Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial

Detalhes bibliográficos
Autor(a) principal: MADRUGA,Marina de Matos
Data de Publicação: 2017
Outros Autores: SILVA,Adriana Fernandes da, ROSA,Wellington Luiz de Oliveira da, PIVA,Evandro, LUND,Rafael Guerra
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100203
Resumo: Abstract A randomized, double-blind, split-mouth clinical trial was performed compared the desensitizing efficacy of the resin-modified glass ionomer cement (GIC) ClinproTM XT (3M ESPE, Minnesota, USA) and the conventional GIC Vidrion R (SS White, Gloucester, UK) in a 6-month follow-up. Subjects were required to have at least two teeth with dentin hypersensitivity. Teeth were divided at random into 2 groups, one group received Clinpro XT and the other conventional GIC Vidrion R. Treatments were assessed by tactile and air blast tests using Visual Analogue Scale (VAS) at baseline, after 20 minutes, and at 7, 15, 21, 30, 90 and 180 days post-treatment. Twenty subjects (152 teeth) were included. Both tests (tactile and air blast) showed a significant reduction of dentin hypersensitivity immediately after the application of Vidrion R and Clinpro XT (20 min). VAS scores obtained along the 6-month follow-up were statistically lower when compared to initial rates (p < 0.05). Both GIC were able to reduce dentin hypersensitivity up to 6-month post-treatment period without statistically significant differences among them (p > 0.05). Both cements provided satisfactory results in long-term dental sensitivity reduction.
id SBPQO-1_21bdc3e2f170d16cc80648f4bf1908d7
oai_identifier_str oai:scielo:S1806-83242017000100203
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trialDentin SensitivityDentin Desensitizing AgentsGlass Ionomer CementsRandomized Controlled TrialAbstract A randomized, double-blind, split-mouth clinical trial was performed compared the desensitizing efficacy of the resin-modified glass ionomer cement (GIC) ClinproTM XT (3M ESPE, Minnesota, USA) and the conventional GIC Vidrion R (SS White, Gloucester, UK) in a 6-month follow-up. Subjects were required to have at least two teeth with dentin hypersensitivity. Teeth were divided at random into 2 groups, one group received Clinpro XT and the other conventional GIC Vidrion R. Treatments were assessed by tactile and air blast tests using Visual Analogue Scale (VAS) at baseline, after 20 minutes, and at 7, 15, 21, 30, 90 and 180 days post-treatment. Twenty subjects (152 teeth) were included. Both tests (tactile and air blast) showed a significant reduction of dentin hypersensitivity immediately after the application of Vidrion R and Clinpro XT (20 min). VAS scores obtained along the 6-month follow-up were statistically lower when compared to initial rates (p < 0.05). Both GIC were able to reduce dentin hypersensitivity up to 6-month post-treatment period without statistically significant differences among them (p > 0.05). Both cements provided satisfactory results in long-term dental sensitivity reduction.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2017-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100203Brazilian Oral Research v.31 2017reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/1807-3107bor-2017.vol31.0003info:eu-repo/semantics/openAccessMADRUGA,Marina de MatosSILVA,Adriana Fernandes daROSA,Wellington Luiz de Oliveira daPIVA,EvandroLUND,Rafael Guerraeng2017-01-02T00:00:00Zoai:scielo:S1806-83242017000100203Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2017-01-02T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
title Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
spellingShingle Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
MADRUGA,Marina de Matos
Dentin Sensitivity
Dentin Desensitizing Agents
Glass Ionomer Cements
Randomized Controlled Trial
title_short Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
title_full Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
title_fullStr Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
title_full_unstemmed Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
title_sort Evaluation of dentin hypersensitivity treatment with glass ionomer cements: A randomized clinical trial
author MADRUGA,Marina de Matos
author_facet MADRUGA,Marina de Matos
SILVA,Adriana Fernandes da
ROSA,Wellington Luiz de Oliveira da
PIVA,Evandro
LUND,Rafael Guerra
author_role author
author2 SILVA,Adriana Fernandes da
ROSA,Wellington Luiz de Oliveira da
PIVA,Evandro
LUND,Rafael Guerra
author2_role author
author
author
author
dc.contributor.author.fl_str_mv MADRUGA,Marina de Matos
SILVA,Adriana Fernandes da
ROSA,Wellington Luiz de Oliveira da
PIVA,Evandro
LUND,Rafael Guerra
dc.subject.por.fl_str_mv Dentin Sensitivity
Dentin Desensitizing Agents
Glass Ionomer Cements
Randomized Controlled Trial
topic Dentin Sensitivity
Dentin Desensitizing Agents
Glass Ionomer Cements
Randomized Controlled Trial
description Abstract A randomized, double-blind, split-mouth clinical trial was performed compared the desensitizing efficacy of the resin-modified glass ionomer cement (GIC) ClinproTM XT (3M ESPE, Minnesota, USA) and the conventional GIC Vidrion R (SS White, Gloucester, UK) in a 6-month follow-up. Subjects were required to have at least two teeth with dentin hypersensitivity. Teeth were divided at random into 2 groups, one group received Clinpro XT and the other conventional GIC Vidrion R. Treatments were assessed by tactile and air blast tests using Visual Analogue Scale (VAS) at baseline, after 20 minutes, and at 7, 15, 21, 30, 90 and 180 days post-treatment. Twenty subjects (152 teeth) were included. Both tests (tactile and air blast) showed a significant reduction of dentin hypersensitivity immediately after the application of Vidrion R and Clinpro XT (20 min). VAS scores obtained along the 6-month follow-up were statistically lower when compared to initial rates (p < 0.05). Both GIC were able to reduce dentin hypersensitivity up to 6-month post-treatment period without statistically significant differences among them (p > 0.05). Both cements provided satisfactory results in long-term dental sensitivity reduction.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100203
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100203
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-3107bor-2017.vol31.0003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.31 2017
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318325213167616