A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico

Detalhes bibliográficos
Autor(a) principal: Felix, Rafael Perdomo
Data de Publicação: 2015
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da PUC_RS
Texto Completo: http://tede2.pucrs.br/tede2/handle/tede/6041
Resumo: Imaging exams performed in areas with the presence of metallic materials such as dental implants can decrease the accuracy of the exams due to metallic artifacts production generated in the peri-implant region. A sample of 21 dental implants placed in 10 patients with Branemark protocol prostheses was evaluated in the periimplant area in image exams of the post-surgery control using periapical radiography (paralleling technique), panoramic radiography and cone-beam computed tomography (CBCT). The radiographic density of different areas bounded near the dental implants were calculated and compared considering their locations and the imaging exams using the software ImageJ. Regarding the different imaging exams, the CBCT showed significant differences between the measured areas (p<0.001), while in periapical (p=0.430) and panoramic (p=0.149) radiographs did not occur significant difference between the gray mean values in these areas. Comparing the areas in the three exams it was observed larger values next to the implants in all exams: CBCT (126.20 and 127.44) panoramic radiography (106.51 and 106.09) and periapical radiography (120.32). The more distant areas and the areas closest to neighboring implants had significant different values in the two reconstructed images of CBCT when compared to the panoramic and periapical radiographs. The interference of dental implants in acquiring radiographic and tomographic exams was confirmed by altered radiographic density mean values in the peri-implant area. Comparing the three exams it was noticed that the CBCT image showed the most significant interference of the dental implants.
id P_RS_b78ba47539f09071cf8e5e145831f870
oai_identifier_str oai:tede2.pucrs.br:tede/6041
network_acronym_str P_RS
network_name_str Biblioteca Digital de Teses e Dissertações da PUC_RS
repository_id_str
spelling Rockenbach, Maria Ivete Bolzanhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4779793A9Shinkai, Rosemary Sadami Araihttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4765007P0008.026.190-61http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4242392H0Felix, Rafael Perdomo2015-05-21T20:19:16Z2015-03-30http://tede2.pucrs.br/tede2/handle/tede/6041Imaging exams performed in areas with the presence of metallic materials such as dental implants can decrease the accuracy of the exams due to metallic artifacts production generated in the peri-implant region. A sample of 21 dental implants placed in 10 patients with Branemark protocol prostheses was evaluated in the periimplant area in image exams of the post-surgery control using periapical radiography (paralleling technique), panoramic radiography and cone-beam computed tomography (CBCT). The radiographic density of different areas bounded near the dental implants were calculated and compared considering their locations and the imaging exams using the software ImageJ. Regarding the different imaging exams, the CBCT showed significant differences between the measured areas (p<0.001), while in periapical (p=0.430) and panoramic (p=0.149) radiographs did not occur significant difference between the gray mean values in these areas. Comparing the areas in the three exams it was observed larger values next to the implants in all exams: CBCT (126.20 and 127.44) panoramic radiography (106.51 and 106.09) and periapical radiography (120.32). The more distant areas and the areas closest to neighboring implants had significant different values in the two reconstructed images of CBCT when compared to the panoramic and periapical radiographs. The interference of dental implants in acquiring radiographic and tomographic exams was confirmed by altered radiographic density mean values in the peri-implant area. Comparing the three exams it was noticed that the CBCT image showed the most significant interference of the dental implants.Os exames por imagem realizados em áreas que apresentam materiais metálicos, como implantes dentários, podem ter sua qualidade prejudicada devido à produção de artefatos metálicos gerados na região peri-implantar. Uma amostra de 21 implantes dentários, em 10 pacientes com próteses do tipo protocolo Branemark, foi avaliada com o objetivo de comparar as densidades radiográficas na região periimplantar em exames de imagens de controle pós-operatório com radiografia periapical (técnica do paralelismo), radiografia panorâmica e tomografia computadorizada de feixe cônico. Os valores médios de densidade em áreas delimitadas próximas aos implantes dentários foram calculados e comparados, de acordo com suas localizações, e entre os exames de imagens utilizando o programa ImageJ. Os exames de Tomografia Computadorizada de Feixe Cônico (TCFC) apresentaram diferenças significativas entre as áreas medidas (p<0,001), enquanto que nas radiografias periapical (p=0,430) e panorâmica (p=0,149) não houve diferença significativa entre os valores médios de densidade nas mesmas áreas. Na comparação entre as áreas dos três exames, observou-se valores maiores naquelas próximas aos implantes em todos os exames: TCFC (127,88 e 120,71), panorâmica (106,51 e 106,09) e periapical (120,32). As áreas mais distantes e próximas aos implantes vizinhos mostraram valores significativamente diferentes nos dois cortes da TCFC quando comparados aos exames periapical e panorâmico. Sendo assim, foi possível confirmar a interferência dos implantes dentários na obtenção dos exames radiográficos e tomográficos, pela alteração dos valores médios de densidade radiográfica na região peri-implantar. Na comparação entre os três exames de imagem investigados, verificou-se que as imagens de TCFC sofreram a maior interferência dos implantes dentários, quando comparadas com as imagens radiográficas.Submitted by Setor de Tratamento da Informação - BC/PUCRS (tede2@pucrs.br) on 2015-05-21T20:19:16Z No. of bitstreams: 1 469176 - Texto Completo.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5)Made available in DSpace on 2015-05-21T20:19:16Z (GMT). No. of bitstreams: 1 469176 - Texto Completo.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5) Previous issue date: 2015-03-30application/pdfhttp://tede2.pucrs.br:80/tede2/retrieve/162675/469176%20-%20Texto%20Completo.pdf.jpgporPontifícia Universidade Católica do Rio Grande do SulPrograma de Pós-Graduação em OdontologiaPUCRSBrasilFaculdade de OdontologiaODONTOLOGIAPRÓTESE DENTÁRIAIMPLANTODONTIATOMOGRAFIA COMPUTADORIZADA DE FEIXE CÔNICODENTES - RADIOGRAFIACIENCIAS DA SAUDE::ODONTOLOGIAA influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônicoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-80965548187336651646006006004673435736271820140-2070498469879244349info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_RSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSTHUMBNAIL469176 - Texto Completo.pdf.jpg469176 - Texto Completo.pdf.jpgimage/jpeg3418http://tede2.pucrs.br/tede2/bitstream/tede/6041/4/469176+-+Texto+Completo.pdf.jpgb6ef697907dc8326ec7a30620cb11de9MD54TEXT469176 - Texto Completo.pdf.txt469176 - Texto Completo.pdf.txttext/plain95321http://tede2.pucrs.br/tede2/bitstream/tede/6041/3/469176+-+Texto+Completo.pdf.txtbc2be684e359e8d1174cd73dff0c3596MD53ORIGINAL469176 - Texto Completo.pdf469176 - Texto Completo.pdfapplication/pdf1075538http://tede2.pucrs.br/tede2/bitstream/tede/6041/2/469176+-+Texto+Completo.pdfc372985d28935427b18fce7ee072399dMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-8610http://tede2.pucrs.br/tede2/bitstream/tede/6041/1/license.txt5a9d6006225b368ef605ba16b4f6d1beMD51tede/60412015-09-29 08:20:05.213oai:tede2.pucrs.br:tede/6041QXV0b3JpemHDp8OjbyBwYXJhIFB1YmxpY2HDp8OjbyBFbGV0csO0bmljYTogQ29tIGJhc2Ugbm8gZGlzcG9zdG8gbmEgTGVpIEZlZGVyYWwgbsK6OS42MTAsIGRlIDE5IGRlIGZldmVyZWlybyBkZSAxOTk4LCBvIGF1dG9yIEFVVE9SSVpBIGEgcHVibGljYcOnw6NvIGVsZXRyw7RuaWNhIGRhIHByZXNlbnRlIG9icmEgbm8gYWNlcnZvIGRhIEJpYmxpb3RlY2EgRGlnaXRhbCBkYSBQb250aWbDrWNpYSBVbml2ZXJzaWRhZGUgQ2F0w7NsaWNhIGRvIFJpbyBHcmFuZGUgZG8gU3VsLCBzZWRpYWRhIGEgQXYuIElwaXJhbmdhIDY2ODEsIFBvcnRvIEFsZWdyZSwgUmlvIEdyYW5kZSBkbyBTdWwsIGNvbSByZWdpc3RybyBkZSBDTlBKIDg4NjMwNDEzMDAwMi04MSBiZW0gY29tbyBlbSBvdXRyYXMgYmlibGlvdGVjYXMgZGlnaXRhaXMsIG5hY2lvbmFpcyBlIGludGVybmFjaW9uYWlzLCBjb25zw7NyY2lvcyBlIHJlZGVzIMOgcyBxdWFpcyBhIGJpYmxpb3RlY2EgZGEgUFVDUlMgcG9zc2EgYSB2aXIgcGFydGljaXBhciwgc2VtIMO0bnVzIGFsdXNpdm8gYW9zIGRpcmVpdG9zIGF1dG9yYWlzLCBhIHTDrXR1bG8gZGUgZGl2dWxnYcOnw6NvIGRhIHByb2R1w6fDo28gY2llbnTDrWZpY2EuCg==Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.pucrs.br/tede2/PRIhttps://tede2.pucrs.br/oai/requestbiblioteca.central@pucrs.br||opendoar:2015-09-29T11:20:05Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.por.fl_str_mv A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
title A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
spellingShingle A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
Felix, Rafael Perdomo
ODONTOLOGIA
PRÓTESE DENTÁRIA
IMPLANTODONTIA
TOMOGRAFIA COMPUTADORIZADA DE FEIXE CÔNICO
DENTES - RADIOGRAFIA
CIENCIAS DA SAUDE::ODONTOLOGIA
title_short A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
title_full A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
title_fullStr A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
title_full_unstemmed A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
title_sort A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico
author Felix, Rafael Perdomo
author_facet Felix, Rafael Perdomo
author_role author
dc.contributor.advisor1.fl_str_mv Rockenbach, Maria Ivete Bolzan
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4779793A9
dc.contributor.advisor-co1.fl_str_mv Shinkai, Rosemary Sadami Arai
dc.contributor.advisor-co1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4765007P0
dc.contributor.authorID.fl_str_mv 008.026.190-61
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4242392H0
dc.contributor.author.fl_str_mv Felix, Rafael Perdomo
contributor_str_mv Rockenbach, Maria Ivete Bolzan
Shinkai, Rosemary Sadami Arai
dc.subject.por.fl_str_mv ODONTOLOGIA
PRÓTESE DENTÁRIA
IMPLANTODONTIA
TOMOGRAFIA COMPUTADORIZADA DE FEIXE CÔNICO
DENTES - RADIOGRAFIA
topic ODONTOLOGIA
PRÓTESE DENTÁRIA
IMPLANTODONTIA
TOMOGRAFIA COMPUTADORIZADA DE FEIXE CÔNICO
DENTES - RADIOGRAFIA
CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ODONTOLOGIA
description Imaging exams performed in areas with the presence of metallic materials such as dental implants can decrease the accuracy of the exams due to metallic artifacts production generated in the peri-implant region. A sample of 21 dental implants placed in 10 patients with Branemark protocol prostheses was evaluated in the periimplant area in image exams of the post-surgery control using periapical radiography (paralleling technique), panoramic radiography and cone-beam computed tomography (CBCT). The radiographic density of different areas bounded near the dental implants were calculated and compared considering their locations and the imaging exams using the software ImageJ. Regarding the different imaging exams, the CBCT showed significant differences between the measured areas (p<0.001), while in periapical (p=0.430) and panoramic (p=0.149) radiographs did not occur significant difference between the gray mean values in these areas. Comparing the areas in the three exams it was observed larger values next to the implants in all exams: CBCT (126.20 and 127.44) panoramic radiography (106.51 and 106.09) and periapical radiography (120.32). The more distant areas and the areas closest to neighboring implants had significant different values in the two reconstructed images of CBCT when compared to the panoramic and periapical radiographs. The interference of dental implants in acquiring radiographic and tomographic exams was confirmed by altered radiographic density mean values in the peri-implant area. Comparing the three exams it was noticed that the CBCT image showed the most significant interference of the dental implants.
publishDate 2015
dc.date.accessioned.fl_str_mv 2015-05-21T20:19:16Z
dc.date.issued.fl_str_mv 2015-03-30
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://tede2.pucrs.br/tede2/handle/tede/6041
url http://tede2.pucrs.br/tede2/handle/tede/6041
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -8096554818733665164
dc.relation.confidence.fl_str_mv 600
600
600
dc.relation.department.fl_str_mv 4673435736271820140
dc.relation.cnpq.fl_str_mv -2070498469879244349
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv PUCRS
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Faculdade de Odontologia
publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Biblioteca Digital de Teses e Dissertações da PUC_RS
collection Biblioteca Digital de Teses e Dissertações da PUC_RS
bitstream.url.fl_str_mv http://tede2.pucrs.br/tede2/bitstream/tede/6041/4/469176+-+Texto+Completo.pdf.jpg
http://tede2.pucrs.br/tede2/bitstream/tede/6041/3/469176+-+Texto+Completo.pdf.txt
http://tede2.pucrs.br/tede2/bitstream/tede/6041/2/469176+-+Texto+Completo.pdf
http://tede2.pucrs.br/tede2/bitstream/tede/6041/1/license.txt
bitstream.checksum.fl_str_mv b6ef697907dc8326ec7a30620cb11de9
bc2be684e359e8d1174cd73dff0c3596
c372985d28935427b18fce7ee072399d
5a9d6006225b368ef605ba16b4f6d1be
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv biblioteca.central@pucrs.br||
_version_ 1799765312797671424