Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10198/19604 |
Resumo: | The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p≤0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal·min-1), 45° inclined leg press (Sy.x = 0,54 kcal·min-1), leg extension (Sy.x = 0,59 kcal·min-1), horizontal bench press (Sy.x = 0,47 kcal·min-1), 45° inclined bench press (Sy.x = 0,54 kcal·min-1), lat pull down (Sy.x = 0,28 kcal·min-1), triceps extension (Sy.x = 0,08 kcal·min-1) and biceps curl (Sy.x = 0,13 kcal·min-1). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males. |
id |
RCAP_4d89572ecf8802153395a91a714a08a9 |
---|---|
oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/19604 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?Heart rate measurementsThe aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p≤0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal·min-1), 45° inclined leg press (Sy.x = 0,54 kcal·min-1), leg extension (Sy.x = 0,59 kcal·min-1), horizontal bench press (Sy.x = 0,47 kcal·min-1), 45° inclined bench press (Sy.x = 0,54 kcal·min-1), lat pull down (Sy.x = 0,28 kcal·min-1), triceps extension (Sy.x = 0,08 kcal·min-1) and biceps curl (Sy.x = 0,13 kcal·min-1). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males.This research was supported by Norte Portugal Regional Operational Programme (NORTE 2020), through Portugal 2020 and the European Regional Development Fund, NanoSTIMA, NORTE-01-0145- FEDER-000016 to VMR. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.Dalton Müller Pessôa FilhoBiblioteca Digital do IPBReis, Victor M.Vianna, Jeferson M.Barbosa, Tiago M.Garrido, Nuno D.Alves, José VilaçaCarneiro, André LuizAidar, Felipe J.Novaes, Jefferson2019-09-17T09:13:33Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10198/19604engReis, V.M.; Vianna, Jeferson M.; Barbosa, Tiago M.; Garrido, N.; Alves, José Vilaça; Carneiro, André Luiz; Aidar, Felipe J.; Novaes, Jefferson (2019). Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? PLoS ONE. ISSN 1932-6203. 14:81932-620310.1371/journal.pone.0221284info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-21T10:44:28Zoai:bibliotecadigital.ipb.pt:10198/19604Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T23:10:03.368539Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? |
title |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? |
spellingShingle |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? Reis, Victor M. Heart rate measurements |
title_short |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? |
title_full |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? |
title_fullStr |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? |
title_full_unstemmed |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? |
title_sort |
Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? |
author |
Reis, Victor M. |
author_facet |
Reis, Victor M. Vianna, Jeferson M. Barbosa, Tiago M. Garrido, Nuno D. Alves, José Vilaça Carneiro, André Luiz Aidar, Felipe J. Novaes, Jefferson |
author_role |
author |
author2 |
Vianna, Jeferson M. Barbosa, Tiago M. Garrido, Nuno D. Alves, José Vilaça Carneiro, André Luiz Aidar, Felipe J. Novaes, Jefferson |
author2_role |
author author author author author author author |
dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
dc.contributor.author.fl_str_mv |
Reis, Victor M. Vianna, Jeferson M. Barbosa, Tiago M. Garrido, Nuno D. Alves, José Vilaça Carneiro, André Luiz Aidar, Felipe J. Novaes, Jefferson |
dc.subject.por.fl_str_mv |
Heart rate measurements |
topic |
Heart rate measurements |
description |
The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p≤0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal·min-1), 45° inclined leg press (Sy.x = 0,54 kcal·min-1), leg extension (Sy.x = 0,59 kcal·min-1), horizontal bench press (Sy.x = 0,47 kcal·min-1), 45° inclined bench press (Sy.x = 0,54 kcal·min-1), lat pull down (Sy.x = 0,28 kcal·min-1), triceps extension (Sy.x = 0,08 kcal·min-1) and biceps curl (Sy.x = 0,13 kcal·min-1). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-09-17T09:13:33Z 2019 2019-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/19604 |
url |
http://hdl.handle.net/10198/19604 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Reis, V.M.; Vianna, Jeferson M.; Barbosa, Tiago M.; Garrido, N.; Alves, José Vilaça; Carneiro, André Luiz; Aidar, Felipe J.; Novaes, Jefferson (2019). Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? PLoS ONE. ISSN 1932-6203. 14:8 1932-6203 10.1371/journal.pone.0221284 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Dalton Müller Pessôa Filho |
publisher.none.fl_str_mv |
Dalton Müller Pessôa Filho |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799135365371527168 |