Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte

Detalhes bibliográficos
Autor(a) principal: Cechinel, André Luiz Prado
Data de Publicação: 2019
Tipo de documento: Trabalho de conclusão de curso
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/handle/123456789/193282
Resumo: TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Elétrica.
id UFSC_9c6f2381ec77014af69f98e8e2fe7989
oai_identifier_str oai:repositorio.ufsc.br:123456789/193282
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porteEnergia Solar FotovoltaicaTaxa de DesempenhoÍndice de Desempenho EnergéticoCertificaçãoTCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Elétrica.A certificação e o monitoramento de Usinas Fotovoltaicas (FV) de grande porte são etapas fundamentais para o controle de desempenho e para a saúde financeira deste tipo de empreendimento. No presente trabalho, são avaliadas duas diferentes metodologias de análise de desempenho de sistemas FV, estabelecidas em normativas internacionais: a Taxa de Desempenho (PR) e o Índice de Desempenho Energético (IDE). A análise será empregada no estudo de caso de um sistema fotovoltaico de 36 MWp com sistema de rastreamento de um eixo, instalada no município de Assu – RN, durante um período de dois meses. Utilizando as duas metodologias na análise de desempenho, é possível obter insumos a respeito da aplicabilidade de cada metodologia em grandes usinas, nos contextos de certificação e de monitoramento. O cálculo das figuras de mérito associadas a cada metodologia se dá através de criteriosa análise de dados de energia e irradiação. A análise da usina é realizada através de dados de potência gerada na saída do inversor, permitindo analisar individualmente o desempenho de inversores. Esta análise individual também é feita para nove inversores de mesma potência instalada em três diferentes áreas da usina. Os dados medidos são comparados com dados obtidos no processo de certificação da usina, os quais são obtidos através de bancos de dados históricos aplicados ao software de simulação PVsyst. Através da análise, constata-se que o modelo de simulação e o banco de dados utilizado subestimam as perdas reais do sistema, tendo em vista que os valores medidos de energia são até 5% menores que os valores esperados. Os resultados medidos de PR também são sistematicamente inferiores aos valores esperados, embora mais próximos que os resultados de IDE – 3 e 5%, respectivamente. O resultado de PR previsto para o período é de 85%, enquanto o resultado de PR medido é de 79%, essa diferença se deve às perdas consideradas no modelo de simulação. Os valores medidos de irradiação foram consideravelmente maiores que os valores previstos, com uma diferença total de 50 kWh/m² (15%) para o período analisado. Os resultados corroboram com o uso do IDE para a certificação de grandes usinas, embora análises mais completas sejam necessárias para a obtenção de conclusões mais sólidas.The certification and monitoring of large scale Photovoltaic (PV) Plants are essential steps in controlling the performance and financial health of this type of project. In the present paper, two different performance methodologies of PV systems established in international norms are evaluated: the Performance Ratio (PR) and the Energy Performance Index (IDE). The analysis will be employed in the case study of a 36 MWp photovoltaic system with a single axis tracking system, installed in the city of Assu - RN, over a period of two months. By using the two methodologies in the performance analysis, it is possible to obtain insights regarding the applicability of each methodology in large plants, in both certification and monitoring contexts. The calculation of the figures of merit associated to each methodology is given through careful analysis of energy and irradiation data. The analysis of the power plant is performed through the power data generated at the output of the inverter, allowing the individual performance of inverters to be evaluated. This individual analysis is also done for nine inverters with the same installed power in three different areas of the plant. The measured data is compared to data obtained in the plant certification process, which is obtained through historical databases applied to the PVsyst simulation software. Through the analysis, it is verified that the simulation model and the selected database underestimates the actual losses of the system, considering that the measured values of energy are up to 5% lower than the expected values. The measured results of PR are also systematically lower than the expected values, although closer than the results of IDE - 3 and 5%, respectively. The expected PR result for the period is 85%, while the measured PR result is 79%, this difference is due to the losses considered in the simulation model. Measured irradiation values were considerably higher than the predicted values, with a total difference of 50 kWh / m² (15%) for the analyzed period. The results corroborate with the use of IDE for the certification of large plants, although more complete analyzes are necessary to obtain more solid conclusions.Florianópolis, SCNascimento, Lucas Rafael doRüther, RicardoUniversidade Federal de Santa CatarinaCechinel, André Luiz Prado2019-02-11T19:08:55Z2019-02-11T19:08:55Z2019-02-05info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis100application/pdfhttps://repositorio.ufsc.br/handle/123456789/193282porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2019-02-11T19:08:56Zoai:repositorio.ufsc.br:123456789/193282Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732019-02-11T19:08:56Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
title Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
spellingShingle Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
Cechinel, André Luiz Prado
Energia Solar Fotovoltaica
Taxa de Desempenho
Índice de Desempenho Energético
Certificação
title_short Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
title_full Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
title_fullStr Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
title_full_unstemmed Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
title_sort Comparação de metodologias de análise de desempenho para usinas fotovoltaicas de grande porte
author Cechinel, André Luiz Prado
author_facet Cechinel, André Luiz Prado
author_role author
dc.contributor.none.fl_str_mv Nascimento, Lucas Rafael do
Rüther, Ricardo
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Cechinel, André Luiz Prado
dc.subject.por.fl_str_mv Energia Solar Fotovoltaica
Taxa de Desempenho
Índice de Desempenho Energético
Certificação
topic Energia Solar Fotovoltaica
Taxa de Desempenho
Índice de Desempenho Energético
Certificação
description TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Elétrica.
publishDate 2019
dc.date.none.fl_str_mv 2019-02-11T19:08:55Z
2019-02-11T19:08:55Z
2019-02-05
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufsc.br/handle/123456789/193282
url https://repositorio.ufsc.br/handle/123456789/193282
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 100
application/pdf
dc.publisher.none.fl_str_mv Florianópolis, SC
publisher.none.fl_str_mv Florianópolis, SC
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1808652338873761792