CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS

Detalhes bibliográficos
Autor(a) principal: Perna,R. F.
Data de Publicação: 2015
Outros Autores: Cremasco,M. A., Santana,C. C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Chemical Engineering
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322015000400929
Resumo: Abstract Verapamil is a chiral drug that is marketed in its racemic form, but because of the pharmacological effects due to molecule’s chirality, one of the enantiomers is more potent, and the other exhibits different activities of therapeutic interest. The preparative separation of the verapamil enantiomers was performed using a continuous Varicol unit operated on a scale of 1 g/day. Amylose tris(3,5-dimethylphenylcarbamate) functioned as the stationary phase, and n-hexane/isopropanol/ethanol mixtures were used as the mobile phase. Diethylamine was used as the additive. The enantiomeric purities were 93.0% for S-(-)-verapamil and 92.0% for R-(+)-verapamil in the raffinate and extract streams, respectively. The unit provided productivities of 0.18 kg of raffinate per day per kg of adsorbent and 0.20 kg of extract per day per kg of adsorbent when using a feed concentration of 12.5 g L-1.
id ABEQ-1_f5bb70b5a24a792e711bb42daef210bd
oai_identifier_str oai:scielo:S0104-66322015000400929
network_acronym_str ABEQ-1
network_name_str Brazilian Journal of Chemical Engineering
repository_id_str
spelling CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESSContinuous chromatographyEnantiomersVaricolVerapamilAbstract Verapamil is a chiral drug that is marketed in its racemic form, but because of the pharmacological effects due to molecule’s chirality, one of the enantiomers is more potent, and the other exhibits different activities of therapeutic interest. The preparative separation of the verapamil enantiomers was performed using a continuous Varicol unit operated on a scale of 1 g/day. Amylose tris(3,5-dimethylphenylcarbamate) functioned as the stationary phase, and n-hexane/isopropanol/ethanol mixtures were used as the mobile phase. Diethylamine was used as the additive. The enantiomeric purities were 93.0% for S-(-)-verapamil and 92.0% for R-(+)-verapamil in the raffinate and extract streams, respectively. The unit provided productivities of 0.18 kg of raffinate per day per kg of adsorbent and 0.20 kg of extract per day per kg of adsorbent when using a feed concentration of 12.5 g L-1.Brazilian Society of Chemical Engineering2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322015000400929Brazilian Journal of Chemical Engineering v.32 n.4 2015reponame:Brazilian Journal of Chemical Engineeringinstname:Associação Brasileira de Engenharia Química (ABEQ)instacron:ABEQ10.1590/0104-6632.20150324s00003692info:eu-repo/semantics/openAccessPerna,R. F.Cremasco,M. A.Santana,C. C.eng2016-03-14T00:00:00Zoai:scielo:S0104-66322015000400929Revistahttps://www.scielo.br/j/bjce/https://old.scielo.br/oai/scielo-oai.phprgiudici@usp.br||rgiudici@usp.br1678-43830104-6632opendoar:2016-03-14T00:00Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ)false
dc.title.none.fl_str_mv CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
title CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
spellingShingle CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
Perna,R. F.
Continuous chromatography
Enantiomers
Varicol
Verapamil
title_short CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
title_full CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
title_fullStr CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
title_full_unstemmed CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
title_sort CHROMATOGRAPHIC SEPARATION OF VERAPAMIL RACEMATE USING A VARICOL CONTINUOUS MULTICOLUMN PROCESS
author Perna,R. F.
author_facet Perna,R. F.
Cremasco,M. A.
Santana,C. C.
author_role author
author2 Cremasco,M. A.
Santana,C. C.
author2_role author
author
dc.contributor.author.fl_str_mv Perna,R. F.
Cremasco,M. A.
Santana,C. C.
dc.subject.por.fl_str_mv Continuous chromatography
Enantiomers
Varicol
Verapamil
topic Continuous chromatography
Enantiomers
Varicol
Verapamil
description Abstract Verapamil is a chiral drug that is marketed in its racemic form, but because of the pharmacological effects due to molecule’s chirality, one of the enantiomers is more potent, and the other exhibits different activities of therapeutic interest. The preparative separation of the verapamil enantiomers was performed using a continuous Varicol unit operated on a scale of 1 g/day. Amylose tris(3,5-dimethylphenylcarbamate) functioned as the stationary phase, and n-hexane/isopropanol/ethanol mixtures were used as the mobile phase. Diethylamine was used as the additive. The enantiomeric purities were 93.0% for S-(-)-verapamil and 92.0% for R-(+)-verapamil in the raffinate and extract streams, respectively. The unit provided productivities of 0.18 kg of raffinate per day per kg of adsorbent and 0.20 kg of extract per day per kg of adsorbent when using a feed concentration of 12.5 g L-1.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322015000400929
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322015000400929
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0104-6632.20150324s00003692
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Brazilian Society of Chemical Engineering
publisher.none.fl_str_mv Brazilian Society of Chemical Engineering
dc.source.none.fl_str_mv Brazilian Journal of Chemical Engineering v.32 n.4 2015
reponame:Brazilian Journal of Chemical Engineering
instname:Associação Brasileira de Engenharia Química (ABEQ)
instacron:ABEQ
instname_str Associação Brasileira de Engenharia Química (ABEQ)
instacron_str ABEQ
institution ABEQ
reponame_str Brazilian Journal of Chemical Engineering
collection Brazilian Journal of Chemical Engineering
repository.name.fl_str_mv Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ)
repository.mail.fl_str_mv rgiudici@usp.br||rgiudici@usp.br
_version_ 1754213175015768064