Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico

Detalhes bibliográficos
Autor(a) principal: Knorr, Camila de Lellis
Data de Publicação: 2014
Tipo de documento: Tese
Idioma: por
Título da fonte: Manancial - Repositório Digital da UFSM
Texto Completo: http://repositorio.ufsm.br/handle/1/11988
Resumo: In this work, sample preparation methods were proposed, microwave-induced combustion (MIC) and microwave-assisted wet digestion (MAWD), for further Br, Cl, Cr, Cu, I and Mn determination in pharmaceutical capsules. For Cl, Br and I determination, ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) were used. The ICP-MS technique was also used for Cr, Cu and Mn determination, as well as graphite furnace atomic absorption spectrometry (GF AAS) and by solid sampling graphite furnace atomic absorption spectrometry (SS GF AAS). For MAWD digestion, it was possible to digest 300 mg samples, whereas in MIC up to 500 mg of sample were used. Also, MIC digestion allowed the digestion using diluted nitric acid for all elements, except for Br and I which require diluted alkaline solution. The carbon content was determined in samples after decomposition in order to evaluate the efficiency of decomposition. Sample decomposition was complete for all sample preparation methods applied, since the carbon content in MAWD solutions was 60 mg L-1 and it was lower than the limit of detection (10 mg L-1) for MIC solutions. Certified reference material of whole milk powder was used to evaluate the accuracy of MIC digestion and the agreement to certified values was between 94 and 102%. In conclusion, the investigated sample preparation methods were suitable to pharmaceutical capsules digestion as well as for the determination techniques. Also, chlorine recovery was possible with diluted acid solutions in MIC digestion.
id UFSM_0e0b0720fc5bf51e55639eda3aaef1a5
oai_identifier_str oai:repositorio.ufsm.br:1/11988
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêuticoQuímica analíticaCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICAIn this work, sample preparation methods were proposed, microwave-induced combustion (MIC) and microwave-assisted wet digestion (MAWD), for further Br, Cl, Cr, Cu, I and Mn determination in pharmaceutical capsules. For Cl, Br and I determination, ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) were used. The ICP-MS technique was also used for Cr, Cu and Mn determination, as well as graphite furnace atomic absorption spectrometry (GF AAS) and by solid sampling graphite furnace atomic absorption spectrometry (SS GF AAS). For MAWD digestion, it was possible to digest 300 mg samples, whereas in MIC up to 500 mg of sample were used. Also, MIC digestion allowed the digestion using diluted nitric acid for all elements, except for Br and I which require diluted alkaline solution. The carbon content was determined in samples after decomposition in order to evaluate the efficiency of decomposition. Sample decomposition was complete for all sample preparation methods applied, since the carbon content in MAWD solutions was 60 mg L-1 and it was lower than the limit of detection (10 mg L-1) for MIC solutions. Certified reference material of whole milk powder was used to evaluate the accuracy of MIC digestion and the agreement to certified values was between 94 and 102%. In conclusion, the investigated sample preparation methods were suitable to pharmaceutical capsules digestion as well as for the determination techniques. Also, chlorine recovery was possible with diluted acid solutions in MIC digestion.Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqNeste trabalho foram avaliados dois métodos de preparo de amostra, combustão iniciada por micro-ondas (MIC) e decomposição via úmida assistida por radiação micro-ondas (MAWD), para a posterior determinação de Br, Cl, Cr, Cu, I e Mn em cápsulas de uso farmacêutico. A determinação de Cl, Br e I foi feita por espectrometria de massa com plasma indutivamente acoplado (ICP-MS) e por cromatografia de íons (IC). Por outro lado, a determinação de Cr, Cu e Mn foi feita por ICP-MS, por espectrometria de absorção atômica com forno de grafite (GF AAS) e por análise por amostragem direta de sólidos acoplada a GF AAS (SS GF AAS). A decomposição por MAWD possibilitou o uso de 300 mg de amostra, enquanto que, para MIC, foi possível decompor até 500 mg de amostra. Foi possível a utilização de HNO3 diluído para a absorção dos analitos, exceto para Br e I onde foi necessário o uso de soluções alcalinas diluídas. Para a determinação de Cl foi possível a utilização de HNO3 diluído como solução absorvedora durante a MIC, assim como soluções alcalinas diluídas. A eficiência dos métodos de decomposição foi avaliada através da determinação de carbono residual nas soluções obtidas após MIC e MAWD. Foi observado que o valor de carbono residual nas soluções obtidas após MAWD foi de, aproximadamente, 60 mg L-1 e, nas soluções após MIC, foi inferior ao limite de detecção (10 mg L-1), o que demonstra a boa eficiência de decomposição das amostras por ambos os métodos utilizados. A exatidão do método empregando MIC foi avaliada através da análise de material de referência certificado (CRM) de leite em pó. As concordâncias obtidas para todos os elementos foram entre 94 e 102%. Pode-se concluir que os métodos de preparo de amostra avaliados foram adequados à decomposição das amostras, assim como às técnicas utilizadas para a determinação dos analitos. Cabe destacar, também, que foi possível a recuperação de Cl nas amostras e no CRM utilizando ácido diluído como solução absorvedora durante as decomposições por MIC.Universidade Federal de Santa MariaBrasilQuímicaUFSMPrograma de Pós-Graduação em QuímicaCentro de Ciências Naturais e ExatasFlores, Érico Marlon de Moraeshttp://lattes.cnpq.br/7167629055579212Costa, Adilson Ben dahttp://lattes.cnpq.br/2604778196819181Mello, Paola de Azevedohttp://lattes.cnpq.br/2189500441942469Dressler, Valderi Luizhttp://lattes.cnpq.br/4054740296547580Mortari, Sergio Robertohttp://lattes.cnpq.br/7784609477475171Knorr, Camila de Lellis2017-11-08T12:35:23Z2017-11-08T12:35:23Z2014info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfhttp://repositorio.ufsm.br/handle/1/11988porAttribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2017-12-02T15:34:48Zoai:repositorio.ufsm.br:1/11988Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2017-12-02T15:34:48Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
title Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
spellingShingle Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
Knorr, Camila de Lellis
Química analítica
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
title_full Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
title_fullStr Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
title_full_unstemmed Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
title_sort Avaliação de métodos de preparo de amostras para posterior determinação de contaminantes inorgânicos em cápsulas de uso farmacêutico
author Knorr, Camila de Lellis
author_facet Knorr, Camila de Lellis
author_role author
dc.contributor.none.fl_str_mv Flores, Érico Marlon de Moraes
http://lattes.cnpq.br/7167629055579212
Costa, Adilson Ben da
http://lattes.cnpq.br/2604778196819181
Mello, Paola de Azevedo
http://lattes.cnpq.br/2189500441942469
Dressler, Valderi Luiz
http://lattes.cnpq.br/4054740296547580
Mortari, Sergio Roberto
http://lattes.cnpq.br/7784609477475171
dc.contributor.author.fl_str_mv Knorr, Camila de Lellis
dc.subject.por.fl_str_mv Química analítica
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
topic Química analítica
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description In this work, sample preparation methods were proposed, microwave-induced combustion (MIC) and microwave-assisted wet digestion (MAWD), for further Br, Cl, Cr, Cu, I and Mn determination in pharmaceutical capsules. For Cl, Br and I determination, ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) were used. The ICP-MS technique was also used for Cr, Cu and Mn determination, as well as graphite furnace atomic absorption spectrometry (GF AAS) and by solid sampling graphite furnace atomic absorption spectrometry (SS GF AAS). For MAWD digestion, it was possible to digest 300 mg samples, whereas in MIC up to 500 mg of sample were used. Also, MIC digestion allowed the digestion using diluted nitric acid for all elements, except for Br and I which require diluted alkaline solution. The carbon content was determined in samples after decomposition in order to evaluate the efficiency of decomposition. Sample decomposition was complete for all sample preparation methods applied, since the carbon content in MAWD solutions was 60 mg L-1 and it was lower than the limit of detection (10 mg L-1) for MIC solutions. Certified reference material of whole milk powder was used to evaluate the accuracy of MIC digestion and the agreement to certified values was between 94 and 102%. In conclusion, the investigated sample preparation methods were suitable to pharmaceutical capsules digestion as well as for the determination techniques. Also, chlorine recovery was possible with diluted acid solutions in MIC digestion.
publishDate 2014
dc.date.none.fl_str_mv 2014
2017-11-08T12:35:23Z
2017-11-08T12:35:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/11988
url http://repositorio.ufsm.br/handle/1/11988
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
Brasil
Química
UFSM
Programa de Pós-Graduação em Química
Centro de Ciências Naturais e Exatas
publisher.none.fl_str_mv Universidade Federal de Santa Maria
Brasil
Química
UFSM
Programa de Pós-Graduação em Química
Centro de Ciências Naturais e Exatas
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1805922143279513600