ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422016000901131 |
Resumo: | A method for simultaneous analysis of phenylglyoxylic (PGA), mandelic (MA), hippuric (HA), orto-, meta- and para-methylhippuric (o-, m- and p-MHA) acids in urine, by high performance liquid chromatography with UV detection was developed and validated. The substances are biotransformation products used as biological indicators to assess the exposure of workers, respectively, to ethylbenzene, styrene, toluene and xylene. The urinary metabolites were separated using a C18 column and a mixture of 5 mM phosphate buffer pH 2.6:acetonitrile (92:8, v/v) as mobile phase. Urine samples were extracted with dichloromethane:ethyl acetate (70:30, v/v). The method used phenacetin as internal standard and was linear in the interval of 100-500 µg mL-1 for PGA and MA and 150-700 µg mL-1 for HA and MHA. The detection limits in µg mL-1, were 19.8 for PGA, 1.7 for MA, 4.1 for HA, 3.9 for o-MHA, 3.3 for m-MHA and 7.3 for p-MHA. Intra- and inter-assay precisions (as relative standard deviation) were all less than 15% and accuracy (as relative standard error) did not exceed 12.3%. The recovery was higher than 65% for all metabolites. The developed method will be applied to biological evaluation of workers exposure to these solvents. |
id |
SBQ-3_3107c98dcacce4e63f8eaa9359437b7b |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422016000901131 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UVvolatile organic compoundsurinebiological monitoringHPLC-UVA method for simultaneous analysis of phenylglyoxylic (PGA), mandelic (MA), hippuric (HA), orto-, meta- and para-methylhippuric (o-, m- and p-MHA) acids in urine, by high performance liquid chromatography with UV detection was developed and validated. The substances are biotransformation products used as biological indicators to assess the exposure of workers, respectively, to ethylbenzene, styrene, toluene and xylene. The urinary metabolites were separated using a C18 column and a mixture of 5 mM phosphate buffer pH 2.6:acetonitrile (92:8, v/v) as mobile phase. Urine samples were extracted with dichloromethane:ethyl acetate (70:30, v/v). The method used phenacetin as internal standard and was linear in the interval of 100-500 µg mL-1 for PGA and MA and 150-700 µg mL-1 for HA and MHA. The detection limits in µg mL-1, were 19.8 for PGA, 1.7 for MA, 4.1 for HA, 3.9 for o-MHA, 3.3 for m-MHA and 7.3 for p-MHA. Intra- and inter-assay precisions (as relative standard deviation) were all less than 15% and accuracy (as relative standard error) did not exceed 12.3%. The recovery was higher than 65% for all metabolites. The developed method will be applied to biological evaluation of workers exposure to these solvents.Sociedade Brasileira de Química2016-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422016000901131Química Nova v.39 n.9 2016reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0100-4042.20160128info:eu-repo/semantics/openAccessYamamoto,Priscila A.Moraes,Natália V. deSilva,Vinicius P.Lepera,José S.por2016-11-23T00:00:00Zoai:scielo:S0100-40422016000901131Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2016-11-23T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV |
title |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV |
spellingShingle |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV Yamamoto,Priscila A. volatile organic compounds urine biological monitoring HPLC-UV |
title_short |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV |
title_full |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV |
title_fullStr |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV |
title_full_unstemmed |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV |
title_sort |
ANÁLISE SIMULTÂNEA DOS INDICADORES BIOLÓGICOS DE EXPOSIÇÃO AOS SOLVENTES ETILBENZENO, ESTIRENO, TOLUENO E XILENO NA URINA POR CLAE-UV |
author |
Yamamoto,Priscila A. |
author_facet |
Yamamoto,Priscila A. Moraes,Natália V. de Silva,Vinicius P. Lepera,José S. |
author_role |
author |
author2 |
Moraes,Natália V. de Silva,Vinicius P. Lepera,José S. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Yamamoto,Priscila A. Moraes,Natália V. de Silva,Vinicius P. Lepera,José S. |
dc.subject.por.fl_str_mv |
volatile organic compounds urine biological monitoring HPLC-UV |
topic |
volatile organic compounds urine biological monitoring HPLC-UV |
description |
A method for simultaneous analysis of phenylglyoxylic (PGA), mandelic (MA), hippuric (HA), orto-, meta- and para-methylhippuric (o-, m- and p-MHA) acids in urine, by high performance liquid chromatography with UV detection was developed and validated. The substances are biotransformation products used as biological indicators to assess the exposure of workers, respectively, to ethylbenzene, styrene, toluene and xylene. The urinary metabolites were separated using a C18 column and a mixture of 5 mM phosphate buffer pH 2.6:acetonitrile (92:8, v/v) as mobile phase. Urine samples were extracted with dichloromethane:ethyl acetate (70:30, v/v). The method used phenacetin as internal standard and was linear in the interval of 100-500 µg mL-1 for PGA and MA and 150-700 µg mL-1 for HA and MHA. The detection limits in µg mL-1, were 19.8 for PGA, 1.7 for MA, 4.1 for HA, 3.9 for o-MHA, 3.3 for m-MHA and 7.3 for p-MHA. Intra- and inter-assay precisions (as relative standard deviation) were all less than 15% and accuracy (as relative standard error) did not exceed 12.3%. The recovery was higher than 65% for all metabolites. The developed method will be applied to biological evaluation of workers exposure to these solvents. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-11-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422016000901131 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422016000901131 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
10.21577/0100-4042.20160128 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.39 n.9 2016 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318117913886720 |