Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT

Detalhes bibliográficos
Autor(a) principal: Silva,B. V.
Data de Publicação: 2014
Outros Autores: Barbosa,M. P., Silva Filho,L. C. P., Lorrain,M. S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952014000500008
Resumo: The scope of this research investigates the feasibility to use steel-concrete bond tests for estimating the compressive strength of concrete to supplementary use it in the quality control of reinforced concrete. Lorrain and Barbosa (2008)[1] and Lorrain et al. (2011)[2] justify the use of a modified bond test, called APULOT, to estimate the compressive strength of concrete, thereby increasing the possibilities for the technological control of reinforced concrete at construction sites. They propose an adaptation of the traditional pull-out test (POT) method, standardized by CEB/FIP RC6:1983[3], as this is a low complexity test with the advantage of reduced costs. The use of the APULOT test as a technological control test of concrete at construction sites requires determining a standard and also adapting it from the experimental laboratory practice to the field. The first part of this work evaluated the potential to perform compressive strength estimates from the bond strength data obtained by the POT test. The second part of this paper will present and discuss the test results achieved by the APULOT method. Two concrete compositions of different classes (25 MPa and 45 MPa) were tested at 3, 7 and 28 days. Ribbed bar specimens (nominal diameters of 8, 10 and 12.5 mm) were also used in the preparation stage of the specimens, totaling 144 APULOT tests. The results show that under standard test conditions, the correlation between the maximum bond strength and the compressive strength of concrete is satisfactory at all ages tested, corroborating the objective of consolidating this test as a complementary alternative for controlling the quality of reinforced concrete.
id IBRACON-1_043b1d85f7242b1e34921ee72701dca2
oai_identifier_str oai:scielo:S1983-41952014000500008
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOTbond steel-concretepull-outAPULOTcompressive strength of concreteThe scope of this research investigates the feasibility to use steel-concrete bond tests for estimating the compressive strength of concrete to supplementary use it in the quality control of reinforced concrete. Lorrain and Barbosa (2008)[1] and Lorrain et al. (2011)[2] justify the use of a modified bond test, called APULOT, to estimate the compressive strength of concrete, thereby increasing the possibilities for the technological control of reinforced concrete at construction sites. They propose an adaptation of the traditional pull-out test (POT) method, standardized by CEB/FIP RC6:1983[3], as this is a low complexity test with the advantage of reduced costs. The use of the APULOT test as a technological control test of concrete at construction sites requires determining a standard and also adapting it from the experimental laboratory practice to the field. The first part of this work evaluated the potential to perform compressive strength estimates from the bond strength data obtained by the POT test. The second part of this paper will present and discuss the test results achieved by the APULOT method. Two concrete compositions of different classes (25 MPa and 45 MPa) were tested at 3, 7 and 28 days. Ribbed bar specimens (nominal diameters of 8, 10 and 12.5 mm) were also used in the preparation stage of the specimens, totaling 144 APULOT tests. The results show that under standard test conditions, the correlation between the maximum bond strength and the compressive strength of concrete is satisfactory at all ages tested, corroborating the objective of consolidating this test as a complementary alternative for controlling the quality of reinforced concrete.IBRACON - Instituto Brasileiro do Concreto2014-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952014000500008Revista IBRACON de Estruturas e Materiais v.7 n.5 2014reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/S1983-41952014000500008info:eu-repo/semantics/openAccessSilva,B. V.Barbosa,M. P.Silva Filho,L. C. P.Lorrain,M. S.eng2014-10-27T00:00:00Zoai:scielo:S1983-41952014000500008Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2014-10-27T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
title Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
spellingShingle Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
Silva,B. V.
bond steel-concrete
pull-out
APULOT
compressive strength of concrete
title_short Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
title_full Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
title_fullStr Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
title_full_unstemmed Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
title_sort Experimental investigation on the use of steel-concrete bond tests for estimating axial compressive strength of concrete. Part 2: APULOT
author Silva,B. V.
author_facet Silva,B. V.
Barbosa,M. P.
Silva Filho,L. C. P.
Lorrain,M. S.
author_role author
author2 Barbosa,M. P.
Silva Filho,L. C. P.
Lorrain,M. S.
author2_role author
author
author
dc.contributor.author.fl_str_mv Silva,B. V.
Barbosa,M. P.
Silva Filho,L. C. P.
Lorrain,M. S.
dc.subject.por.fl_str_mv bond steel-concrete
pull-out
APULOT
compressive strength of concrete
topic bond steel-concrete
pull-out
APULOT
compressive strength of concrete
description The scope of this research investigates the feasibility to use steel-concrete bond tests for estimating the compressive strength of concrete to supplementary use it in the quality control of reinforced concrete. Lorrain and Barbosa (2008)[1] and Lorrain et al. (2011)[2] justify the use of a modified bond test, called APULOT, to estimate the compressive strength of concrete, thereby increasing the possibilities for the technological control of reinforced concrete at construction sites. They propose an adaptation of the traditional pull-out test (POT) method, standardized by CEB/FIP RC6:1983[3], as this is a low complexity test with the advantage of reduced costs. The use of the APULOT test as a technological control test of concrete at construction sites requires determining a standard and also adapting it from the experimental laboratory practice to the field. The first part of this work evaluated the potential to perform compressive strength estimates from the bond strength data obtained by the POT test. The second part of this paper will present and discuss the test results achieved by the APULOT method. Two concrete compositions of different classes (25 MPa and 45 MPa) were tested at 3, 7 and 28 days. Ribbed bar specimens (nominal diameters of 8, 10 and 12.5 mm) were also used in the preparation stage of the specimens, totaling 144 APULOT tests. The results show that under standard test conditions, the correlation between the maximum bond strength and the compressive strength of concrete is satisfactory at all ages tested, corroborating the objective of consolidating this test as a complementary alternative for controlling the quality of reinforced concrete.
publishDate 2014
dc.date.none.fl_str_mv 2014-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952014000500008
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952014000500008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1983-41952014000500008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.7 n.5 2014
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193604771840000