EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista brasileira de medicina do esporte (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922021000900722 |
Resumo: | ABSTRACT Introduction: An isokinetic test refers to the test of the force of a muscle or muscle group during centripetal and centrifugal movements at a constant speed in the whole range of joint motion by means of a isokinetic force tester. Objective: To explore the application of the knee centripetal flexor and extensor muscle groups in the blood oxygen saturation of high jumpers. Methods: Eighteen teenage female high jumper athletes above level 2 in a city sports school were selected. Their ages was 16.89±1.02 years old; height, 168.31±6.32cm; weight, 55.36±6.75kg. Results: At 60° S and 120° S test speed, the peak moment of the extensor muscle group on the same side of the knee was significantly greater than that of the flexor muscle group (P<0.05), while at 240° S test speed, it was the opposite. There was a significant difference in the peak moment of the flexor muscle group on the left and right side of the knee (P<0.01). Conclusions: The function of the dynamic muscle strength test system is one of the methods of studying the human muscle function. and can be used to test and evaluate the general strength of athletes. Level of evidence II; Therapeutic studies - investigation of treatment results. |
id |
SBMEE-1_64a361803b30bf47d4831ec005e0a514 |
---|---|
oai_identifier_str |
oai:scielo:S1517-86922021000900722 |
network_acronym_str |
SBMEE-1 |
network_name_str |
Revista brasileira de medicina do esporte (Online) |
repository_id_str |
|
spelling |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TESTAthletesMuscle strengthExercise testABSTRACT Introduction: An isokinetic test refers to the test of the force of a muscle or muscle group during centripetal and centrifugal movements at a constant speed in the whole range of joint motion by means of a isokinetic force tester. Objective: To explore the application of the knee centripetal flexor and extensor muscle groups in the blood oxygen saturation of high jumpers. Methods: Eighteen teenage female high jumper athletes above level 2 in a city sports school were selected. Their ages was 16.89±1.02 years old; height, 168.31±6.32cm; weight, 55.36±6.75kg. Results: At 60° S and 120° S test speed, the peak moment of the extensor muscle group on the same side of the knee was significantly greater than that of the flexor muscle group (P<0.05), while at 240° S test speed, it was the opposite. There was a significant difference in the peak moment of the flexor muscle group on the left and right side of the knee (P<0.01). Conclusions: The function of the dynamic muscle strength test system is one of the methods of studying the human muscle function. and can be used to test and evaluate the general strength of athletes. Level of evidence II; Therapeutic studies - investigation of treatment results.Sociedade Brasileira de Medicina do Exercício e do Esporte2021-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922021000900722Revista Brasileira de Medicina do Esporte v.27 n.7 2021reponame:Revista brasileira de medicina do esporte (Online)instname:Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE)instacron:SBMEE10.1590/1517-8692202127072021_0341info:eu-repo/semantics/openAccessYao,Qiangeng2021-12-01T00:00:00Zoai:scielo:S1517-86922021000900722Revistahttp://www.scielo.br/rbmeONGhttps://old.scielo.br/oai/scielo-oai.php||revista@medicinadoesporte.org.br1806-99401517-8692opendoar:2021-12-01T00:00Revista brasileira de medicina do esporte (Online) - Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE)false |
dc.title.none.fl_str_mv |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST |
title |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST |
spellingShingle |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST Yao,Qiang Athletes Muscle strength Exercise test |
title_short |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST |
title_full |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST |
title_fullStr |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST |
title_full_unstemmed |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST |
title_sort |
EVALUATION OF BLOOD OXYGEN SATURATION OF HIGH JUMPERS BASED ON ISOKINETIC TEST |
author |
Yao,Qiang |
author_facet |
Yao,Qiang |
author_role |
author |
dc.contributor.author.fl_str_mv |
Yao,Qiang |
dc.subject.por.fl_str_mv |
Athletes Muscle strength Exercise test |
topic |
Athletes Muscle strength Exercise test |
description |
ABSTRACT Introduction: An isokinetic test refers to the test of the force of a muscle or muscle group during centripetal and centrifugal movements at a constant speed in the whole range of joint motion by means of a isokinetic force tester. Objective: To explore the application of the knee centripetal flexor and extensor muscle groups in the blood oxygen saturation of high jumpers. Methods: Eighteen teenage female high jumper athletes above level 2 in a city sports school were selected. Their ages was 16.89±1.02 years old; height, 168.31±6.32cm; weight, 55.36±6.75kg. Results: At 60° S and 120° S test speed, the peak moment of the extensor muscle group on the same side of the knee was significantly greater than that of the flexor muscle group (P<0.05), while at 240° S test speed, it was the opposite. There was a significant difference in the peak moment of the flexor muscle group on the left and right side of the knee (P<0.01). Conclusions: The function of the dynamic muscle strength test system is one of the methods of studying the human muscle function. and can be used to test and evaluate the general strength of athletes. Level of evidence II; Therapeutic studies - investigation of treatment results. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-07-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922021000900722 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-86922021000900722 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1517-8692202127072021_0341 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Medicina do Exercício e do Esporte |
publisher.none.fl_str_mv |
Sociedade Brasileira de Medicina do Exercício e do Esporte |
dc.source.none.fl_str_mv |
Revista Brasileira de Medicina do Esporte v.27 n.7 2021 reponame:Revista brasileira de medicina do esporte (Online) instname:Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE) instacron:SBMEE |
instname_str |
Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE) |
instacron_str |
SBMEE |
institution |
SBMEE |
reponame_str |
Revista brasileira de medicina do esporte (Online) |
collection |
Revista brasileira de medicina do esporte (Online) |
repository.name.fl_str_mv |
Revista brasileira de medicina do esporte (Online) - Sociedade Brasileira de Medicina do Exercício e do Esporte (SBMEE) |
repository.mail.fl_str_mv |
||revista@medicinadoesporte.org.br |
_version_ |
1752122238121803776 |