Techniques of radioautography for medical and biological research
Autor(a) principal: | |
---|---|
Data de Publicação: | 1998 |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Medical and Biological Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X1998000200002 |
Resumo: | Standard techniques for radioautography used in biological and medical research can be classified into three categories, i.e., macroscopic radioautography, light microscopic radioautography and electron microscopic radioautography. The routine techniques used in these three procedures are described. With regard to macroscopic radioautography, whole body radioautography is a standard technique which employs freezing and cryosectioning and can demonstrate organ distributions of both soluble and insoluble compounds. In contrast, in light and electron microscopic radioautography, soluble and insoluble techniques are separated. In order to demonstrate insoluble labeled compounds, conventional chemical fixations such as formalin for light microscopy or buffered glutaraldehyde and osmium tetroxide for both light and electron microscopy followed by dehydration, embedding and wet-mounting applications of radioautographic emulsions can be used. For the demonstration of soluble labeled compounds, however, cryotechniques such as cryofixation, cryosectioning, freeze-drying, freeze-substitution followed by dry-sectioning and dry-mounting radioautography should be employed both for light and electron microscopy. The outlines of these techniques, which should be utilized in various fields of biological and medical research, are described in detail |
id |
ABDC-1_16b8d2ab9445d29c5568b3a0802d216b |
---|---|
oai_identifier_str |
oai:scielo:S0100-879X1998000200002 |
network_acronym_str |
ABDC-1 |
network_name_str |
Brazilian Journal of Medical and Biological Research |
repository_id_str |
|
spelling |
Techniques of radioautography for medical and biological researchmacroscopic radioautographylight microscopic radioautographyelectron microscopic radioautographymethodologyStandard techniques for radioautography used in biological and medical research can be classified into three categories, i.e., macroscopic radioautography, light microscopic radioautography and electron microscopic radioautography. The routine techniques used in these three procedures are described. With regard to macroscopic radioautography, whole body radioautography is a standard technique which employs freezing and cryosectioning and can demonstrate organ distributions of both soluble and insoluble compounds. In contrast, in light and electron microscopic radioautography, soluble and insoluble techniques are separated. In order to demonstrate insoluble labeled compounds, conventional chemical fixations such as formalin for light microscopy or buffered glutaraldehyde and osmium tetroxide for both light and electron microscopy followed by dehydration, embedding and wet-mounting applications of radioautographic emulsions can be used. For the demonstration of soluble labeled compounds, however, cryotechniques such as cryofixation, cryosectioning, freeze-drying, freeze-substitution followed by dry-sectioning and dry-mounting radioautography should be employed both for light and electron microscopy. The outlines of these techniques, which should be utilized in various fields of biological and medical research, are described in detailAssociação Brasileira de Divulgação Científica1998-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X1998000200002Brazilian Journal of Medical and Biological Research v.31 n.2 1998reponame:Brazilian Journal of Medical and Biological Researchinstname:Associação Brasileira de Divulgação Científica (ABDC)instacron:ABDC10.1590/S0100-879X1998000200002info:eu-repo/semantics/openAccessNagata,T.eng1998-10-07T00:00:00Zoai:scielo:S0100-879X1998000200002Revistahttps://www.bjournal.org/https://old.scielo.br/oai/scielo-oai.phpbjournal@terra.com.br||bjournal@terra.com.br1414-431X0100-879Xopendoar:1998-10-07T00:00Brazilian Journal of Medical and Biological Research - Associação Brasileira de Divulgação Científica (ABDC)false |
dc.title.none.fl_str_mv |
Techniques of radioautography for medical and biological research |
title |
Techniques of radioautography for medical and biological research |
spellingShingle |
Techniques of radioautography for medical and biological research Nagata,T. macroscopic radioautography light microscopic radioautography electron microscopic radioautography methodology |
title_short |
Techniques of radioautography for medical and biological research |
title_full |
Techniques of radioautography for medical and biological research |
title_fullStr |
Techniques of radioautography for medical and biological research |
title_full_unstemmed |
Techniques of radioautography for medical and biological research |
title_sort |
Techniques of radioautography for medical and biological research |
author |
Nagata,T. |
author_facet |
Nagata,T. |
author_role |
author |
dc.contributor.author.fl_str_mv |
Nagata,T. |
dc.subject.por.fl_str_mv |
macroscopic radioautography light microscopic radioautography electron microscopic radioautography methodology |
topic |
macroscopic radioautography light microscopic radioautography electron microscopic radioautography methodology |
description |
Standard techniques for radioautography used in biological and medical research can be classified into three categories, i.e., macroscopic radioautography, light microscopic radioautography and electron microscopic radioautography. The routine techniques used in these three procedures are described. With regard to macroscopic radioautography, whole body radioautography is a standard technique which employs freezing and cryosectioning and can demonstrate organ distributions of both soluble and insoluble compounds. In contrast, in light and electron microscopic radioautography, soluble and insoluble techniques are separated. In order to demonstrate insoluble labeled compounds, conventional chemical fixations such as formalin for light microscopy or buffered glutaraldehyde and osmium tetroxide for both light and electron microscopy followed by dehydration, embedding and wet-mounting applications of radioautographic emulsions can be used. For the demonstration of soluble labeled compounds, however, cryotechniques such as cryofixation, cryosectioning, freeze-drying, freeze-substitution followed by dry-sectioning and dry-mounting radioautography should be employed both for light and electron microscopy. The outlines of these techniques, which should be utilized in various fields of biological and medical research, are described in detail |
publishDate |
1998 |
dc.date.none.fl_str_mv |
1998-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X1998000200002 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X1998000200002 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-879X1998000200002 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Divulgação Científica |
publisher.none.fl_str_mv |
Associação Brasileira de Divulgação Científica |
dc.source.none.fl_str_mv |
Brazilian Journal of Medical and Biological Research v.31 n.2 1998 reponame:Brazilian Journal of Medical and Biological Research instname:Associação Brasileira de Divulgação Científica (ABDC) instacron:ABDC |
instname_str |
Associação Brasileira de Divulgação Científica (ABDC) |
instacron_str |
ABDC |
institution |
ABDC |
reponame_str |
Brazilian Journal of Medical and Biological Research |
collection |
Brazilian Journal of Medical and Biological Research |
repository.name.fl_str_mv |
Brazilian Journal of Medical and Biological Research - Associação Brasileira de Divulgação Científica (ABDC) |
repository.mail.fl_str_mv |
bjournal@terra.com.br||bjournal@terra.com.br |
_version_ |
1754302929174528000 |