Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength

Detalhes bibliográficos
Autor(a) principal: Souza-Gabriel,Aline Evangelista
Data de Publicação: 2011
Outros Autores: Vitussi,Lilian Oliveira Cambaúva, Milani,Camila, Alfredo,Edson, Messias,Danielle Cristine Furtado, Silva-Sousa,Yara Teresinha Correa
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400010
Resumo: This study assessed the effect of bleaching protocols with 38% hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukey's test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p&gt;0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p&gt;0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p<0.05). The restorative procedure of intracoronary dentin bleached with 38% HP with or without the use of light source should be performed after at least 10 days after the bleaching treatment.
id FUNORP-1_6a7f85f78780c3e31e760c12408ceace
oai_identifier_str oai:scielo:S0103-64402011000400010
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strengthshear bond strengthhydrogen peroxidebleachingpost-time bleachingThis study assessed the effect of bleaching protocols with 38% hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukey's test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p&gt;0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p&gt;0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p<0.05). The restorative procedure of intracoronary dentin bleached with 38% HP with or without the use of light source should be performed after at least 10 days after the bleaching treatment.Fundação Odontológica de Ribeirão Preto2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400010Brazilian Dental Journal v.22 n.4 2011reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402011000400010info:eu-repo/semantics/openAccessSouza-Gabriel,Aline EvangelistaVitussi,Lilian Oliveira CambaúvaMilani,CamilaAlfredo,EdsonMessias,Danielle Cristine FurtadoSilva-Sousa,Yara Teresinha Correaeng2011-08-12T00:00:00Zoai:scielo:S0103-64402011000400010Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2011-08-12T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
title Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
spellingShingle Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
Souza-Gabriel,Aline Evangelista
shear bond strength
hydrogen peroxide
bleaching
post-time bleaching
title_short Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
title_full Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
title_fullStr Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
title_full_unstemmed Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
title_sort Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength
author Souza-Gabriel,Aline Evangelista
author_facet Souza-Gabriel,Aline Evangelista
Vitussi,Lilian Oliveira Cambaúva
Milani,Camila
Alfredo,Edson
Messias,Danielle Cristine Furtado
Silva-Sousa,Yara Teresinha Correa
author_role author
author2 Vitussi,Lilian Oliveira Cambaúva
Milani,Camila
Alfredo,Edson
Messias,Danielle Cristine Furtado
Silva-Sousa,Yara Teresinha Correa
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Souza-Gabriel,Aline Evangelista
Vitussi,Lilian Oliveira Cambaúva
Milani,Camila
Alfredo,Edson
Messias,Danielle Cristine Furtado
Silva-Sousa,Yara Teresinha Correa
dc.subject.por.fl_str_mv shear bond strength
hydrogen peroxide
bleaching
post-time bleaching
topic shear bond strength
hydrogen peroxide
bleaching
post-time bleaching
description This study assessed the effect of bleaching protocols with 38% hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukey's test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p&gt;0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p&gt;0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p<0.05). The restorative procedure of intracoronary dentin bleached with 38% HP with or without the use of light source should be performed after at least 10 days after the bleaching treatment.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402011000400010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.22 n.4 2011
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204091804811264