Water quality of hemodialysis systems at Intensive Care Unit
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Vigilância Sanitária em Debate |
Texto Completo: | https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/205 |
Resumo: | There are rules and regulations for assessment of water quality services in ambulatory care unit and specific recommendations for the procedures performed in intensive care units (ICU) services. An exploratory study was conducted at hemodialysis equipment in ICU in a Southern Brazil city. Water samples were directly collected from the network public supply and from post-reverse osmosis associated with hemodialysis equipaments, monthly from January to June 2011. Mass spectrometry technique (quadrupolar type), associated with a source of inductive coupling plasma (ICP/MS) was applied to measure water trace metals levels. Bacteriological analyzes were performed to search for he-terotrophic bacteria. Data showed that the metal concentrations in the purified water of hemodialysis centers did not exceed legal standards. The bacteriological analysis of water for hemodialysis systems resulted as < 200 CFU/mL, according to legal limits in all evaluated months, with an exception on February. The results corroborate the fact that maintenance and precaution with the hemodialysis water are being effective. The avoidance of complications arising from chemical or microbiologic water contaminants, in ICU requires a constant attention, since patients conditions are different from those found in outpatient care. |
id |
FIOCRUZ-9_5a03c6bc78d9635eda072a0e2ecb8a71 |
---|---|
oai_identifier_str |
oai:ojs.visaemdebate.incqs.fiocruz.br:article/205 |
network_acronym_str |
FIOCRUZ-9 |
network_name_str |
Vigilância Sanitária em Debate |
repository_id_str |
|
spelling |
Water quality of hemodialysis systems at Intensive Care UnitQualidade da água utilizada para equipamentos de hemodiálise em Unidade de Terapia IntensivaWaterMetalBacteriological AnalysisHemodialysisÁguaMetaisAnálise BacteriológicaHemodiáliseThere are rules and regulations for assessment of water quality services in ambulatory care unit and specific recommendations for the procedures performed in intensive care units (ICU) services. An exploratory study was conducted at hemodialysis equipment in ICU in a Southern Brazil city. Water samples were directly collected from the network public supply and from post-reverse osmosis associated with hemodialysis equipaments, monthly from January to June 2011. Mass spectrometry technique (quadrupolar type), associated with a source of inductive coupling plasma (ICP/MS) was applied to measure water trace metals levels. Bacteriological analyzes were performed to search for he-terotrophic bacteria. Data showed that the metal concentrations in the purified water of hemodialysis centers did not exceed legal standards. The bacteriological analysis of water for hemodialysis systems resulted as < 200 CFU/mL, according to legal limits in all evaluated months, with an exception on February. The results corroborate the fact that maintenance and precaution with the hemodialysis water are being effective. The avoidance of complications arising from chemical or microbiologic water contaminants, in ICU requires a constant attention, since patients conditions are different from those found in outpatient care.Existem critérios e regulamentos para a avaliação da qualidade da água em serviços de unidade de terapia ambulatorial e recomendações específicas para os procedimentos realizados em unidades de terapia intensiva (UTI). Um estudo exploratório foi conduzido em equipamentos de hemodiálise em UTI, em uma cidade do Sul do Brasil. Amostras de água foram coletadas da rede de abastecimento público e pós-osmose reversa associa-da a dois aparelhos de hemodiálise, entre janeiro e junho de 2011. Espectrometria de emissão óptica com fonte de plasma indutivamente acoplado (ICP OES) foi utilizada para análise de metais em níveis de traços. Análises bacteriológicas foram realizadas para pesquisa de bactérias heterotróficas. Os dados obtidos mostraram que as concentrações dos metais não excederam os limites estabelecidos pela legislação. A análise bacterioló-gica da água para hemodiálise resultou em contagem inferior a 200 UFC/mL, em todos os meses avaliados, com exceção do mês de fevereiro. Os resultados obtidos corroboram o fato de que a manutenção e os cuidados necessários com a água para o tratamento dialítico têm sido efetivos. A prevenção de complicações decorrentes de contaminantes químicos ou microbiológicos na água para hemodiálise em UTI requer uma atenção constante, uma vez que as condições dos pacientes são diferentes daquelas encontradas em atendimento ambulatorial.Instituto Nacional de Controle de Qualidade em Saúde2014-08-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Peer-reviewed article""Artículo revisado por pares""Artigo avaliado pelos pares"application/pdfhttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/20510.3395/vd.v2n3.205Health Surveillance under Debate: Society, Science & Technology ; Vol. 2 No. 3 (2014): August; 37-43Vigilancia en Salud en Debate: Sociedad, Ciencia y Tecnología; Vol. 2 Núm. 3 (2014): Agosto; 37-43Vigil Sanit Debate, Rio de Janeiro; v. 2 n. 3 (2014): Agosto; 37-432317-269Xreponame:Vigilância Sanitária em Debateinstname:Fundação Oswaldo Cruz (FIOCRUZ)instacron:FIOCRUZporhttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/205/133Copyright (c) 2014 Vigilância Sanitária em Debate: Sociedade, Ciência & Tecnologia (Health Surveillance under Debate: Society, Science & Technology) – Visa em Debatehttps://creativecommons.org/licenses/by-nc-nd/4.0info:eu-repo/semantics/openAccessMossini, Simone Aparecida GaleraniTomoike, CarolineKohiyama, Cássia YumieYamada, Sérgio SeijiSilva, Sandra Regina BinGarcia, Lourdes BotelhoTognim, Maria Cristina BronharoBando, ÉrikaNishiyama, Paula2023-06-27T14:57:33Zoai:ojs.visaemdebate.incqs.fiocruz.br:article/205Revistahttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebatePUBhttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/oaiincqs.visaemdebate@fiocruz.br || gisele.neves@fiocruz.br2317-269X2317-269Xopendoar:2023-06-27T14:57:33Vigilância Sanitária em Debate - Fundação Oswaldo Cruz (FIOCRUZ)false |
dc.title.none.fl_str_mv |
Water quality of hemodialysis systems at Intensive Care Unit Qualidade da água utilizada para equipamentos de hemodiálise em Unidade de Terapia Intensiva |
title |
Water quality of hemodialysis systems at Intensive Care Unit |
spellingShingle |
Water quality of hemodialysis systems at Intensive Care Unit Mossini, Simone Aparecida Galerani Water Metal Bacteriological Analysis Hemodialysis Água Metais Análise Bacteriológica Hemodiálise |
title_short |
Water quality of hemodialysis systems at Intensive Care Unit |
title_full |
Water quality of hemodialysis systems at Intensive Care Unit |
title_fullStr |
Water quality of hemodialysis systems at Intensive Care Unit |
title_full_unstemmed |
Water quality of hemodialysis systems at Intensive Care Unit |
title_sort |
Water quality of hemodialysis systems at Intensive Care Unit |
author |
Mossini, Simone Aparecida Galerani |
author_facet |
Mossini, Simone Aparecida Galerani Tomoike, Caroline Kohiyama, Cássia Yumie Yamada, Sérgio Seiji Silva, Sandra Regina Bin Garcia, Lourdes Botelho Tognim, Maria Cristina Bronharo Bando, Érika Nishiyama, Paula |
author_role |
author |
author2 |
Tomoike, Caroline Kohiyama, Cássia Yumie Yamada, Sérgio Seiji Silva, Sandra Regina Bin Garcia, Lourdes Botelho Tognim, Maria Cristina Bronharo Bando, Érika Nishiyama, Paula |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Mossini, Simone Aparecida Galerani Tomoike, Caroline Kohiyama, Cássia Yumie Yamada, Sérgio Seiji Silva, Sandra Regina Bin Garcia, Lourdes Botelho Tognim, Maria Cristina Bronharo Bando, Érika Nishiyama, Paula |
dc.subject.por.fl_str_mv |
Water Metal Bacteriological Analysis Hemodialysis Água Metais Análise Bacteriológica Hemodiálise |
topic |
Water Metal Bacteriological Analysis Hemodialysis Água Metais Análise Bacteriológica Hemodiálise |
description |
There are rules and regulations for assessment of water quality services in ambulatory care unit and specific recommendations for the procedures performed in intensive care units (ICU) services. An exploratory study was conducted at hemodialysis equipment in ICU in a Southern Brazil city. Water samples were directly collected from the network public supply and from post-reverse osmosis associated with hemodialysis equipaments, monthly from January to June 2011. Mass spectrometry technique (quadrupolar type), associated with a source of inductive coupling plasma (ICP/MS) was applied to measure water trace metals levels. Bacteriological analyzes were performed to search for he-terotrophic bacteria. Data showed that the metal concentrations in the purified water of hemodialysis centers did not exceed legal standards. The bacteriological analysis of water for hemodialysis systems resulted as < 200 CFU/mL, according to legal limits in all evaluated months, with an exception on February. The results corroborate the fact that maintenance and precaution with the hemodialysis water are being effective. The avoidance of complications arising from chemical or microbiologic water contaminants, in ICU requires a constant attention, since patients conditions are different from those found in outpatient care. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-08-04 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion "Peer-reviewed article" "Artículo revisado por pares" "Artigo avaliado pelos pares" |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/205 10.3395/vd.v2n3.205 |
url |
https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/205 |
identifier_str_mv |
10.3395/vd.v2n3.205 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/205/133 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Instituto Nacional de Controle de Qualidade em Saúde |
publisher.none.fl_str_mv |
Instituto Nacional de Controle de Qualidade em Saúde |
dc.source.none.fl_str_mv |
Health Surveillance under Debate: Society, Science & Technology ; Vol. 2 No. 3 (2014): August; 37-43 Vigilancia en Salud en Debate: Sociedad, Ciencia y Tecnología; Vol. 2 Núm. 3 (2014): Agosto; 37-43 Vigil Sanit Debate, Rio de Janeiro; v. 2 n. 3 (2014): Agosto; 37-43 2317-269X reponame:Vigilância Sanitária em Debate instname:Fundação Oswaldo Cruz (FIOCRUZ) instacron:FIOCRUZ |
instname_str |
Fundação Oswaldo Cruz (FIOCRUZ) |
instacron_str |
FIOCRUZ |
institution |
FIOCRUZ |
reponame_str |
Vigilância Sanitária em Debate |
collection |
Vigilância Sanitária em Debate |
repository.name.fl_str_mv |
Vigilância Sanitária em Debate - Fundação Oswaldo Cruz (FIOCRUZ) |
repository.mail.fl_str_mv |
incqs.visaemdebate@fiocruz.br || gisele.neves@fiocruz.br |
_version_ |
1797042043463139328 |