Reliability of FEA on the Results of Mechanical Properties of Materials

Detalhes bibliográficos
Autor(a) principal: Gomes,Erica Alves
Data de Publicação: 2015
Outros Autores: Diana,Hugo Henrique, Oliveira,Juliana Santos, Silva-Sousa,Yara Teresinha Corrêa, Faria,Adriana Cláudia Lapria, Ribeiro,Ricardo Faria
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600667
Resumo: The present study evaluated the reliability of FEA on the results of different mechanical properties (E and v) of materials. Two 3D models of a maxillary canine with endodontic treatment, intracanal post, composite resin core and restored with porcelain-fused-to-metal crown were generated according to micro-CT images. Two groups with different E and ν values for porcelain, metal coping alloy, resin cement and composite resin were established. The materials' properties for group GL were based on literature data, while for group GIE the impulse excitation technique was used. A load of 180 N was applied at 45° on the incisal third of the lingual surface of the canine tooth. All models were supported by the periodontal ligament (x=y=z=0). The von Mises stress (VMS) was calculated. The stress values revealed differences between the groups for both VMS distribution and value. The porcelain (GL: 5.966 MPa; GIE: 7.478 MPa), metal coping (GL: 3.811 MPa; GIE: 0.973 MPa) and core (GL: 4.771 MPa; GIE: 0.026 MPa) were significantly affected. In conclusion, this study showed that the determination of mechanical properties (E and ν) of materials is essential for the reliability on the results of FEA.
id FUNORP-1_2d6925c03b96953700c9260e69a4bd8d
oai_identifier_str oai:scielo:S0103-64402015000600667
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Reliability of FEA on the Results of Mechanical Properties of Materialsfinite element analysismechanical propertiesresearchThe present study evaluated the reliability of FEA on the results of different mechanical properties (E and v) of materials. Two 3D models of a maxillary canine with endodontic treatment, intracanal post, composite resin core and restored with porcelain-fused-to-metal crown were generated according to micro-CT images. Two groups with different E and ν values for porcelain, metal coping alloy, resin cement and composite resin were established. The materials' properties for group GL were based on literature data, while for group GIE the impulse excitation technique was used. A load of 180 N was applied at 45° on the incisal third of the lingual surface of the canine tooth. All models were supported by the periodontal ligament (x=y=z=0). The von Mises stress (VMS) was calculated. The stress values revealed differences between the groups for both VMS distribution and value. The porcelain (GL: 5.966 MPa; GIE: 7.478 MPa), metal coping (GL: 3.811 MPa; GIE: 0.973 MPa) and core (GL: 4.771 MPa; GIE: 0.026 MPa) were significantly affected. In conclusion, this study showed that the determination of mechanical properties (E and ν) of materials is essential for the reliability on the results of FEA.Fundação Odontológica de Ribeirão Preto2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600667Brazilian Dental Journal v.26 n.6 2015reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201300639info:eu-repo/semantics/openAccessGomes,Erica AlvesDiana,Hugo HenriqueOliveira,Juliana SantosSilva-Sousa,Yara Teresinha CorrêaFaria,Adriana Cláudia LapriaRibeiro,Ricardo Fariaeng2015-12-22T00:00:00Zoai:scielo:S0103-64402015000600667Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2015-12-22T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Reliability of FEA on the Results of Mechanical Properties of Materials
title Reliability of FEA on the Results of Mechanical Properties of Materials
spellingShingle Reliability of FEA on the Results of Mechanical Properties of Materials
Gomes,Erica Alves
finite element analysis
mechanical properties
research
title_short Reliability of FEA on the Results of Mechanical Properties of Materials
title_full Reliability of FEA on the Results of Mechanical Properties of Materials
title_fullStr Reliability of FEA on the Results of Mechanical Properties of Materials
title_full_unstemmed Reliability of FEA on the Results of Mechanical Properties of Materials
title_sort Reliability of FEA on the Results of Mechanical Properties of Materials
author Gomes,Erica Alves
author_facet Gomes,Erica Alves
Diana,Hugo Henrique
Oliveira,Juliana Santos
Silva-Sousa,Yara Teresinha Corrêa
Faria,Adriana Cláudia Lapria
Ribeiro,Ricardo Faria
author_role author
author2 Diana,Hugo Henrique
Oliveira,Juliana Santos
Silva-Sousa,Yara Teresinha Corrêa
Faria,Adriana Cláudia Lapria
Ribeiro,Ricardo Faria
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Gomes,Erica Alves
Diana,Hugo Henrique
Oliveira,Juliana Santos
Silva-Sousa,Yara Teresinha Corrêa
Faria,Adriana Cláudia Lapria
Ribeiro,Ricardo Faria
dc.subject.por.fl_str_mv finite element analysis
mechanical properties
research
topic finite element analysis
mechanical properties
research
description The present study evaluated the reliability of FEA on the results of different mechanical properties (E and v) of materials. Two 3D models of a maxillary canine with endodontic treatment, intracanal post, composite resin core and restored with porcelain-fused-to-metal crown were generated according to micro-CT images. Two groups with different E and ν values for porcelain, metal coping alloy, resin cement and composite resin were established. The materials' properties for group GL were based on literature data, while for group GIE the impulse excitation technique was used. A load of 180 N was applied at 45° on the incisal third of the lingual surface of the canine tooth. All models were supported by the periodontal ligament (x=y=z=0). The von Mises stress (VMS) was calculated. The stress values revealed differences between the groups for both VMS distribution and value. The porcelain (GL: 5.966 MPa; GIE: 7.478 MPa), metal coping (GL: 3.811 MPa; GIE: 0.973 MPa) and core (GL: 4.771 MPa; GIE: 0.026 MPa) were significantly affected. In conclusion, this study showed that the determination of mechanical properties (E and ν) of materials is essential for the reliability on the results of FEA.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600667
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600667
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440201300639
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.26 n.6 2015
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204093946003456