Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images

Detalhes bibliográficos
Autor(a) principal: Queirós, Sandro
Data de Publicação: 2018
Outros Autores: Morais, Pedro, Dubois, Christophe, Voigt, Jens-Uwe, Fehske, Wolfgang, Kuhn, Andreas, Achenbach, Tobias, Fonseca, Jaime, Vilaça, João, D'hooge, Jan
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/11110/1414
Resumo: Background: Accurate aortic annulus (AoA) sizing is crucial for transcatheter aortic valve implantation planning. Three-dimensional (3D) transesophageal echocardiography (TEE) is a viable alternative to the standard multidetector row computed tomography (MDCT) for such assessment, with few automatic software solutions available. The aim of this study was to present and evaluate a novel software tool for automatic AoA sizing by3D TEE. Methods: One hundred one patients who underwent both preoperative MDCT and 3D TEE were retrospectively analyzed using the software. The automatic software measurements’ accuracy was compared against values obtained using standard manual MDCT, as well as against those obtained using manual 3D TEE, and intraobserver, interobserver, and test-retest reproducibility was assessed. Because the software can be used as a fully automatic or as an interactive tool, both options were addressed and contrasted. The impact of these measures on the recommended prosthesis size was then evaluated to assess if the software’s automated sizes were concordant with those obtained using an MDCT- or a TEE-based manual sizing strategy. Results: The software showed very good agreement with manual values obtained using MDCT and 3D TEE, with the interactive approach having slightly narrower limits of agreement. The latter also had excellent intra-and interobserver variability. Both fully automatic and interactive analyses showed excellent test-retest reproducibility, with the first having a faster analysis time. Finally, either approach led to good sizing agreement against the true implanted sizes (>77%) and against MDCT-based sizes (>88%). Conclusions: Given the automated, reproducible, and fast nature of its analyses, the novel software tool presented here may potentially facilitate and thus increase the use of 3D TEE for preoperative transcatheter aortic valve implantation sizing.
id RCAP_a7f8c368dd9da6f5effad86ce48e9a22
oai_identifier_str oai:ciencipca.ipca.pt:11110/1414
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic ImagesAortic valve sizing3D transesophageal echocardiographyFully automatic analysisInteractive analysisTranscatheter aortic valve implantationBackground: Accurate aortic annulus (AoA) sizing is crucial for transcatheter aortic valve implantation planning. Three-dimensional (3D) transesophageal echocardiography (TEE) is a viable alternative to the standard multidetector row computed tomography (MDCT) for such assessment, with few automatic software solutions available. The aim of this study was to present and evaluate a novel software tool for automatic AoA sizing by3D TEE. Methods: One hundred one patients who underwent both preoperative MDCT and 3D TEE were retrospectively analyzed using the software. The automatic software measurements’ accuracy was compared against values obtained using standard manual MDCT, as well as against those obtained using manual 3D TEE, and intraobserver, interobserver, and test-retest reproducibility was assessed. Because the software can be used as a fully automatic or as an interactive tool, both options were addressed and contrasted. The impact of these measures on the recommended prosthesis size was then evaluated to assess if the software’s automated sizes were concordant with those obtained using an MDCT- or a TEE-based manual sizing strategy. Results: The software showed very good agreement with manual values obtained using MDCT and 3D TEE, with the interactive approach having slightly narrower limits of agreement. The latter also had excellent intra-and interobserver variability. Both fully automatic and interactive analyses showed excellent test-retest reproducibility, with the first having a faster analysis time. Finally, either approach led to good sizing agreement against the true implanted sizes (>77%) and against MDCT-based sizes (>88%). Conclusions: Given the automated, reproducible, and fast nature of its analyses, the novel software tool presented here may potentially facilitate and thus increase the use of 3D TEE for preoperative transcatheter aortic valve implantation sizing.This work was funded by projects ‘‘NORTE-01-0145-FEDER-000013’’ and‘‘NORTE-01-0145-FEDER-024300,’’ supported by Northern Portugal RegionalOperational Programme (Norte2020), under the Portugal 2020 Partnership Agreement, through the European Regional Development Fund. This work has also been funded by European Regional Development Fund funds, through the Competitive-ness Factors Operational Programme, and by national funds, through Fundação para a Ciência e Tecnologia, under the scope of the project POCI-01-0145-FEDER-007038. The authors also acknowledge support from Fundação para aCi^encia e Tecnologia and the European Social Found, through Programa Operational Capital Humano, in the scope of PhD grants SFRH/BD/93443/2013 (S.Q.)and SFRH/BD/95438/2013 (P.M.).Journal of the American Society of Echocardiography2018-09-12T13:46:55Z2018-05-03T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/11110/1414oai:ciencipca.ipca.pt:11110/1414eng0894-7317http://hdl.handle.net/11110/1414metadata only accessinfo:eu-repo/semantics/openAccessQueirós, SandroMorais, PedroDubois, ChristopheVoigt, Jens-UweFehske, WolfgangKuhn, AndreasAchenbach, TobiasFonseca, JaimeVilaça, JoãoD'hooge, Janreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-05T12:52:51Zoai:ciencipca.ipca.pt:11110/1414Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:01:47.264190Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
title Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
spellingShingle Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
Queirós, Sandro
Aortic valve sizing
3D transesophageal echocardiography
Fully automatic analysis
Interactive analysis
Transcatheter aortic valve implantation
title_short Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
title_full Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
title_fullStr Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
title_full_unstemmed Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
title_sort Validation of a Novel Software Tool for Automatic Aortic Annular Sizing in Three-Dimensional Transesophageal Echocardiographic Images
author Queirós, Sandro
author_facet Queirós, Sandro
Morais, Pedro
Dubois, Christophe
Voigt, Jens-Uwe
Fehske, Wolfgang
Kuhn, Andreas
Achenbach, Tobias
Fonseca, Jaime
Vilaça, João
D'hooge, Jan
author_role author
author2 Morais, Pedro
Dubois, Christophe
Voigt, Jens-Uwe
Fehske, Wolfgang
Kuhn, Andreas
Achenbach, Tobias
Fonseca, Jaime
Vilaça, João
D'hooge, Jan
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Queirós, Sandro
Morais, Pedro
Dubois, Christophe
Voigt, Jens-Uwe
Fehske, Wolfgang
Kuhn, Andreas
Achenbach, Tobias
Fonseca, Jaime
Vilaça, João
D'hooge, Jan
dc.subject.por.fl_str_mv Aortic valve sizing
3D transesophageal echocardiography
Fully automatic analysis
Interactive analysis
Transcatheter aortic valve implantation
topic Aortic valve sizing
3D transesophageal echocardiography
Fully automatic analysis
Interactive analysis
Transcatheter aortic valve implantation
description Background: Accurate aortic annulus (AoA) sizing is crucial for transcatheter aortic valve implantation planning. Three-dimensional (3D) transesophageal echocardiography (TEE) is a viable alternative to the standard multidetector row computed tomography (MDCT) for such assessment, with few automatic software solutions available. The aim of this study was to present and evaluate a novel software tool for automatic AoA sizing by3D TEE. Methods: One hundred one patients who underwent both preoperative MDCT and 3D TEE were retrospectively analyzed using the software. The automatic software measurements’ accuracy was compared against values obtained using standard manual MDCT, as well as against those obtained using manual 3D TEE, and intraobserver, interobserver, and test-retest reproducibility was assessed. Because the software can be used as a fully automatic or as an interactive tool, both options were addressed and contrasted. The impact of these measures on the recommended prosthesis size was then evaluated to assess if the software’s automated sizes were concordant with those obtained using an MDCT- or a TEE-based manual sizing strategy. Results: The software showed very good agreement with manual values obtained using MDCT and 3D TEE, with the interactive approach having slightly narrower limits of agreement. The latter also had excellent intra-and interobserver variability. Both fully automatic and interactive analyses showed excellent test-retest reproducibility, with the first having a faster analysis time. Finally, either approach led to good sizing agreement against the true implanted sizes (>77%) and against MDCT-based sizes (>88%). Conclusions: Given the automated, reproducible, and fast nature of its analyses, the novel software tool presented here may potentially facilitate and thus increase the use of 3D TEE for preoperative transcatheter aortic valve implantation sizing.
publishDate 2018
dc.date.none.fl_str_mv 2018-09-12T13:46:55Z
2018-05-03T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/11110/1414
oai:ciencipca.ipca.pt:11110/1414
url http://hdl.handle.net/11110/1414
identifier_str_mv oai:ciencipca.ipca.pt:11110/1414
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0894-7317
http://hdl.handle.net/11110/1414
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Journal of the American Society of Echocardiography
publisher.none.fl_str_mv Journal of the American Society of Echocardiography
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799129887466848256