Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400027 |
Resumo: | This study reports on the construction of a turbidimeter employing light emitting diodes as radiation source at a wavelength of 405 nm, a photodiode as detector, a temperature sensor and a microcontroller used for data acquisition and processing. The turbidimeter was applied to determine sulfate concentrations in natural water employing barium chloride as reagent. Potential interferences and recovery studies were performed and an interference of 3.5 % and a recovery between 97.8 and 108 % were estimated. The analytical performance of in situ turbidimeter for the determination of sulfate was evaluated and compared with two commercial spectrophotometers and a good agreement was obtained. |
id |
SBQ-3_5be6ec0bf9ac53b44ec791f027e8db2c |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422012000400027 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfateturbidimetryin situ analysessulfate determinationThis study reports on the construction of a turbidimeter employing light emitting diodes as radiation source at a wavelength of 405 nm, a photodiode as detector, a temperature sensor and a microcontroller used for data acquisition and processing. The turbidimeter was applied to determine sulfate concentrations in natural water employing barium chloride as reagent. Potential interferences and recovery studies were performed and an interference of 3.5 % and a recovery between 97.8 and 108 % were estimated. The analytical performance of in situ turbidimeter for the determination of sulfate was evaluated and compared with two commercial spectrophotometers and a good agreement was obtained.Sociedade Brasileira de Química2012-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400027Química Nova v.35 n.4 2012reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422012000400027info:eu-repo/semantics/openAccessSantos,Vagner B. dosGuerreiro,Thiago B.Faria,Ronaldo C.Fatibello-Filho,OrlandoSuarez,Willian T.eng2012-05-28T00:00:00Zoai:scielo:S0100-40422012000400027Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2012-05-28T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate |
title |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate |
spellingShingle |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate Santos,Vagner B. dos turbidimetry in situ analyses sulfate determination |
title_short |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate |
title_full |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate |
title_fullStr |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate |
title_full_unstemmed |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate |
title_sort |
Construction and application of a portable microcontrolled turbidimeter for the in situ determination of sulfate |
author |
Santos,Vagner B. dos |
author_facet |
Santos,Vagner B. dos Guerreiro,Thiago B. Faria,Ronaldo C. Fatibello-Filho,Orlando Suarez,Willian T. |
author_role |
author |
author2 |
Guerreiro,Thiago B. Faria,Ronaldo C. Fatibello-Filho,Orlando Suarez,Willian T. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Santos,Vagner B. dos Guerreiro,Thiago B. Faria,Ronaldo C. Fatibello-Filho,Orlando Suarez,Willian T. |
dc.subject.por.fl_str_mv |
turbidimetry in situ analyses sulfate determination |
topic |
turbidimetry in situ analyses sulfate determination |
description |
This study reports on the construction of a turbidimeter employing light emitting diodes as radiation source at a wavelength of 405 nm, a photodiode as detector, a temperature sensor and a microcontroller used for data acquisition and processing. The turbidimeter was applied to determine sulfate concentrations in natural water employing barium chloride as reagent. Potential interferences and recovery studies were performed and an interference of 3.5 % and a recovery between 97.8 and 108 % were estimated. The analytical performance of in situ turbidimeter for the determination of sulfate was evaluated and compared with two commercial spectrophotometers and a good agreement was obtained. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400027 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000400027 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-40422012000400027 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.35 n.4 2012 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318113466875904 |