Resumo: | OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation. |
id |
DPI-1_352eb9bb12067d411cb025cb0a3c9c6a |
---|---|
oai_identifier_str |
oai:scielo:S2176-94512015000400045 |
network_acronym_str |
DPI-1 |
network_name_str |
Dental Press Journal of Orthodontics |
repository_id_str |
|
spelling |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movementsOrthodontic bracketsBiomechanicsFatigueLaboratory automationOBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.Dental Press International2015-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000400045Dental Press Journal of Orthodontics v.20 n.4 2015reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2176-9451.20.4.045-050.oarinfo:eu-repo/semantics/openAccessCarneiro,Grace Kelly MartinsRoque,Juliano AlvesSegundo,Aguinaldo Silva GarcezSuzuki,Hideoeng2015-09-08T00:00:00Zoai:scielo:S2176-94512015000400045Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2015-09-08T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false |
dc.title.none.fl_str_mv |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements |
title |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements |
spellingShingle |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements Carneiro,Grace Kelly Martins Orthodontic brackets Biomechanics Fatigue Laboratory automation |
title_short |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements |
title_full |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements |
title_fullStr |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements |
title_full_unstemmed |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements |
title_sort |
Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements |
author |
Carneiro,Grace Kelly Martins |
author_facet |
Carneiro,Grace Kelly Martins Roque,Juliano Alves Segundo,Aguinaldo Silva Garcez Suzuki,Hideo |
author_role |
author |
author2 |
Roque,Juliano Alves Segundo,Aguinaldo Silva Garcez Suzuki,Hideo |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Carneiro,Grace Kelly Martins Roque,Juliano Alves Segundo,Aguinaldo Silva Garcez Suzuki,Hideo |
dc.subject.por.fl_str_mv |
Orthodontic brackets Biomechanics Fatigue Laboratory automation |
topic |
Orthodontic brackets Biomechanics Fatigue Laboratory automation |
description |
OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000400045 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000400045 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/2176-9451.20.4.045-050.oar |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Dental Press International |
publisher.none.fl_str_mv |
Dental Press International |
dc.source.none.fl_str_mv |
Dental Press Journal of Orthodontics v.20 n.4 2015 reponame:Dental Press Journal of Orthodontics instname:Dental Press International (DPI) instacron:DPI |
instname_str |
Dental Press International (DPI) |
instacron_str |
DPI |
institution |
DPI |
reponame_str |
Dental Press Journal of Orthodontics |
collection |
Dental Press Journal of Orthodontics |
repository.name.fl_str_mv |
Dental Press Journal of Orthodontics - Dental Press International (DPI) |
repository.mail.fl_str_mv |
artigos@dentalpress.com.br||davidnormando@hotmail.com |
_version_ |
1754122397272768512 |