Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal

Detalhes bibliográficos
Autor(a) principal: Rebelo, Ana Cristina da Costa
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/38833
Resumo: Dissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.
id RCAP_8787e5cba84f99db81a5083b0a2020ea
oai_identifier_str oai:estudogeral.uc.pt:10316/38833
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em PortugalOptimum point of economic profitability of glazing applied on buildings located in PortugalJanelasVãos envidraçadosEficiência EnergéticaCusto anual equivalenteEdifíciosWindowsGlazed SystemsEnergy EfficiencyEquivalent Annual CostBuildingsDissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.A eficiência energética dos edifícios depende do comportamento dos seus utilizadores e do desempenho energético de cada uma das componentes que os caraterizam, nomeadamente da envolvente. Por sua vez, a eficiência energética desta depende muito dos seus elementos potencialmente mais problemáticos, os vãos envidraçados. Isto levou a que o principal componente dos envidraçados, as janelas, sejam cada vez mais eficazes em termos de performance térmica, mas também cada vez com maior custo de aquisição. É, então, legítimo questionar se o retorno conseguido em termos de poupança energética compensa o esforço económico adicional requerido para instalar janelas energeticamente mais eficazes. Com este trabalho pretendeu-se caraterizar as janelas habitualmente instaladas no edificado português, quer em termos de qualidade energética quer de custo de aquisição, e avaliar a relação que existe entre estes dois parâmetros. Pretendeu-se ainda relacionar o custo de aquisição das janelas com a redução de gastos em energia que promovem, e assim identificar o seu ponto ótimo de rentabilidade económica. Foi contatado um conjunto muito alargado de fabricantes de janelas, aos quais foi pedido orçamento para janelas com o tamanho mais frequentemente instalado e para qualidades energéticas desde muita má a excelente, dos quais 18 responderam. Procedeu-se depois a uma determinação das caraterísticas energéticas das mesmas recorrendo aos softwares “Calumen II” e “Guardian Configurator”. Obteve-se assim uma caraterização das janelas em termos de preço de aquisição e de qualidade energética. Para identificar o ponto ótimo de rentabilidade económica das janelas recorreu-se ao conceito de Custo Anual Equivalente (CAE) do edifício. Para o efeito utilizou-se o software SEnergEd, que faz a simulação do comportamento energético e do CAE de edifícios através de uma metodologia de cálculo baseada no modelo dinâmico horário monozona descrito na norma ISO 13790 (2006). Foi identificada a classe energética das janelas com menor CAE para 4 tipologias de edifício e para as 3 condições climáticas características de Portugal. Dos resultados obtidos foi possível concluir que não existe qualquer relação da janela ótima com o fator de forma do edifício ou com o fator de área de envidraçados. O que determina a janela ótima a instalar é a tipologia de utilização do edifício.The energy efficiency of buildings depends on the behaviour of its users and the energy performance of each one of the aspects which characterize them, namely the surrounding environment. On the other hand, the energy efficiency of this depends much on the solution used on the construction of their potentially more problematic elements, particularly glazing systems. This led to the fact that the main component of glazing, the windows, are gradually more effective, but have also an increasingly higher acquisition cost. It is, therefore, legitimate to question whether the return achieved in terms of energy saving offsets the additional economic effort required to install more energy efficient windows. This work intends to characterize the windows usually installed in the Portuguese buildings, either in terms of energy quality or acquisition costs, and to evaluate the relationship between these two parameters. Its aim is also to relate the windows acquisition cost with the reduction of the energy costs they promote, and thus identify its optimal cost-effectiveness. A very wide range of window manufacturers was contacted and asked to quote windows with the most commonly installed size and for energy qualities graded from very bad to excellent, to which 18 responded. Afterwards, their energy characteristics were determined using for this end the Calumen II and Guardian Configurator software. Hence, it was achieved a characterization of the windows in terms of acquisition cost and energy quality. To identify the optimal cost-effectiveness of the windows, the concept of Equivalent Annual Cost (EAC) of the building was considered. For this purpose it was used the SEnergEd software which makes the simulation of the energy performance and the EAC of the buildings through a calculation method based on the hourly mono zone dynamic model described in ISO 13790 (2006). The energy class of windows with lower EAC for 4 building typologies and for 3 typical climate conditions of Portugal was identified. From the results obtained, it was concluded that there is no relationship between the optimal window and the building form factor or the glazed area factor. What determines the optimal window to be installed is the use of building typology.2016-02-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/38833http://hdl.handle.net/10316/38833TID:201664518porRebelo, Ana Cristina da Costainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-01-12T10:03:30Zoai:estudogeral.uc.pt:10316/38833Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:04.812919Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
Optimum point of economic profitability of glazing applied on buildings located in Portugal
title Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
spellingShingle Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
Rebelo, Ana Cristina da Costa
Janelas
Vãos envidraçados
Eficiência Energética
Custo anual equivalente
Edifícios
Windows
Glazed Systems
Energy Efficiency
Equivalent Annual Cost
Buildings
title_short Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
title_full Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
title_fullStr Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
title_full_unstemmed Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
title_sort Ponto ótimo de rentabilidade económica dos envidraçados aplicados em edifícios localizados em Portugal
author Rebelo, Ana Cristina da Costa
author_facet Rebelo, Ana Cristina da Costa
author_role author
dc.contributor.author.fl_str_mv Rebelo, Ana Cristina da Costa
dc.subject.por.fl_str_mv Janelas
Vãos envidraçados
Eficiência Energética
Custo anual equivalente
Edifícios
Windows
Glazed Systems
Energy Efficiency
Equivalent Annual Cost
Buildings
topic Janelas
Vãos envidraçados
Eficiência Energética
Custo anual equivalente
Edifícios
Windows
Glazed Systems
Energy Efficiency
Equivalent Annual Cost
Buildings
description Dissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.
publishDate 2016
dc.date.none.fl_str_mv 2016-02-25
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/38833
http://hdl.handle.net/10316/38833
TID:201664518
url http://hdl.handle.net/10316/38833
identifier_str_mv TID:201664518
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133882225786880