Hamstring tendons insertion - an anatomical study

Detalhes bibliográficos
Autor(a) principal: Grassi,Cristiano Antonio
Data de Publicação: 2013
Outros Autores: Fruheling,Vagner Messias, Abdo,Joao Caetano, Moura,Marcio Fernando Aparecido de, Namba,Mario, Silva,Joao Luiz Vieira da, Cunha,Luiz Antonio Munhoz da, Franco,Ana Paula Gebert de Oliveira, Costa,Isabel Ziesemer, Stieven Filho,Edmar
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Ortopedia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500417
Resumo: OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°.
id SBOT-2_1e464addd3bab0c81171a94499ea39af
oai_identifier_str oai:scielo:S0102-36162013000500417
network_acronym_str SBOT-2
network_name_str Revista Brasileira de Ortopedia (Online)
repository_id_str
spelling Hamstring tendons insertion - an anatomical studyAnatomyCadaverKnee OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°. Sociedade Brasileira de Ortopedia e Traumatologia2013-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500417Revista Brasileira de Ortopedia v.48 n.5 2013reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1016/j.rboe.2012.07.012info:eu-repo/semantics/openAccessGrassi,Cristiano AntonioFruheling,Vagner MessiasAbdo,Joao CaetanoMoura,Marcio Fernando Aparecido deNamba,MarioSilva,Joao Luiz Vieira daCunha,Luiz Antonio Munhoz daFranco,Ana Paula Gebert de OliveiraCosta,Isabel ZiesemerStieven Filho,Edmareng2014-02-25T00:00:00Zoai:scielo:S0102-36162013000500417Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2014-02-25T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Hamstring tendons insertion - an anatomical study
title Hamstring tendons insertion - an anatomical study
spellingShingle Hamstring tendons insertion - an anatomical study
Grassi,Cristiano Antonio
Anatomy
Cadaver
Knee
title_short Hamstring tendons insertion - an anatomical study
title_full Hamstring tendons insertion - an anatomical study
title_fullStr Hamstring tendons insertion - an anatomical study
title_full_unstemmed Hamstring tendons insertion - an anatomical study
title_sort Hamstring tendons insertion - an anatomical study
author Grassi,Cristiano Antonio
author_facet Grassi,Cristiano Antonio
Fruheling,Vagner Messias
Abdo,Joao Caetano
Moura,Marcio Fernando Aparecido de
Namba,Mario
Silva,Joao Luiz Vieira da
Cunha,Luiz Antonio Munhoz da
Franco,Ana Paula Gebert de Oliveira
Costa,Isabel Ziesemer
Stieven Filho,Edmar
author_role author
author2 Fruheling,Vagner Messias
Abdo,Joao Caetano
Moura,Marcio Fernando Aparecido de
Namba,Mario
Silva,Joao Luiz Vieira da
Cunha,Luiz Antonio Munhoz da
Franco,Ana Paula Gebert de Oliveira
Costa,Isabel Ziesemer
Stieven Filho,Edmar
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Grassi,Cristiano Antonio
Fruheling,Vagner Messias
Abdo,Joao Caetano
Moura,Marcio Fernando Aparecido de
Namba,Mario
Silva,Joao Luiz Vieira da
Cunha,Luiz Antonio Munhoz da
Franco,Ana Paula Gebert de Oliveira
Costa,Isabel Ziesemer
Stieven Filho,Edmar
dc.subject.por.fl_str_mv Anatomy
Cadaver
Knee
topic Anatomy
Cadaver
Knee
description OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°.
publishDate 2013
dc.date.none.fl_str_mv 2013-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500417
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500417
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.rboe.2012.07.012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
dc.source.none.fl_str_mv Revista Brasileira de Ortopedia v.48 n.5 2013
reponame:Revista Brasileira de Ortopedia (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Revista Brasileira de Ortopedia (Online)
collection Revista Brasileira de Ortopedia (Online)
repository.name.fl_str_mv Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv ||rbo@sbot.org.br
_version_ 1752122358777249792