Chair design for radiological examination in disabled
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://doi.org/10.34624/etd.v0i1.1366 |
Resumo: | The general radiography is an important method of diagnosis of the human body image. When this method is applied to disabled people, particularly users of wheelchair, can arise the inconvenience of it (apart from radiographer and patient companions) be exposed to for as long radiation because of the difficulty of his position in relation to X-ray beam. Thus aimed to solve this problem by proposing a chair design, which enables the patient to achievement in sitting examinations position that the principle should be performed in the standing position. To develop the project, the methodological steps were conducted documentary research, problem determination, lifting equipment used in radiology, elaboration of requirements for the new equipment and choice of materials for application in the project, in compliance with the requirements. The result is the design of a chair that uses stainless steel in its structure and carbon fiber components. Will feature support for accommodation of antidifusora grid and chassis X-ray, extensive support for your legs and reclining backrest with tilt angle adjustment locks, thus allowing the performance of tests in different positions. Its use can facilitate the examination, making it more practical and functional, ensuring the independence, satisfaction and physical protection of the patient and also ensuring the physical protection of employees in the industry and patient escorts. |
id |
RCAP_262c1a2f7e3e86d05b285ea3e7b1b056 |
---|---|
oai_identifier_str |
oai:proa.ua.pt:article/1366 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Chair design for radiological examination in disabledProjeto de cadeira para exames radiológicos em deficientes físicosThe general radiography is an important method of diagnosis of the human body image. When this method is applied to disabled people, particularly users of wheelchair, can arise the inconvenience of it (apart from radiographer and patient companions) be exposed to for as long radiation because of the difficulty of his position in relation to X-ray beam. Thus aimed to solve this problem by proposing a chair design, which enables the patient to achievement in sitting examinations position that the principle should be performed in the standing position. To develop the project, the methodological steps were conducted documentary research, problem determination, lifting equipment used in radiology, elaboration of requirements for the new equipment and choice of materials for application in the project, in compliance with the requirements. The result is the design of a chair that uses stainless steel in its structure and carbon fiber components. Will feature support for accommodation of antidifusora grid and chassis X-ray, extensive support for your legs and reclining backrest with tilt angle adjustment locks, thus allowing the performance of tests in different positions. Its use can facilitate the examination, making it more practical and functional, ensuring the independence, satisfaction and physical protection of the patient and also ensuring the physical protection of employees in the industry and patient escorts.A radiografia geral é um importante método de diagnóstico de imagem do corpo humano. Quando este método é aplicado em deficientes físicos, particularmente usuários de cadeira de rodas, pode surgir o inconveniente do mesmo (além do técnico de radiologia e acompanhantes do paciente) ser exposto à radiação por mais tempo que o necessário, devido à dificuldade de seu posicionamento em relação ao feixe de Raios-X. Desta forma, objetivou-se solucionar este problema propondo um projeto de cadeira, que possibilite ao paciente a realização em posição sentada de exames que, a princípio devem ser realizados em posição ortostática. Para desenvolver o projeto, as etapas metodológicas realizadas foram pesquisa documental, determinação do problema, levantamento dos equipamentos utilizados em radiologia, elaboração de requisitos para o novo equipamento e escolha de materiais para aplicação no projeto, em atendimento aos requisitos. O resultado é o projeto de uma cadeira que utiliza o aço inox em sua estrutura e fibra de carbono em seus componentes. Contará com suporte para acomodação da grade antidifusora e o chassi de raios-X, suporte extensivo para as pernas e encosto reclinável com travas de regulagem do ângulo de inclinação, permitindo assim, a realização de exames em diversas posições. Sua utilização poderá facilitar a realização do exame, tornando-o mais prático e funcional, aumentando a autonomia e proteção física do paciente e também garantindo a proteção física dos funcionários do setor e dos acompanhantes do paciente.UA Editora2019-03-25T00:00:00Zjournal articlejournal articlejournal articleinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://doi.org/10.34624/etd.v0i1.1366oai:proa.ua.pt:article/1366Revista dos encontros internacionais Ergotrip Design; No 1 (2016); 124-133Revista dos encontros internacionais Ergotrip Design; Núm. 1 (2016); 124-133Revista dos encontros internacionais Ergotrip Design; n.º 1 (2016); 124-1332183-928Xreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://proa.ua.pt/index.php/ergotripdesign/article/view/1366https://doi.org/10.34624/etd.v0i1.1366https://proa.ua.pt/index.php/ergotripdesign/article/view/1366/1132https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessHenrique Paini, CarlosMaurício Ferreira, Ana CristinaBorges de Araújo, João AlbertoPaschoarelli, Luis Carlos2022-09-22T10:11:25Zoai:proa.ua.pt:article/1366Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:56:45.825561Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Chair design for radiological examination in disabled Projeto de cadeira para exames radiológicos em deficientes físicos |
title |
Chair design for radiological examination in disabled |
spellingShingle |
Chair design for radiological examination in disabled Henrique Paini, Carlos |
title_short |
Chair design for radiological examination in disabled |
title_full |
Chair design for radiological examination in disabled |
title_fullStr |
Chair design for radiological examination in disabled |
title_full_unstemmed |
Chair design for radiological examination in disabled |
title_sort |
Chair design for radiological examination in disabled |
author |
Henrique Paini, Carlos |
author_facet |
Henrique Paini, Carlos Maurício Ferreira, Ana Cristina Borges de Araújo, João Alberto Paschoarelli, Luis Carlos |
author_role |
author |
author2 |
Maurício Ferreira, Ana Cristina Borges de Araújo, João Alberto Paschoarelli, Luis Carlos |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Henrique Paini, Carlos Maurício Ferreira, Ana Cristina Borges de Araújo, João Alberto Paschoarelli, Luis Carlos |
description |
The general radiography is an important method of diagnosis of the human body image. When this method is applied to disabled people, particularly users of wheelchair, can arise the inconvenience of it (apart from radiographer and patient companions) be exposed to for as long radiation because of the difficulty of his position in relation to X-ray beam. Thus aimed to solve this problem by proposing a chair design, which enables the patient to achievement in sitting examinations position that the principle should be performed in the standing position. To develop the project, the methodological steps were conducted documentary research, problem determination, lifting equipment used in radiology, elaboration of requirements for the new equipment and choice of materials for application in the project, in compliance with the requirements. The result is the design of a chair that uses stainless steel in its structure and carbon fiber components. Will feature support for accommodation of antidifusora grid and chassis X-ray, extensive support for your legs and reclining backrest with tilt angle adjustment locks, thus allowing the performance of tests in different positions. Its use can facilitate the examination, making it more practical and functional, ensuring the independence, satisfaction and physical protection of the patient and also ensuring the physical protection of employees in the industry and patient escorts. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-03-25T00:00:00Z |
dc.type.driver.fl_str_mv |
journal article journal article journal article info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://doi.org/10.34624/etd.v0i1.1366 oai:proa.ua.pt:article/1366 |
url |
https://doi.org/10.34624/etd.v0i1.1366 |
identifier_str_mv |
oai:proa.ua.pt:article/1366 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://proa.ua.pt/index.php/ergotripdesign/article/view/1366 https://doi.org/10.34624/etd.v0i1.1366 https://proa.ua.pt/index.php/ergotripdesign/article/view/1366/1132 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
UA Editora |
publisher.none.fl_str_mv |
UA Editora |
dc.source.none.fl_str_mv |
Revista dos encontros internacionais Ergotrip Design; No 1 (2016); 124-133 Revista dos encontros internacionais Ergotrip Design; Núm. 1 (2016); 124-133 Revista dos encontros internacionais Ergotrip Design; n.º 1 (2016); 124-133 2183-928X reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130436522213376 |