Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco

Detalhes bibliográficos
Autor(a) principal: Coutinho, Karilany Dantas
Data de Publicação: 2014
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFRN
Texto Completo: https://repositorio.ufrn.br/jspui/handle/123456789/15608
Resumo: In recent years there has been a significant growth in technologies that modify implant surfaces, reducing healing time and allowing their successful use in areas with low bone density. One of the most widely used techniques is plasma nitration, applied with excellent results in titanium and its alloys, with greater frequency in the manufacture of hip, ankle and shoulder implants. However, its use in dental implants is very limited due to high process temperatures (between 700 C o and 800 C o ), resulting in distortions in these geometrically complex and highly precise components. The aim of the present study is to assess osseointegration and mechanical strength of grade II nitrided titanium samples, through configuration of hollow cathode discharge. Moreover, new formulations are proposed to determine the optimum structural topology of the dental implant under study, in order to perfect its shape, make it efficient, competitive and with high definition. In the nitriding process, the samples were treated at a temperature of 450 C o and pressure of 150 Pa , during 1 hour of treatment. This condition was selected because it obtains the best wettability results in previous studies, where different pressure, temperature and time conditions were systematized. The samples were characterized by X-ray diffraction, scanning electron microscope, roughness, microhardness and wettability. Biomechanical fatigue tests were then conducted. Finally, a formulation using the three dimensional structural topology optimization method was proposed, in conjunction with an hadaptive refinement process. The results showed that plasma nitriding, using the hollow cathode discharge technique, caused changes in the surface texture of test specimens, increases surface roughness, wettability and microhardness when compared to the untreated sample. In the biomechanical fatigue test, the treated implant showed no flaws, after five million cycles, at a maximum fatigue load of 84.46 N. The results of the topological optimization process showed well-defined optimized layouts of the dental implant, with a clear distribution of material and a defined edge
id UFRN_74d3a0e90e8e29c8cd390671e8836a63
oai_identifier_str oai:https://repositorio.ufrn.br:123456789/15608
network_acronym_str UFRN
network_name_str Repositório Institucional da UFRN
repository_id_str
spelling Coutinho, Karilany Dantashttp://lattes.cnpq.br/8409211766785367http://lattes.cnpq.br/5028446242533356Guerra Neto, Custódio Leopoldino Britohttp://lattes.cnpq.br/5387010100082241Freire Júnior, Raimundo Carlos Silvériohttp://lattes.cnpq.br/1042806990155996Wanderley, Caroline Dantas Vilarhttp://lattes.cnpq.br/7861700022912054Costa, Thércio Henrique de Carvalhohttp://lattes.cnpq.br/3647710047561421Costa Júnior, João Carlos Arantes2014-12-17T14:57:58Z2014-10-232014-12-17T14:57:58Z2014-06-10COUTINHO, Karilany Dantas. Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco. 2014. 225 f. Tese (Doutorado em Tecnologia de Materiais; Projetos Mecânicos; Termociências) - Universidade Federal do Rio Grande do Norte, Natal, 2014.https://repositorio.ufrn.br/jspui/handle/123456789/15608In recent years there has been a significant growth in technologies that modify implant surfaces, reducing healing time and allowing their successful use in areas with low bone density. One of the most widely used techniques is plasma nitration, applied with excellent results in titanium and its alloys, with greater frequency in the manufacture of hip, ankle and shoulder implants. However, its use in dental implants is very limited due to high process temperatures (between 700 C o and 800 C o ), resulting in distortions in these geometrically complex and highly precise components. The aim of the present study is to assess osseointegration and mechanical strength of grade II nitrided titanium samples, through configuration of hollow cathode discharge. Moreover, new formulations are proposed to determine the optimum structural topology of the dental implant under study, in order to perfect its shape, make it efficient, competitive and with high definition. In the nitriding process, the samples were treated at a temperature of 450 C o and pressure of 150 Pa , during 1 hour of treatment. This condition was selected because it obtains the best wettability results in previous studies, where different pressure, temperature and time conditions were systematized. The samples were characterized by X-ray diffraction, scanning electron microscope, roughness, microhardness and wettability. Biomechanical fatigue tests were then conducted. Finally, a formulation using the three dimensional structural topology optimization method was proposed, in conjunction with an hadaptive refinement process. The results showed that plasma nitriding, using the hollow cathode discharge technique, caused changes in the surface texture of test specimens, increases surface roughness, wettability and microhardness when compared to the untreated sample. In the biomechanical fatigue test, the treated implant showed no flaws, after five million cycles, at a maximum fatigue load of 84.46 N. The results of the topological optimization process showed well-defined optimized layouts of the dental implant, with a clear distribution of material and a defined edgeNos últimos anos tem-se observado um grande crescimento em tecnologias para modificação de superfícies de implantes que reduzam o tempo de espera da cicatrização, assim como possibilite seu uso com sucesso em áreas de baixa densidade óssea. Dentre as diferentes técnicas, a nitretação por plasma desponta como forte candidata, uma vez que a mesma já está sendo empregada com excelentes resultados no titânio e suas ligas, aplicados com maior frequência na confecção de implantes de quadril, ombro e tornozelo. Entretanto, seu uso em implantes dentários é bastante limitado devido às altas temperaturas do processo (entre 700 C o e 800 C o ) resultando em distorções nessas peças que possuem geometria complexa e alto grau de precisão. O objetivo deste trabalho é avaliar a osseointegração e resistência mecânica de amostras de titânio grau II nitretadas, através da configuração de descarga em cátodo oco. Além disto, propor formulações para determinação da topologia ótima estrutural do implante dentário em estudo, com o intuito de aperfeiçoar sua forma, que seja eficiente, competitiva e com alta definição. No processo de nitretação, as amostras foram tratadas em temperatura a de 450 oC e pressão de 150 Pa , durante 1 hora de tratamento. Esta condição foi escolhida por apresentar os melhores resultados de molhabilidade em trabalhos anteriores, onde sistematizou-se diferentes condições de pressão, temperatura e tempo. As amostras tratadas foram caracterizadas por Difração de Raios-X, Microscopia Eletrônica de Varredura, Rugosidade, Microdureza e Molhabilidade. Posteriormente, foram realizados ensaios biomecânicos de fadiga. Finalizando com uma proposta de formulação através do método de otimização topológica tridimensional, combinado a um processo de refino h-adaptativo. Os resultados mostraram que a nitretação a plasma, utilizando a técnica de descarga em cátodo oco, produziu mudanças na textura superficial dos corpos de prova, aumento da rugosidade superficial, da molhabilidade e da microdureza quando comparado a amostra sem tratamento. No ensaio biomecânico de fadiga, o implante tratado não apresentou sinal de falha, após cinco milhões de ciclos, a uma carga máxima de fadiga de 84, 46 N . Os resultados do processo de otimização topológica apresentaram leiautes otimizados bem definidos do implante dentário, com uma nítida distribuição de material e definição do contorno.application/pdfporUniversidade Federal do Rio Grande do NortePrograma de Pós-Graduação em Engenharia MecânicaUFRNBRTecnologia de Materiais; Projetos Mecânicos; TermociênciasBiomecânica. Fadiga. Implantes Dentários. Nitretação em Plasma. Nitretação em Cátodo Oco. Otimização Topológica. OsseointegraçãoPlasma nitriding. Hollow Cathode Nitriding. Biomechanics. Fatigue. Topological Optimization. Dental Implants. OsseointegrationCNPQ::ENGENHARIAS::ENGENHARIA MECANICABiomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo ocoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNORIGINALKarilanyDC_TESE.pdfapplication/pdf5082673https://repositorio.ufrn.br/bitstream/123456789/15608/1/KarilanyDC_TESE.pdf4427463c2d2c4ca61196bdca31ba604eMD51TEXTKarilanyDC_TESE.pdf.txtKarilanyDC_TESE.pdf.txtExtracted texttext/plain289445https://repositorio.ufrn.br/bitstream/123456789/15608/6/KarilanyDC_TESE.pdf.txt743677b485e76f9221d0215eac62f5dbMD56THUMBNAILKarilanyDC_TESE.pdf.jpgKarilanyDC_TESE.pdf.jpgIM Thumbnailimage/jpeg2639https://repositorio.ufrn.br/bitstream/123456789/15608/7/KarilanyDC_TESE.pdf.jpg4da819ec7b0eb2cbb964ecb1b6dc9fd7MD57123456789/156082017-11-01 18:30:06.784oai:https://repositorio.ufrn.br:123456789/15608Repositório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2017-11-01T21:30:06Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false
dc.title.por.fl_str_mv Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
title Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
spellingShingle Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
Coutinho, Karilany Dantas
Biomecânica. Fadiga. Implantes Dentários. Nitretação em Plasma. Nitretação em Cátodo Oco. Otimização Topológica. Osseointegração
Plasma nitriding. Hollow Cathode Nitriding. Biomechanics. Fatigue. Topological Optimization. Dental Implants. Osseointegration
CNPQ::ENGENHARIAS::ENGENHARIA MECANICA
title_short Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
title_full Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
title_fullStr Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
title_full_unstemmed Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
title_sort Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco
author Coutinho, Karilany Dantas
author_facet Coutinho, Karilany Dantas
author_role author
dc.contributor.authorID.por.fl_str_mv
dc.contributor.authorLattes.por.fl_str_mv http://lattes.cnpq.br/8409211766785367
dc.contributor.advisorID.por.fl_str_mv
dc.contributor.advisorLattes.por.fl_str_mv http://lattes.cnpq.br/5028446242533356
dc.contributor.advisor-co1ID.por.fl_str_mv
dc.contributor.referees1.pt_BR.fl_str_mv Freire Júnior, Raimundo Carlos Silvério
dc.contributor.referees1ID.por.fl_str_mv
dc.contributor.referees1Lattes.por.fl_str_mv http://lattes.cnpq.br/1042806990155996
dc.contributor.referees2.pt_BR.fl_str_mv Wanderley, Caroline Dantas Vilar
dc.contributor.referees2ID.por.fl_str_mv
dc.contributor.referees2Lattes.por.fl_str_mv http://lattes.cnpq.br/7861700022912054
dc.contributor.referees3.pt_BR.fl_str_mv Costa, Thércio Henrique de Carvalho
dc.contributor.referees3ID.por.fl_str_mv
dc.contributor.referees3Lattes.por.fl_str_mv http://lattes.cnpq.br/3647710047561421
dc.contributor.author.fl_str_mv Coutinho, Karilany Dantas
dc.contributor.advisor-co1.fl_str_mv Guerra Neto, Custódio Leopoldino Brito
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/5387010100082241
dc.contributor.advisor1.fl_str_mv Costa Júnior, João Carlos Arantes
contributor_str_mv Guerra Neto, Custódio Leopoldino Brito
Costa Júnior, João Carlos Arantes
dc.subject.por.fl_str_mv Biomecânica. Fadiga. Implantes Dentários. Nitretação em Plasma. Nitretação em Cátodo Oco. Otimização Topológica. Osseointegração
topic Biomecânica. Fadiga. Implantes Dentários. Nitretação em Plasma. Nitretação em Cátodo Oco. Otimização Topológica. Osseointegração
Plasma nitriding. Hollow Cathode Nitriding. Biomechanics. Fatigue. Topological Optimization. Dental Implants. Osseointegration
CNPQ::ENGENHARIAS::ENGENHARIA MECANICA
dc.subject.eng.fl_str_mv Plasma nitriding. Hollow Cathode Nitriding. Biomechanics. Fatigue. Topological Optimization. Dental Implants. Osseointegration
dc.subject.cnpq.fl_str_mv CNPQ::ENGENHARIAS::ENGENHARIA MECANICA
description In recent years there has been a significant growth in technologies that modify implant surfaces, reducing healing time and allowing their successful use in areas with low bone density. One of the most widely used techniques is plasma nitration, applied with excellent results in titanium and its alloys, with greater frequency in the manufacture of hip, ankle and shoulder implants. However, its use in dental implants is very limited due to high process temperatures (between 700 C o and 800 C o ), resulting in distortions in these geometrically complex and highly precise components. The aim of the present study is to assess osseointegration and mechanical strength of grade II nitrided titanium samples, through configuration of hollow cathode discharge. Moreover, new formulations are proposed to determine the optimum structural topology of the dental implant under study, in order to perfect its shape, make it efficient, competitive and with high definition. In the nitriding process, the samples were treated at a temperature of 450 C o and pressure of 150 Pa , during 1 hour of treatment. This condition was selected because it obtains the best wettability results in previous studies, where different pressure, temperature and time conditions were systematized. The samples were characterized by X-ray diffraction, scanning electron microscope, roughness, microhardness and wettability. Biomechanical fatigue tests were then conducted. Finally, a formulation using the three dimensional structural topology optimization method was proposed, in conjunction with an hadaptive refinement process. The results showed that plasma nitriding, using the hollow cathode discharge technique, caused changes in the surface texture of test specimens, increases surface roughness, wettability and microhardness when compared to the untreated sample. In the biomechanical fatigue test, the treated implant showed no flaws, after five million cycles, at a maximum fatigue load of 84.46 N. The results of the topological optimization process showed well-defined optimized layouts of the dental implant, with a clear distribution of material and a defined edge
publishDate 2014
dc.date.accessioned.fl_str_mv 2014-12-17T14:57:58Z
dc.date.available.fl_str_mv 2014-10-23
2014-12-17T14:57:58Z
dc.date.issued.fl_str_mv 2014-06-10
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv COUTINHO, Karilany Dantas. Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco. 2014. 225 f. Tese (Doutorado em Tecnologia de Materiais; Projetos Mecânicos; Termociências) - Universidade Federal do Rio Grande do Norte, Natal, 2014.
dc.identifier.uri.fl_str_mv https://repositorio.ufrn.br/jspui/handle/123456789/15608
identifier_str_mv COUTINHO, Karilany Dantas. Biomecânica e otimização topológica com H-adaptatividade em implantes dentários nitretados a plasma em cátodo oco. 2014. 225 f. Tese (Doutorado em Tecnologia de Materiais; Projetos Mecânicos; Termociências) - Universidade Federal do Rio Grande do Norte, Natal, 2014.
url https://repositorio.ufrn.br/jspui/handle/123456789/15608
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Engenharia Mecânica
dc.publisher.initials.fl_str_mv UFRN
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Tecnologia de Materiais; Projetos Mecânicos; Termociências
publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRN
instname:Universidade Federal do Rio Grande do Norte (UFRN)
instacron:UFRN
instname_str Universidade Federal do Rio Grande do Norte (UFRN)
instacron_str UFRN
institution UFRN
reponame_str Repositório Institucional da UFRN
collection Repositório Institucional da UFRN
bitstream.url.fl_str_mv https://repositorio.ufrn.br/bitstream/123456789/15608/1/KarilanyDC_TESE.pdf
https://repositorio.ufrn.br/bitstream/123456789/15608/6/KarilanyDC_TESE.pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/15608/7/KarilanyDC_TESE.pdf.jpg
bitstream.checksum.fl_str_mv 4427463c2d2c4ca61196bdca31ba604e
743677b485e76f9221d0215eac62f5db
4da819ec7b0eb2cbb964ecb1b6dc9fd7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)
repository.mail.fl_str_mv
_version_ 1802117672984379392