Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Ortopédica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400184 |
Resumo: | OBJECTIVE: To investigate the reliability of the 50-Foot Walk Test (50 FWT) and 30-second Chair Stand Test (30 CST) in patients who have undergone total knee arthroplasty (TKA). METHODS: The study was designed as a test-retest research. Thirty-three patients who would undergo bilateral TKA were recruited. The tests 30 CST and 50 FWT were performed twice on the same day with 5-minute intervals, respectively. Between the first and second tests, patients waited for an hour on sitting position in order to prevent fatigue. In addition to these tests, we registered the knee pain experienced by the patients using a 100 mm VAS scale. RESULTS: The 50 FWT and 30 CST showed excellent reliability. ICC for 50 FWT and 30 CST were 0.97 and 0.92, respectively. SRD95 was 1.07 for 50 FWT and 0.96 for 30 CST. CONCLUSIONS: According to results of this study, both 50 FWT and 30 CST have excellent reliability in patients with TKA. These tests are simple, no time consuming and constitute sensitive methods to measure the functional performance in patients with TKA in the clinical settings. Clinicians and researchers may use these tests to quantify even small changes in functional performance for patients with TKA. Level of Evidence III, Diagnostic Study. |
id |
SBOT-1_35d9866502de2e10b71505c5849723a0 |
---|---|
oai_identifier_str |
oai:scielo:S1413-78522015000400184 |
network_acronym_str |
SBOT-1 |
network_name_str |
Acta Ortopédica Brasileira (Online) |
repository_id_str |
|
spelling |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplastyArthroplastyReplacementKneePerformance testsRehabilitation OBJECTIVE: To investigate the reliability of the 50-Foot Walk Test (50 FWT) and 30-second Chair Stand Test (30 CST) in patients who have undergone total knee arthroplasty (TKA). METHODS: The study was designed as a test-retest research. Thirty-three patients who would undergo bilateral TKA were recruited. The tests 30 CST and 50 FWT were performed twice on the same day with 5-minute intervals, respectively. Between the first and second tests, patients waited for an hour on sitting position in order to prevent fatigue. In addition to these tests, we registered the knee pain experienced by the patients using a 100 mm VAS scale. RESULTS: The 50 FWT and 30 CST showed excellent reliability. ICC for 50 FWT and 30 CST were 0.97 and 0.92, respectively. SRD95 was 1.07 for 50 FWT and 0.96 for 30 CST. CONCLUSIONS: According to results of this study, both 50 FWT and 30 CST have excellent reliability in patients with TKA. These tests are simple, no time consuming and constitute sensitive methods to measure the functional performance in patients with TKA in the clinical settings. Clinicians and researchers may use these tests to quantify even small changes in functional performance for patients with TKA. Level of Evidence III, Diagnostic Study. ATHA EDITORA2015-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400184Acta Ortopédica Brasileira v.23 n.4 2015reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-78522015230401018info:eu-repo/semantics/openAccessUnver,BayramKalkan,SerpilYuksel,ErtugrulKahraman,TurhanKaratosun,Vasfieng2015-08-04T00:00:00Zoai:scielo:S1413-78522015000400184Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2015-08-04T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty |
title |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty |
spellingShingle |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty Unver,Bayram Arthroplasty Replacement Knee Performance tests Rehabilitation |
title_short |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty |
title_full |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty |
title_fullStr |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty |
title_full_unstemmed |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty |
title_sort |
Reliability of the 50-foot walk test and 30-sec chair stand test in total knee arthroplasty |
author |
Unver,Bayram |
author_facet |
Unver,Bayram Kalkan,Serpil Yuksel,Ertugrul Kahraman,Turhan Karatosun,Vasfi |
author_role |
author |
author2 |
Kalkan,Serpil Yuksel,Ertugrul Kahraman,Turhan Karatosun,Vasfi |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Unver,Bayram Kalkan,Serpil Yuksel,Ertugrul Kahraman,Turhan Karatosun,Vasfi |
dc.subject.por.fl_str_mv |
Arthroplasty Replacement Knee Performance tests Rehabilitation |
topic |
Arthroplasty Replacement Knee Performance tests Rehabilitation |
description |
OBJECTIVE: To investigate the reliability of the 50-Foot Walk Test (50 FWT) and 30-second Chair Stand Test (30 CST) in patients who have undergone total knee arthroplasty (TKA). METHODS: The study was designed as a test-retest research. Thirty-three patients who would undergo bilateral TKA were recruited. The tests 30 CST and 50 FWT were performed twice on the same day with 5-minute intervals, respectively. Between the first and second tests, patients waited for an hour on sitting position in order to prevent fatigue. In addition to these tests, we registered the knee pain experienced by the patients using a 100 mm VAS scale. RESULTS: The 50 FWT and 30 CST showed excellent reliability. ICC for 50 FWT and 30 CST were 0.97 and 0.92, respectively. SRD95 was 1.07 for 50 FWT and 0.96 for 30 CST. CONCLUSIONS: According to results of this study, both 50 FWT and 30 CST have excellent reliability in patients with TKA. These tests are simple, no time consuming and constitute sensitive methods to measure the functional performance in patients with TKA in the clinical settings. Clinicians and researchers may use these tests to quantify even small changes in functional performance for patients with TKA. Level of Evidence III, Diagnostic Study. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400184 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522015000400184 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1413-78522015230401018 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ATHA EDITORA |
publisher.none.fl_str_mv |
ATHA EDITORA |
dc.source.none.fl_str_mv |
Acta Ortopédica Brasileira v.23 n.4 2015 reponame:Acta Ortopédica Brasileira (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Acta Ortopédica Brasileira (Online) |
collection |
Acta Ortopédica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
1atha@uol.com.br||actaortopedicabrasileira@uol.com.br |
_version_ |
1752122275158556672 |