representing a default woman, in which were inserted thermoluminescent dosimeters at several points, representing organs / tissues with weighting values presented in the standard ICRP 103. The results were evaluated by comparing the dose according to the purpose of the tomographic image. Among the results, there is a difference up to 325% in the effective dose in relation to protocols with the same image goal. In relation to the image acquisition technique, the stitched FOV technique resulted in an effective dose of 5.3 times greater than the single FOV technique for protocols with the same image goal. In the individual contribution, the salivary glands are responsible for 31% of the effective dose in CT exams. The remaining tissues have also a significant contribution, 36%. The results drew attention to the need of estimating the effective dose in different equipment and protocols of the market, besides the knowledge of the radiation parameters and equipment manufacturing engineering to obtain the image.Na presente tese de doutoramento foi abordada a temática da avaliação de protocolos de exame de tomografia computadorizada de feixe cônico - TCFC, que foi iniciada na radiologia odontológica no fim da década de 1990 e rapidamente tornou-se um exame fundamental para diversos procedimentos. Sua principal característica, que a diferencia da tomografia computadorizada médica, é a forma do feixe. Assim, este estudo objetivou calcular a dose absorvida em 8 tecidos/órgãos da cabeça e pescoço e estimar a dose efetiva em 13 protocolos e duas técnicas (stitched FOV e single FOV) de 5 equipamentos diferentes fabricantes de tomografia computadorizada de feixe cônico. Para isto, foi utilizado um simulador antropomórfico feminino, representando uma mulher padrão, onde foram inseridos dosímetros termoluminescentes em diversos pontos, representando órgãos e tecidos com valores de ponderação apresentados na norma ICRP 103. Os resultados foram avaliados, comparando-se a dose de acordo com o objetivo da imagem tomográfica. Dentre os resultados, observou-se uma diferença de até 325 % de dose efetiva em relação a protocolos com o mesmo objetivo de imagem. Em relação à técnica de obtenção de imagem, a técnica stitched FOV resultou em uma dose efetiva até 5,3 vezes maior que a single FOV para protocolos com o mesmo objetivo de imagem. Na contribuição individual, as glândulas salivares são responsáveis por 31% da dose efetiva, nos exames tomográficos. Os tecidos restantes também apresentaram uma contribuição significativa, 36 %. Os resultados apontam a necessidade de se estimar a dose efetiva nos diversos equipamentos e protocolos presentes no mercado, além de conhecer os parâmetros de radiação e a engenharia de fabricação dos equipamentos para a obtenção da imagem.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESapplication/pdfporUniversidade Federal de SergipePós-Graduação em FísicaUFSBrasilFísicaTomografia computadorizada de feixe cônicoRadiaçãoDosimetriaTermoluminescênciaTomografia computadorizadaOdontologiaDose efetivaDose absorvidaDose no cristalinoProduto kerma ar-áreaEffective doseAbsorbed doseDose in the lensAir–kerma–areaCone Beam Computed Tomography (CBCT)CIENCIAS EXATAS E DA TERRA::FISICAAvaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônicoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSORIGINALMARIA_ROSANGELA_SOARES.pdfapplication/pdf2736768https://ri.ufs.br/jspui/bitstream/riufs/5242/1/MARIA_ROSANGELA_SOARES.pdf04300921277c7a08abeff9527d8cdd25MD51TEXTMARIA_ROSANGELA_SOARES.pdf.txtMARIA_ROSANGELA_SOARES.pdf.txtExtracted texttext/plain233097https://ri.ufs.br/jspui/bitstream/riufs/5242/2/MARIA_ROSANGELA_SOARES.pdf.txt03a1069abeaeba348a6ba6adea277cd2MD52THUMBNAILMARIA_ROSANGELA_SOARES.pdf.jpgMARIA_ROSANGELA_SOARES.pdf.jpgGenerated Thumbnailimage/jpeg1422https://ri.ufs.br/jspui/bitstream/riufs/5242/3/MARIA_ROSANGELA_SOARES.pdf.jpg62c92e704f0b5f469b371610cb31697bMD53riufs/52422020-04-14 16:49:49.551oai:ufs.br:riufs/5242Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2020-04-14T19:49:49Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false
dc.title.por.fl_str_mv Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
title Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
spellingShingle Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
Soares, Maria Rosangela
Física
Tomografia computadorizada de feixe cônico
Radiação
Dosimetria
Termoluminescência
Tomografia computadorizada
Odontologia
Dose efetiva
Dose absorvida
Dose no cristalino
Produto kerma ar-área
Effective dose
Absorbed dose
Dose in the lens
Air–kerma–area
Cone Beam Computed Tomography (CBCT)
CIENCIAS EXATAS E DA TERRA::FISICA
title_short Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
title_full Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
title_fullStr Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
title_full_unstemmed Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
title_sort Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico
author Soares, Maria Rosangela
author_facet Soares, Maria Rosangela
author_role author
dc.contributor.author.fl_str_mv Soares, Maria Rosangela
dc.contributor.advisor1.fl_str_mv Maia, Ana Figueiredo
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/9963989270670706
contributor_str_mv Maia, Ana Figueiredo
dc.subject.por.fl_str_mv Física
Tomografia computadorizada de feixe cônico
Radiação
Dosimetria
Termoluminescência
Tomografia computadorizada
Odontologia
Dose efetiva
Dose absorvida
Dose no cristalino
Produto kerma ar-área
Effective dose
Absorbed dose
Dose in the lens
Air–kerma–area
topic Física
Tomografia computadorizada de feixe cônico
Radiação
Dosimetria
Termoluminescência
Tomografia computadorizada
Odontologia
Dose efetiva
Dose absorvida
Dose no cristalino
Produto kerma ar-área
Effective dose
Absorbed dose
Dose in the lens
Air–kerma–area
Cone Beam Computed Tomography (CBCT)
CIENCIAS EXATAS E DA TERRA::FISICA
dc.subject.eng.fl_str_mv Cone Beam Computed Tomography (CBCT)
dc.subject.cnpq.fl_str_mv CIENCIAS EXATAS E DA TERRA::FISICA
description This PhD thesis, addresses the issue of evaluation of cone beam computed tomography, CBCT, scanning protocols, was introduced in dental radiology at the end of the 1990s, and it quickly became a fundamental examination for various procedures. Its main characteristic, the difference of medical CT is the beam shape. This study aimed to calculate the absorbed dose in eight tissues / organs of the head and neck, and to estimate the effective dose in 13 protocols and two techniques (stitched FOV e single FOV) of 5 equipment of different manufacturers of cone beam CT. For that purpose, a female anthropomorphic phantom was used, representing a default woman, in which were inserted thermoluminescent dosimeters at several points, representing organs / tissues with weighting values presented in the standard ICRP 103. The results were evaluated by comparing the dose according to the purpose of the tomographic image. Among the results, there is a difference up to 325% in the effective dose in relation to protocols with the same image goal. In relation to the image acquisition technique, the stitched FOV technique resulted in an effective dose of 5.3 times greater than the single FOV technique for protocols with the same image goal. In the individual contribution, the salivary glands are responsible for 31% of the effective dose in CT exams. The remaining tissues have also a significant contribution, 36%. The results drew attention to the need of estimating the effective dose in different equipment and protocols of the market, besides the knowledge of the radiation parameters and equipment manufacturing engineering to obtain the image.
publishDate 2016
dc.date.issued.fl_str_mv 2016-01-22
dc.date.accessioned.fl_str_mv 2017-09-26T18:23:45Z
dc.date.available.fl_str_mv 2017-09-26T18:23:45Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv Soares, Maria Rosangela. Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico. 2015. 120 f. Tese (Pós-Graduação em Física) - Universidade Federal de Sergipe, São Cristóvão, 2015.
dc.identifier.uri.fl_str_mv https://ri.ufs.br/handle/riufs/5242
identifier_str_mv Soares, Maria Rosangela. Avaliação dosimétrica de protocolos de exame de tomografia computadorizada de feixe cônico. 2015. 120 f. Tese (Pós-Graduação em Física) - Universidade Federal de Sergipe, São Cristóvão, 2015.
url https://ri.ufs.br/handle/riufs/5242
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Sergipe
dc.publisher.program.fl_str_mv Pós-Graduação em Física
dc.publisher.initials.fl_str_mv UFS
dc.publisher.country.fl_str_mv Brasil
publisher.none.fl_str_mv Universidade Federal de Sergipe
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFS
instname:Universidade Federal de Sergipe (UFS)
instacron:UFS
instname_str Universidade Federal de Sergipe (UFS)
instacron_str UFS
institution UFS
reponame_str Repositório Institucional da UFS
collection Repositório Institucional da UFS
bitstream.url.fl_str_mv https://ri.ufs.br/jspui/bitstream/riufs/5242/1/MARIA_ROSANGELA_SOARES.pdf
https://ri.ufs.br/jspui/bitstream/riufs/5242/2/MARIA_ROSANGELA_SOARES.pdf.txt
https://ri.ufs.br/jspui/bitstream/riufs/5242/3/MARIA_ROSANGELA_SOARES.pdf.jpg
bitstream.checksum.fl_str_mv 04300921277c7a08abeff9527d8cdd25
03a1069abeaeba348a6ba6adea277cd2
62c92e704f0b5f469b371610cb31697b
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)
repository.mail.fl_str_mv repositorio@academico.ufs.br
_version_ 1793350857496985600