Resumo: | INTRODUCTION: The management of periprosthetic femoral fractures following hip arthroplasty is challenging, and the choice between osteosynthesis of the fracture and the revision of the prosthesis is still matter of discussion. CASE REPORT: In a 81-year-old male patient, a bilateral Vancouver type-B2 periprosthetic femoral fracture with stem loosening occurred after an accidental fall. The patient had severe medical comorbidities. The radiographic study showed a bilateral Robert Mathys cementless total hip arthroplasty at 24 and 21-years follow-up. The fractures were treated with open reduction and fixation with locking compression plates. Bicortical fixation of the loose stem was obtained by the screws of the locking plate, due to the polymeric composition of the isoelastic femoral stem. Both fractures sites were augmented with bone allografts. At follow-up period of 12 months, the X-rays showed bone union of both fractures and bilateral stable stem fixation. The patient expressed high degree of satisfaction with surgery result. DISCUSSION: The standard treatment for Vancouver type-B2 periprosthetic femoral fractures is the removal of the loose implant, fixation of the fracture, and implantation of a new revision femoral stem. However, the implantation of two long revision hip prostheses is a major operation for an older patient with precarious health condition, which can contribute to higher risk of medical and prosthetic complications. CONCLUSION: In older patients with multiple comorbidities, the use of locking plates can be a valid treatment of bilateral Vancouver B2-periprosthetic femoral fractures following RM® cementless isoelastic stem, as an alternative surgical option to femoral stem revision. |
id |
RCAP_836eb4b7b274ac9135c688c41f5bd1cc |
---|---|
oai_identifier_str |
oai:rihuc.huc.min-saude.pt:10400.4/2228 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case reportArtroplastia Total da AncaFixação Interna de FracturasRessonância MagnéticaINTRODUCTION: The management of periprosthetic femoral fractures following hip arthroplasty is challenging, and the choice between osteosynthesis of the fracture and the revision of the prosthesis is still matter of discussion. CASE REPORT: In a 81-year-old male patient, a bilateral Vancouver type-B2 periprosthetic femoral fracture with stem loosening occurred after an accidental fall. The patient had severe medical comorbidities. The radiographic study showed a bilateral Robert Mathys cementless total hip arthroplasty at 24 and 21-years follow-up. The fractures were treated with open reduction and fixation with locking compression plates. Bicortical fixation of the loose stem was obtained by the screws of the locking plate, due to the polymeric composition of the isoelastic femoral stem. Both fractures sites were augmented with bone allografts. At follow-up period of 12 months, the X-rays showed bone union of both fractures and bilateral stable stem fixation. The patient expressed high degree of satisfaction with surgery result. DISCUSSION: The standard treatment for Vancouver type-B2 periprosthetic femoral fractures is the removal of the loose implant, fixation of the fracture, and implantation of a new revision femoral stem. However, the implantation of two long revision hip prostheses is a major operation for an older patient with precarious health condition, which can contribute to higher risk of medical and prosthetic complications. CONCLUSION: In older patients with multiple comorbidities, the use of locking plates can be a valid treatment of bilateral Vancouver B2-periprosthetic femoral fractures following RM® cementless isoelastic stem, as an alternative surgical option to femoral stem revision.RIHUCFerreira, IDCura Mariano, JLucas, FMJudas, F2019-06-21T15:32:13Z2019-05-112019-05-11T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.4/2228engInt J Surg Case Rep. 2019 May 11;60:98-102.10.1016/j.ijscr.2019.05.009info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-11T14:23:36Zoai:rihuc.huc.min-saude.pt:10400.4/2228Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:04:41.526321Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report |
title |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report |
spellingShingle |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report Ferreira, ID Artroplastia Total da Anca Fixação Interna de Fracturas Ressonância Magnética |
title_short |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report |
title_full |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report |
title_fullStr |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report |
title_full_unstemmed |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report |
title_sort |
Osteosynthesis of bilateral Vancouver B2 periprosthetic femoral fracture after a bilateral RM® total hip arthroplasty at 24 and 21-years follow-up: A case report |
author |
Ferreira, ID |
author_facet |
Ferreira, ID Cura Mariano, J Lucas, FM Judas, F |
author_role |
author |
author2 |
Cura Mariano, J Lucas, FM Judas, F |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
RIHUC |
dc.contributor.author.fl_str_mv |
Ferreira, ID Cura Mariano, J Lucas, FM Judas, F |
dc.subject.por.fl_str_mv |
Artroplastia Total da Anca Fixação Interna de Fracturas Ressonância Magnética |
topic |
Artroplastia Total da Anca Fixação Interna de Fracturas Ressonância Magnética |
description |
INTRODUCTION: The management of periprosthetic femoral fractures following hip arthroplasty is challenging, and the choice between osteosynthesis of the fracture and the revision of the prosthesis is still matter of discussion. CASE REPORT: In a 81-year-old male patient, a bilateral Vancouver type-B2 periprosthetic femoral fracture with stem loosening occurred after an accidental fall. The patient had severe medical comorbidities. The radiographic study showed a bilateral Robert Mathys cementless total hip arthroplasty at 24 and 21-years follow-up. The fractures were treated with open reduction and fixation with locking compression plates. Bicortical fixation of the loose stem was obtained by the screws of the locking plate, due to the polymeric composition of the isoelastic femoral stem. Both fractures sites were augmented with bone allografts. At follow-up period of 12 months, the X-rays showed bone union of both fractures and bilateral stable stem fixation. The patient expressed high degree of satisfaction with surgery result. DISCUSSION: The standard treatment for Vancouver type-B2 periprosthetic femoral fractures is the removal of the loose implant, fixation of the fracture, and implantation of a new revision femoral stem. However, the implantation of two long revision hip prostheses is a major operation for an older patient with precarious health condition, which can contribute to higher risk of medical and prosthetic complications. CONCLUSION: In older patients with multiple comorbidities, the use of locking plates can be a valid treatment of bilateral Vancouver B2-periprosthetic femoral fractures following RM® cementless isoelastic stem, as an alternative surgical option to femoral stem revision. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-06-21T15:32:13Z 2019-05-11 2019-05-11T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.4/2228 |
url |
http://hdl.handle.net/10400.4/2228 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Int J Surg Case Rep. 2019 May 11;60:98-102. 10.1016/j.ijscr.2019.05.009 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131708894740481 |