Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes

Detalhes bibliográficos
Autor(a) principal: Machado, Raquel Cardoso
Data de Publicação: 2018
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/10653
Resumo: Each year, Brazil sets records on agricultural productivity, which significantly increases the use of fertilizers in crops to provide the essential nutrientes. However, fertilizers can also be sources of toxic elements from the raw material and manufacturing processes, which can be absorbed by crops. In this thesis, different strategies were adopted to the development of analytical methods employing tniques with plasma sources, as microwave induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma mass spectrometry with a tandem mass configuration (ICP-MS/MS), and direct solids analysis using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) for fertilizers analysis, overcoming spectral and non-spectral interferences. The hydride generation coupling to MIP OES (HG-MIP OES) favored the determination of As, Bi, Ge, Sb, and Sn in fertilizer samples, with recovery of 106 % for As obtained from the certified reference material (CRM) NIST 695 and recoveries between 90 and 118 % from addition and recovery experiments. Silicon in fertilizers was determined by MIP OES using air addition into the N2 plasma after microwave-assisted digestion in acid and alkaline médium. The air addition into the N2 plasma render it more robust against the addition of electrons in the plasma due to the presense of Na, which is easily ionizable. The Si results obtained by MIP OES were compared with reference values obtained by X-ray fluorescence (XRF) and inductively coupled plasma optical emission spectrometry (ICP OES). The recoveries between 80 and 89 % without and 97 and 100 % with air addition were obtainde, respectively. In another study, a multi-energy calibration method (MEC) with matrix-matching capability was evaluated for fertilizer analysis by MIP OES. This strategy was effective for determination of As, Cd, Ba, Cr and Pb in mineral fertilizers, whose recoveries ranged from 96 to 101 % in fertilizer reference material (NIST 695) for As, Ba, Cr, and Pb and from 92 to 105 % for Cd in addition and recovery experiments in fertilizer samples. In fertilizers analysis by ICP-MS/MS, free-interference determinations were obtained for Cd and Sn, and for platinum group metals, such as Pd, Pt, and Rh, Rhodium and Pt were determined from the mode MS/MS mass-shift and Cd, Pd, and Sn were determined from the mode MS/MS on mass. To evaluate the accuracy, addition and recovery experiments at three concentration levels were performed and recoveries between 81 and 102 %, and 80 to 113 % were obtained for the MS/MS mass-shift mode and MS/MS on mass, respectively. Direct analysis of fertilizers solids was proposed for the simultaneous determination of Co, Cr, Fe, and Ni by HR-CS GFAAS, using in situ microfusion procedure to matriz elimination. The monitoring of the spectral region around the wavelength 298.560 nm allowed simultaneous determination of analytes, employing aqueous solutions for calibration. Applying the method developed, recoveries ranged from 81 and 120 % were obtained for direct analysis of CRM NIST 695.
id SCAR_cf62fa768c702463dfb34eb75626cfb0
oai_identifier_str oai:repositorio.ufscar.br:ufscar/10653
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Machado, Raquel CardosoNogueira, Ana Rita de Araújohttp://lattes.cnpq.br/7034773971317045Resano, Martínhttp://www.researcherid.com/rid/E-6195-2012http://lattes.cnpq.br/67446632358981887823f8b8-013a-4e27-804f-8f7a4fc45f5a2018-11-08T12:55:28Z2018-11-08T12:55:28Z2018-04-26MACHADO, Raquel Cardoso. Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes. 2018. Tese (Doutorado em Química) – Universidade Federal de São Carlos, São Carlos, 2018. Disponível em: https://repositorio.ufscar.br/handle/ufscar/10653.https://repositorio.ufscar.br/handle/ufscar/10653Each year, Brazil sets records on agricultural productivity, which significantly increases the use of fertilizers in crops to provide the essential nutrientes. However, fertilizers can also be sources of toxic elements from the raw material and manufacturing processes, which can be absorbed by crops. In this thesis, different strategies were adopted to the development of analytical methods employing tniques with plasma sources, as microwave induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma mass spectrometry with a tandem mass configuration (ICP-MS/MS), and direct solids analysis using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) for fertilizers analysis, overcoming spectral and non-spectral interferences. The hydride generation coupling to MIP OES (HG-MIP OES) favored the determination of As, Bi, Ge, Sb, and Sn in fertilizer samples, with recovery of 106 % for As obtained from the certified reference material (CRM) NIST 695 and recoveries between 90 and 118 % from addition and recovery experiments. Silicon in fertilizers was determined by MIP OES using air addition into the N2 plasma after microwave-assisted digestion in acid and alkaline médium. The air addition into the N2 plasma render it more robust against the addition of electrons in the plasma due to the presense of Na, which is easily ionizable. The Si results obtained by MIP OES were compared with reference values obtained by X-ray fluorescence (XRF) and inductively coupled plasma optical emission spectrometry (ICP OES). The recoveries between 80 and 89 % without and 97 and 100 % with air addition were obtainde, respectively. In another study, a multi-energy calibration method (MEC) with matrix-matching capability was evaluated for fertilizer analysis by MIP OES. This strategy was effective for determination of As, Cd, Ba, Cr and Pb in mineral fertilizers, whose recoveries ranged from 96 to 101 % in fertilizer reference material (NIST 695) for As, Ba, Cr, and Pb and from 92 to 105 % for Cd in addition and recovery experiments in fertilizer samples. In fertilizers analysis by ICP-MS/MS, free-interference determinations were obtained for Cd and Sn, and for platinum group metals, such as Pd, Pt, and Rh, Rhodium and Pt were determined from the mode MS/MS mass-shift and Cd, Pd, and Sn were determined from the mode MS/MS on mass. To evaluate the accuracy, addition and recovery experiments at three concentration levels were performed and recoveries between 81 and 102 %, and 80 to 113 % were obtained for the MS/MS mass-shift mode and MS/MS on mass, respectively. Direct analysis of fertilizers solids was proposed for the simultaneous determination of Co, Cr, Fe, and Ni by HR-CS GFAAS, using in situ microfusion procedure to matriz elimination. The monitoring of the spectral region around the wavelength 298.560 nm allowed simultaneous determination of analytes, employing aqueous solutions for calibration. Applying the method developed, recoveries ranged from 81 and 120 % were obtained for direct analysis of CRM NIST 695.A cada ano, o Brasil bate recordes na produtividade agrícola, o que aumenta consideravelmente o uso de fertilizantes nas lavouras para fornecer os nutrientes essenciais. Entretanto, fertilizantes também podem ser fontes de elementos tóxicos provenientes da matéria-prima e dos processos de fabricação, os quais podem ser absorvidos pelas culturas. Nesta tese de doutorado, diferentes estratégias foram adotadas no desenvolvimento de métodos analíticos empregando técnicas com fonte de plasma como espectrometria de emissão óptica com plasma induzido por micro-ondas (MIP OES) e espectrometria de massas com plasma acoplado indutivamente e configuração tandem (ICP-MS/MS) e análise direta de sólidos usando a espectrometria de absorção atômica em forno de grafite com fonte contínua e alta resolução (HR CS GFAAS) para análise de fertilizantes, buscando superar interferências espectrais e não espectrais. O acoplamento da geração de hidretos ao MIP OES (HG-MIP OES) favoreceu a determinação de As, Bi, Ge, Sb e Sn em amostras de fertilizantes obtendo-se recuperação de 106 % para As usando o material de referência certificado (CRM) NIST 695 e recuperações entre 90 a 118% a partir dos experimentos de adição e recuperação de analito. Silício foi determinado por MIP OES usando adição de ar no plasma de N2 depois de uma digestão assistida por radiação micro-ondas nos meios ácido e básico. A adição de ar no plasma de N2 torna-o mais robusto frente à adição de elétrons no plasma devido à presença do Na, que é um elemento facilmente ionizável. Os resultados obtidos por MIP OES foram comparados com os valores de referência obtidos por fluorescência de raios-X (XRF) e por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). As recuperações variaram entre 80 e 89 % sem e 97 e 100 % com adição de ar, respectivamente. Em outro estudo, a calibração por multiplas energias (MEC) com capacidade de compatibilização de matriz foi avaliada para análise de fertilizantes por MIP OES. Esssa estratégia foi efetiva para determinação de As, Cd, Ba, Cr e Pb em fertilizantes minerais, com recuperações na faixa de 96 a 101 % para As, Ba, Cr e Pb no CRM NIST 695 e entre 92 a 105 % para Cd no experimento de adição e recuperação para Cd nas amostras de fertilizantes. Na análise de fertilizantes por ICP-MS/MS, determinações livres de interferências foram obtidas para Cd e Sn e para metais do grupo da platina, como Pd, Pt e Rh. Ródio e Pt foram determinados a partir do modo MS/MS mass-shift e Cd, Pd e Sn foram determinados pelo uso do modo MS/MS on mass. Para avaliar a exatidão, experimentos de adição e recuperação em três níveis de concentração foram realizados e recuperações entre 81 e 102 % e 80 e 113 % foram obtidos para os modos MS/MS mass-shift e MS/MS on mass, respectivamente. Análise direta de fertilizantes sólidos foi proposta para a determinação simultânea de Co, Cr, Fe e Ni por HR-CS GFAAS, usando um procedimento de microfusão in situ para eliminação da matriz. O monitoramento da região espectral próximo ao comprimento de onda 298,560 nm permitiu a determinação simultânea dos analitos, empregando a calibração por meio de soluções aquosos foi usada. Aplicando o método desenvolvido, recuperações entre 81 e 120 % foram obtidas pela análise direta do CRM NIST 695.OutraFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)BEPE: 2016/07749-5FAPESP: 2013/26672-5porUniversidade Federal de São CarlosCâmpus São CarlosPrograma de Pós-Graduação em Química - PPGQUFSCarFertilizantePlasma de nitrogênioMIP OESICP-MSHR-CS GFAASAnálise direta de sólidosInterferência espectralInterferência não espectralEfeito de matrizFertilizerNitrogen plasmaDirect solid samplingNon-spectral interferenceSpectral interferenceMatrix effectCIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::INSTRUMENTACAO ANALITICACIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::METODOS OTICOS DE ANALISEPotencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantesPotencialidades de las técnicas con fuente de plasma y de la espectrometría de absorción atómica en horno de grafito de alta resolución con fuente continua para análisis de fertilizantesPotentialities of plasma source techniques and high resolution continuum source graphite furnace atomic absorption spectrometry for fertilizers analysisinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisOnline600e83fd9a0-c0d6-4518-b677-9aa885aeffbcinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINALTese_RCM_versão final.pdfTese_RCM_versão final.pdfapplication/pdf2894168https://repositorio.ufscar.br/bitstream/ufscar/10653/1/Tese_RCM_vers%c3%a3o%20final.pdfb547136c4b520ac11d25c364855b7866MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81957https://repositorio.ufscar.br/bitstream/ufscar/10653/4/license.txtae0398b6f8b235e40ad82cba6c50031dMD54TEXTTese_RCM_versão final.pdf.txtTese_RCM_versão final.pdf.txtExtracted texttext/plain226639https://repositorio.ufscar.br/bitstream/ufscar/10653/5/Tese_RCM_vers%c3%a3o%20final.pdf.txtb50913af022f1d78ab8c40b7a1bbd2e5MD55THUMBNAILTese_RCM_versão final.pdf.jpgTese_RCM_versão final.pdf.jpgIM Thumbnailimage/jpeg11237https://repositorio.ufscar.br/bitstream/ufscar/10653/6/Tese_RCM_vers%c3%a3o%20final.pdf.jpg178076ec32887e6a41d1a47d4113228eMD56ufscar/106532023-09-18 18:31:17.909oai:repositorio.ufscar.br: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Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:17Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
dc.title.alternative.spa.fl_str_mv Potencialidades de las técnicas con fuente de plasma y de la espectrometría de absorción atómica en horno de grafito de alta resolución con fuente continua para análisis de fertilizantes
dc.title.alternative.eng.fl_str_mv Potentialities of plasma source techniques and high resolution continuum source graphite furnace atomic absorption spectrometry for fertilizers analysis
title Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
spellingShingle Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
Machado, Raquel Cardoso
Fertilizante
Plasma de nitrogênio
MIP OES
ICP-MS
HR-CS GFAAS
Análise direta de sólidos
Interferência espectral
Interferência não espectral
Efeito de matriz
Fertilizer
Nitrogen plasma
Direct solid sampling
Non-spectral interference
Spectral interference
Matrix effect
CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::INSTRUMENTACAO ANALITICA
CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::METODOS OTICOS DE ANALISE
title_short Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
title_full Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
title_fullStr Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
title_full_unstemmed Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
title_sort Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes
author Machado, Raquel Cardoso
author_facet Machado, Raquel Cardoso
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/6744663235898188
dc.contributor.author.fl_str_mv Machado, Raquel Cardoso
dc.contributor.advisor1.fl_str_mv Nogueira, Ana Rita de Araújo
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/7034773971317045
dc.contributor.advisor-co1.fl_str_mv Resano, Martín
dc.contributor.advisor-co1Lattes.fl_str_mv http://www.researcherid.com/rid/E-6195-2012
dc.contributor.authorID.fl_str_mv 7823f8b8-013a-4e27-804f-8f7a4fc45f5a
contributor_str_mv Nogueira, Ana Rita de Araújo
Resano, Martín
dc.subject.por.fl_str_mv Fertilizante
Plasma de nitrogênio
MIP OES
ICP-MS
HR-CS GFAAS
Análise direta de sólidos
Interferência espectral
Interferência não espectral
Efeito de matriz
Fertilizer
topic Fertilizante
Plasma de nitrogênio
MIP OES
ICP-MS
HR-CS GFAAS
Análise direta de sólidos
Interferência espectral
Interferência não espectral
Efeito de matriz
Fertilizer
Nitrogen plasma
Direct solid sampling
Non-spectral interference
Spectral interference
Matrix effect
CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::INSTRUMENTACAO ANALITICA
CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::METODOS OTICOS DE ANALISE
dc.subject.eng.fl_str_mv Nitrogen plasma
Direct solid sampling
Non-spectral interference
Spectral interference
Matrix effect
dc.subject.cnpq.fl_str_mv CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::INSTRUMENTACAO ANALITICA
CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::METODOS OTICOS DE ANALISE
description Each year, Brazil sets records on agricultural productivity, which significantly increases the use of fertilizers in crops to provide the essential nutrientes. However, fertilizers can also be sources of toxic elements from the raw material and manufacturing processes, which can be absorbed by crops. In this thesis, different strategies were adopted to the development of analytical methods employing tniques with plasma sources, as microwave induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma mass spectrometry with a tandem mass configuration (ICP-MS/MS), and direct solids analysis using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) for fertilizers analysis, overcoming spectral and non-spectral interferences. The hydride generation coupling to MIP OES (HG-MIP OES) favored the determination of As, Bi, Ge, Sb, and Sn in fertilizer samples, with recovery of 106 % for As obtained from the certified reference material (CRM) NIST 695 and recoveries between 90 and 118 % from addition and recovery experiments. Silicon in fertilizers was determined by MIP OES using air addition into the N2 plasma after microwave-assisted digestion in acid and alkaline médium. The air addition into the N2 plasma render it more robust against the addition of electrons in the plasma due to the presense of Na, which is easily ionizable. The Si results obtained by MIP OES were compared with reference values obtained by X-ray fluorescence (XRF) and inductively coupled plasma optical emission spectrometry (ICP OES). The recoveries between 80 and 89 % without and 97 and 100 % with air addition were obtainde, respectively. In another study, a multi-energy calibration method (MEC) with matrix-matching capability was evaluated for fertilizer analysis by MIP OES. This strategy was effective for determination of As, Cd, Ba, Cr and Pb in mineral fertilizers, whose recoveries ranged from 96 to 101 % in fertilizer reference material (NIST 695) for As, Ba, Cr, and Pb and from 92 to 105 % for Cd in addition and recovery experiments in fertilizer samples. In fertilizers analysis by ICP-MS/MS, free-interference determinations were obtained for Cd and Sn, and for platinum group metals, such as Pd, Pt, and Rh, Rhodium and Pt were determined from the mode MS/MS mass-shift and Cd, Pd, and Sn were determined from the mode MS/MS on mass. To evaluate the accuracy, addition and recovery experiments at three concentration levels were performed and recoveries between 81 and 102 %, and 80 to 113 % were obtained for the MS/MS mass-shift mode and MS/MS on mass, respectively. Direct analysis of fertilizers solids was proposed for the simultaneous determination of Co, Cr, Fe, and Ni by HR-CS GFAAS, using in situ microfusion procedure to matriz elimination. The monitoring of the spectral region around the wavelength 298.560 nm allowed simultaneous determination of analytes, employing aqueous solutions for calibration. Applying the method developed, recoveries ranged from 81 and 120 % were obtained for direct analysis of CRM NIST 695.
publishDate 2018
dc.date.accessioned.fl_str_mv 2018-11-08T12:55:28Z
dc.date.available.fl_str_mv 2018-11-08T12:55:28Z
dc.date.issued.fl_str_mv 2018-04-26
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv MACHADO, Raquel Cardoso. Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes. 2018. Tese (Doutorado em Química) – Universidade Federal de São Carlos, São Carlos, 2018. Disponível em: https://repositorio.ufscar.br/handle/ufscar/10653.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/10653
identifier_str_mv MACHADO, Raquel Cardoso. Potencialidades das técnicas com fonte de plasma e da espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua para análise de fertilizantes. 2018. Tese (Doutorado em Química) – Universidade Federal de São Carlos, São Carlos, 2018. Disponível em: https://repositorio.ufscar.br/handle/ufscar/10653.
url https://repositorio.ufscar.br/handle/ufscar/10653
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv 600
dc.relation.authority.fl_str_mv e83fd9a0-c0d6-4518-b677-9aa885aeffbc
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Química - PPGQ
dc.publisher.initials.fl_str_mv UFSCar
publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/10653/1/Tese_RCM_vers%c3%a3o%20final.pdf
https://repositorio.ufscar.br/bitstream/ufscar/10653/4/license.txt
https://repositorio.ufscar.br/bitstream/ufscar/10653/5/Tese_RCM_vers%c3%a3o%20final.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/10653/6/Tese_RCM_vers%c3%a3o%20final.pdf.jpg
bitstream.checksum.fl_str_mv b547136c4b520ac11d25c364855b7866
ae0398b6f8b235e40ad82cba6c50031d
b50913af022f1d78ab8c40b7a1bbd2e5
178076ec32887e6a41d1a47d4113228e
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1802136349259595776