Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Science |
Texto Completo: | https://ojs.ict.unesp.br/index.php/cob/article/view/993 |
Resumo: | Objective: This clinical study evaluated the success of two different splint materials bonded on periodontally treated mobile teeth.Methods: A total of 14 patients were included in the study. Patients were randomly assigned to the groups to receive either with or wire composite splint (WCS) or fiber-reinforced composite splint (FCS). Clinical periodontal parameters were performed and periotest values were recorded at baseline, and after 6 and 12 months. Patients were asked to complete a self-administered questionnaire after the splinting procedures. Failure types for the splints were categorized.Results: Baseline PI values showed significant decrease at 6 month follow up in the WCS (p=0.0019) and FCS (p<0.0001) groups and remained stable after 12 months (WCS; p=0.36, FCS; p=0.63). During the course of the study, PD and RD values exhibited no change between and within groups. Clinical parameters including PD, RD, PI and BOP were stable at 6 and 12 months follow-up period. In 6 patients (4 FCS, 2 WCS), reparable failures occurred during the observation period. In four patients (3 FCS, 1 WCS) splints failed completely and were removed. The periotest values of the failing teeth ranged between 47.3 and 50. In 3 patients in the WCS and 1 patient in the FCS group, periotest values were ? 40 but no splint failures were observed.Conclusion: FCS tends to show increased mechanical limitations compared to WCS. Teeth with periotest values above 40 may be more prone to splint failures independent of the splint material. |
id |
UNESP-20_d62a539289fb143817c54ab7b547171c |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/993 |
network_acronym_str |
UNESP-20 |
network_name_str |
Brazilian Dental Science |
repository_id_str |
|
spelling |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teethObjective: This clinical study evaluated the success of two different splint materials bonded on periodontally treated mobile teeth.Methods: A total of 14 patients were included in the study. Patients were randomly assigned to the groups to receive either with or wire composite splint (WCS) or fiber-reinforced composite splint (FCS). Clinical periodontal parameters were performed and periotest values were recorded at baseline, and after 6 and 12 months. Patients were asked to complete a self-administered questionnaire after the splinting procedures. Failure types for the splints were categorized.Results: Baseline PI values showed significant decrease at 6 month follow up in the WCS (p=0.0019) and FCS (p<0.0001) groups and remained stable after 12 months (WCS; p=0.36, FCS; p=0.63). During the course of the study, PD and RD values exhibited no change between and within groups. Clinical parameters including PD, RD, PI and BOP were stable at 6 and 12 months follow-up period. In 6 patients (4 FCS, 2 WCS), reparable failures occurred during the observation period. In four patients (3 FCS, 1 WCS) splints failed completely and were removed. The periotest values of the failing teeth ranged between 47.3 and 50. In 3 patients in the WCS and 1 patient in the FCS group, periotest values were ? 40 but no splint failures were observed.Conclusion: FCS tends to show increased mechanical limitations compared to WCS. Teeth with periotest values above 40 may be more prone to splint failures independent of the splint material. Institute of Science and Technology of São José dos Campos2014-08-25info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/mswordapplication/mswordapplication/mswordapplication/mswordapplication/mswordapplication/pdfapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/99310.14295/bds.2014.v17i3.993Brazilian Dental Science; Vol. 17 No. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 39-49Brazilian Dental Science; v. 17 n. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 39-492178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/993/879https://ojs.ict.unesp.br/index.php/cob/article/view/993/2068https://ojs.ict.unesp.br/index.php/cob/article/view/993/2069https://ojs.ict.unesp.br/index.php/cob/article/view/993/2070https://ojs.ict.unesp.br/index.php/cob/article/view/993/2071https://ojs.ict.unesp.br/index.php/cob/article/view/993/2072https://ojs.ict.unesp.br/index.php/cob/article/view/993/2073https://ojs.ict.unesp.br/index.php/cob/article/view/993/2074Akcalı, AliyeGümüş, PınarÖzcan, Mutluinfo:eu-repo/semantics/openAccess2020-01-28T12:31:07Zoai:ojs.pkp.sfu.ca:article/993Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:29:57.151811Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true |
dc.title.none.fl_str_mv |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth |
title |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth |
spellingShingle |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth Akcalı, Aliye |
title_short |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth |
title_full |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth |
title_fullStr |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth |
title_full_unstemmed |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth |
title_sort |
Clinical comparison of fiber-reinforced composite and stainless steel wire for splinting periodontally treated mobile teeth |
author |
Akcalı, Aliye |
author_facet |
Akcalı, Aliye Gümüş, Pınar Özcan, Mutlu |
author_role |
author |
author2 |
Gümüş, Pınar Özcan, Mutlu |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Akcalı, Aliye Gümüş, Pınar Özcan, Mutlu |
description |
Objective: This clinical study evaluated the success of two different splint materials bonded on periodontally treated mobile teeth.Methods: A total of 14 patients were included in the study. Patients were randomly assigned to the groups to receive either with or wire composite splint (WCS) or fiber-reinforced composite splint (FCS). Clinical periodontal parameters were performed and periotest values were recorded at baseline, and after 6 and 12 months. Patients were asked to complete a self-administered questionnaire after the splinting procedures. Failure types for the splints were categorized.Results: Baseline PI values showed significant decrease at 6 month follow up in the WCS (p=0.0019) and FCS (p<0.0001) groups and remained stable after 12 months (WCS; p=0.36, FCS; p=0.63). During the course of the study, PD and RD values exhibited no change between and within groups. Clinical parameters including PD, RD, PI and BOP were stable at 6 and 12 months follow-up period. In 6 patients (4 FCS, 2 WCS), reparable failures occurred during the observation period. In four patients (3 FCS, 1 WCS) splints failed completely and were removed. The periotest values of the failing teeth ranged between 47.3 and 50. In 3 patients in the WCS and 1 patient in the FCS group, periotest values were ? 40 but no splint failures were observed.Conclusion: FCS tends to show increased mechanical limitations compared to WCS. Teeth with periotest values above 40 may be more prone to splint failures independent of the splint material. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-08-25 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/993 10.14295/bds.2014.v17i3.993 |
url |
https://ojs.ict.unesp.br/index.php/cob/article/view/993 |
identifier_str_mv |
10.14295/bds.2014.v17i3.993 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/993/879 https://ojs.ict.unesp.br/index.php/cob/article/view/993/2068 https://ojs.ict.unesp.br/index.php/cob/article/view/993/2069 https://ojs.ict.unesp.br/index.php/cob/article/view/993/2070 https://ojs.ict.unesp.br/index.php/cob/article/view/993/2071 https://ojs.ict.unesp.br/index.php/cob/article/view/993/2072 https://ojs.ict.unesp.br/index.php/cob/article/view/993/2073 https://ojs.ict.unesp.br/index.php/cob/article/view/993/2074 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/msword application/msword application/msword application/msword application/msword application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
dc.source.none.fl_str_mv |
Brazilian Dental Science; Vol. 17 No. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 39-49 Brazilian Dental Science; v. 17 n. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 39-49 2178-6011 reponame:Brazilian Dental Science instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Brazilian Dental Science |
collection |
Brazilian Dental Science |
repository.name.fl_str_mv |
Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
repository.mail.fl_str_mv |
sergio@fosjc.unesp.br||sergio@fosjc.unesp.br |
_version_ |
1788346898965331968 |