Retinal thickness vs. retinal sensitivity at the central human macula

Detalhes bibliográficos
Autor(a) principal: Bernardes, R.
Data de Publicação: 2008
Outros Autores: Cunha-Vaz, J.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/8390
https://doi.org/10.1111/j.1755-3768.2008.457.x
Resumo: Purpose To assess the detailed correlation between retinal thickness and retinal visual function in the central 300 µm human macular area. Methods Twenty-four eyes with clinically significant macular edema (CSME) (12 eyes with and 12 eyes without central foveal involvement) underwent retinal thickness measurement (RT) and retinal sensitivity, performed by Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA, USA) and MP1 (Microperimetry, Nidek, Japan) systems, respectively. The average retinal thickness in the 300 µm diameter area, centered in the fovea, was computed and correlated with the central MP1 value. RT could also be locally correlated with MP1 values in areas of 30 µm in diameter centered at each stimulus site. Precise correspondence between stimuli and RT locations was ensured by bringing into co-registering the fundus image references from both modalities. Results A moderate correlation was found between RT and central MP1 value (R=-0.578, p=0.003). The correlation decreases when analysing, separately, eyes with or without central foveal involvement (p>0.05 for both groups) being stronger for the CSME eyes with central involvement. Conclusion Cirrus HD-OCT high resolution mapping allows to correlate structure and function at detailed level in the central fovea. It became possible to demonstrate the lack of direct correlation RT/MP1 and the reason why an apparent correlation exist when considering all cases of being part of the same group.
id RCAP_60f244e753010b0d5029cf4f31074b27
oai_identifier_str oai:estudogeral.uc.pt:10316/8390
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Retinal thickness vs. retinal sensitivity at the central human maculaPurpose To assess the detailed correlation between retinal thickness and retinal visual function in the central 300 µm human macular area. Methods Twenty-four eyes with clinically significant macular edema (CSME) (12 eyes with and 12 eyes without central foveal involvement) underwent retinal thickness measurement (RT) and retinal sensitivity, performed by Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA, USA) and MP1 (Microperimetry, Nidek, Japan) systems, respectively. The average retinal thickness in the 300 µm diameter area, centered in the fovea, was computed and correlated with the central MP1 value. RT could also be locally correlated with MP1 values in areas of 30 µm in diameter centered at each stimulus site. Precise correspondence between stimuli and RT locations was ensured by bringing into co-registering the fundus image references from both modalities. Results A moderate correlation was found between RT and central MP1 value (R=-0.578, p=0.003). The correlation decreases when analysing, separately, eyes with or without central foveal involvement (p>0.05 for both groups) being stronger for the CSME eyes with central involvement. Conclusion Cirrus HD-OCT high resolution mapping allows to correlate structure and function at detailed level in the central fovea. It became possible to demonstrate the lack of direct correlation RT/MP1 and the reason why an apparent correlation exist when considering all cases of being part of the same group.2008info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/8390http://hdl.handle.net/10316/8390https://doi.org/10.1111/j.1755-3768.2008.457.xengActa Ophthalmologica. 86:s243 (2008) 0-0Bernardes, R.Cunha-Vaz, J.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-05-27T16:14:35Zoai:estudogeral.uc.pt:10316/8390Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:43:35.558759Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Retinal thickness vs. retinal sensitivity at the central human macula
title Retinal thickness vs. retinal sensitivity at the central human macula
spellingShingle Retinal thickness vs. retinal sensitivity at the central human macula
Bernardes, R.
title_short Retinal thickness vs. retinal sensitivity at the central human macula
title_full Retinal thickness vs. retinal sensitivity at the central human macula
title_fullStr Retinal thickness vs. retinal sensitivity at the central human macula
title_full_unstemmed Retinal thickness vs. retinal sensitivity at the central human macula
title_sort Retinal thickness vs. retinal sensitivity at the central human macula
author Bernardes, R.
author_facet Bernardes, R.
Cunha-Vaz, J.
author_role author
author2 Cunha-Vaz, J.
author2_role author
dc.contributor.author.fl_str_mv Bernardes, R.
Cunha-Vaz, J.
description Purpose To assess the detailed correlation between retinal thickness and retinal visual function in the central 300 µm human macular area. Methods Twenty-four eyes with clinically significant macular edema (CSME) (12 eyes with and 12 eyes without central foveal involvement) underwent retinal thickness measurement (RT) and retinal sensitivity, performed by Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA, USA) and MP1 (Microperimetry, Nidek, Japan) systems, respectively. The average retinal thickness in the 300 µm diameter area, centered in the fovea, was computed and correlated with the central MP1 value. RT could also be locally correlated with MP1 values in areas of 30 µm in diameter centered at each stimulus site. Precise correspondence between stimuli and RT locations was ensured by bringing into co-registering the fundus image references from both modalities. Results A moderate correlation was found between RT and central MP1 value (R=-0.578, p=0.003). The correlation decreases when analysing, separately, eyes with or without central foveal involvement (p>0.05 for both groups) being stronger for the CSME eyes with central involvement. Conclusion Cirrus HD-OCT high resolution mapping allows to correlate structure and function at detailed level in the central fovea. It became possible to demonstrate the lack of direct correlation RT/MP1 and the reason why an apparent correlation exist when considering all cases of being part of the same group.
publishDate 2008
dc.date.none.fl_str_mv 2008
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/8390
http://hdl.handle.net/10316/8390
https://doi.org/10.1111/j.1755-3768.2008.457.x
url http://hdl.handle.net/10316/8390
https://doi.org/10.1111/j.1755-3768.2008.457.x
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Ophthalmologica. 86:s243 (2008) 0-0
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133707859132416