Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFOP |
Texto Completo: | http://www.repositorio.ufop.br/handle/123456789/9145 https://doi.org/10.1016/j.enbuild.2017.04.049 |
Resumo: | Complete knowledge about habits of the occupants, including their opinions regarding ventilation systems is an important condition for reducing the consumption of natural resources and improving indoor comfort. In addition, uncomforted occupants tend to take measures to improve their situation, which may increase energy consumption. Advanced thermal models for buildings can perhaps predict interactions between the IAQ determinants, e.g. energy consumption, ventilation and comfort, but do not take into account the behavior of residents. By questionnaires and physical measurements this study evaluated dwellings equipped partly with centralized and partly with decentralized ventilation systems with heat recovery. This field study involved two post-occupied residential buildings situated in the city of Esch-sur-Alzette, Luxembourg, during spring season 2015. Thus, both the physical measurements and questionnaires were considered. The results obtained demonstrated that more than 80% of the residents were satisfied and the perceived IAQ was judged “normal”, “good” or even “very good”. Further more, the measurements performed detected in some cases malfunction of ventilation devices, wherefore the occupants were unable. |
id |
UFOP_f5b239a3d87aa8beb5c7bed9e7c3778f |
---|---|
oai_identifier_str |
oai:localhost:123456789/9145 |
network_acronym_str |
UFOP |
network_name_str |
Repositório Institucional da UFOP |
repository_id_str |
3233 |
spelling |
Silva, Marielle FerreiraMaas, StefanSouza, Henor Artur deGomes, Adriano Pinto2017-11-14T12:16:15Z2017-11-14T12:16:15Z2017SILVA, M. F. et al. Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. Energy and Buildings, v. 148, p. 119-127, 2017. Disponível em: <http://www.sciencedirect.com/science/article/pii/S0378778817313968>. Acesso em: 29 set. 2017.0378-7788http://www.repositorio.ufop.br/handle/123456789/9145https://doi.org/10.1016/j.enbuild.2017.04.049Complete knowledge about habits of the occupants, including their opinions regarding ventilation systems is an important condition for reducing the consumption of natural resources and improving indoor comfort. In addition, uncomforted occupants tend to take measures to improve their situation, which may increase energy consumption. Advanced thermal models for buildings can perhaps predict interactions between the IAQ determinants, e.g. energy consumption, ventilation and comfort, but do not take into account the behavior of residents. By questionnaires and physical measurements this study evaluated dwellings equipped partly with centralized and partly with decentralized ventilation systems with heat recovery. This field study involved two post-occupied residential buildings situated in the city of Esch-sur-Alzette, Luxembourg, during spring season 2015. Thus, both the physical measurements and questionnaires were considered. The results obtained demonstrated that more than 80% of the residents were satisfied and the perceived IAQ was judged “normal”, “good” or even “very good”. Further more, the measurements performed detected in some cases malfunction of ventilation devices, wherefore the occupants were unable.Indoor air qualityPost-occupancy evaluationResidential buildingsCentralized and decentralized mechanical ventilationPost-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements.info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleinfo:eu-repo/semantics/openAccessengreponame:Repositório Institucional da UFOPinstname:Universidade Federal de Ouro Preto (UFOP)instacron:UFOPLICENSElicense.txtlicense.txttext/plain; charset=utf-8924http://www.repositorio.ufop.br/bitstream/123456789/9145/2/license.txt62604f8d955274beb56c80ce1ee5dcaeMD52ORIGINALARTIGO_PostOccupancyEvaluation.pdfARTIGO_PostOccupancyEvaluation.pdfapplication/pdf2768842http://www.repositorio.ufop.br/bitstream/123456789/9145/1/ARTIGO_PostOccupancyEvaluation.pdff0da7b0e0e8fc3be2396cbc24a241ad8MD51123456789/91452020-02-19 10:06:05.648oai:localhost: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ório InstitucionalPUBhttp://www.repositorio.ufop.br/oai/requestrepositorio@ufop.edu.bropendoar:32332020-02-19T15:06:05Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP)false |
dc.title.pt_BR.fl_str_mv |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. |
title |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. |
spellingShingle |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. Silva, Marielle Ferreira Indoor air quality Post-occupancy evaluation Residential buildings Centralized and decentralized mechanical ventilation |
title_short |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. |
title_full |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. |
title_fullStr |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. |
title_full_unstemmed |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. |
title_sort |
Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. |
author |
Silva, Marielle Ferreira |
author_facet |
Silva, Marielle Ferreira Maas, Stefan Souza, Henor Artur de Gomes, Adriano Pinto |
author_role |
author |
author2 |
Maas, Stefan Souza, Henor Artur de Gomes, Adriano Pinto |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Silva, Marielle Ferreira Maas, Stefan Souza, Henor Artur de Gomes, Adriano Pinto |
dc.subject.por.fl_str_mv |
Indoor air quality Post-occupancy evaluation Residential buildings Centralized and decentralized mechanical ventilation |
topic |
Indoor air quality Post-occupancy evaluation Residential buildings Centralized and decentralized mechanical ventilation |
description |
Complete knowledge about habits of the occupants, including their opinions regarding ventilation systems is an important condition for reducing the consumption of natural resources and improving indoor comfort. In addition, uncomforted occupants tend to take measures to improve their situation, which may increase energy consumption. Advanced thermal models for buildings can perhaps predict interactions between the IAQ determinants, e.g. energy consumption, ventilation and comfort, but do not take into account the behavior of residents. By questionnaires and physical measurements this study evaluated dwellings equipped partly with centralized and partly with decentralized ventilation systems with heat recovery. This field study involved two post-occupied residential buildings situated in the city of Esch-sur-Alzette, Luxembourg, during spring season 2015. Thus, both the physical measurements and questionnaires were considered. The results obtained demonstrated that more than 80% of the residents were satisfied and the perceived IAQ was judged “normal”, “good” or even “very good”. Further more, the measurements performed detected in some cases malfunction of ventilation devices, wherefore the occupants were unable. |
publishDate |
2017 |
dc.date.accessioned.fl_str_mv |
2017-11-14T12:16:15Z |
dc.date.available.fl_str_mv |
2017-11-14T12:16:15Z |
dc.date.issued.fl_str_mv |
2017 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
SILVA, M. F. et al. Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. Energy and Buildings, v. 148, p. 119-127, 2017. Disponível em: <http://www.sciencedirect.com/science/article/pii/S0378778817313968>. Acesso em: 29 set. 2017. |
dc.identifier.uri.fl_str_mv |
http://www.repositorio.ufop.br/handle/123456789/9145 |
dc.identifier.issn.none.fl_str_mv |
0378-7788 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1016/j.enbuild.2017.04.049 |
identifier_str_mv |
SILVA, M. F. et al. Post-occupancy evaluation of residential buildings in Luxembourg with centralized and decentralized ventilation systems, focusing onindoor air quality (IAQ). Assessment by questionnaires and physical measurements. Energy and Buildings, v. 148, p. 119-127, 2017. Disponível em: <http://www.sciencedirect.com/science/article/pii/S0378778817313968>. Acesso em: 29 set. 2017. 0378-7788 |
url |
http://www.repositorio.ufop.br/handle/123456789/9145 https://doi.org/10.1016/j.enbuild.2017.04.049 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFOP instname:Universidade Federal de Ouro Preto (UFOP) instacron:UFOP |
instname_str |
Universidade Federal de Ouro Preto (UFOP) |
instacron_str |
UFOP |
institution |
UFOP |
reponame_str |
Repositório Institucional da UFOP |
collection |
Repositório Institucional da UFOP |
bitstream.url.fl_str_mv |
http://www.repositorio.ufop.br/bitstream/123456789/9145/2/license.txt http://www.repositorio.ufop.br/bitstream/123456789/9145/1/ARTIGO_PostOccupancyEvaluation.pdf |
bitstream.checksum.fl_str_mv |
62604f8d955274beb56c80ce1ee5dcae f0da7b0e0e8fc3be2396cbc24a241ad8 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP) |
repository.mail.fl_str_mv |
repositorio@ufop.edu.br |
_version_ |
1801685772548440064 |