Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units

Detalhes bibliográficos
Autor(a) principal: Schwab , Juliana Barbosa
Data de Publicação: 2020
Outros Autores: M¨¨¨¨¨¨uller , Erildo Vicente, Mendes, Elisa Donalisio Teixeira, Borges , Pollyanna Kássia de Oliveira, Ivastcheschen, Taís
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/11048
Resumo: This study aimed to evaluate the impact of invasive devices as risk factors for the development of neonatal sepsis in Neonatal Intensive Care Units. Hospital-based retrospective cohort study performed in two Neonatal Intensive Care Units in Ponta Grossa, Paraná, Brazil. Documentary data were collected through consultation of electronic medical charts of all patients admitted to two hospitals and of the patients with diagnosis of sepsis in another hospital. Health conditions at admission and outcomes were evaluated. Frequencies of the reasons for admission and the outcomes were calculated. In the association analysis, exposure variables were calculated with odds ratio and confidence intervals (95%). The frequency of sepsis was 39%, and 45.7% of the cases were of early-onset sepsis and 54.3% of late-onset sepsis. The mortality rate associated with sepsis was 9.9%. The use of invasive devices was observed to increase by 6 times the risk of neonatal sepsis. Peripherally inserted central catheter and phlebotomy were the devices causing higher risk. The high incidence of late-onset sepsis, its association with the use of invasive devices and the higher mortality rate among newborns with sepsis suggest the presence of fragilities in neonatal care and the need to seek alternatives of neonatal approach to avoid new cases of neonatal sepsis and consequent death.
id UNIFEI_523d2622e4c94c72ed5fb351cd71d315
oai_identifier_str oai:ojs.pkp.sfu.ca:article/11048
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Invasive devices as risk factors for neonatal sepsis in neonatal intensive care unitsDispositivos invasivos como factores de riesgo de sepsis neonatal en unidades de cuidados intensivos neonatalesDispositivos invasivos como fatores de risco para sepse neonatal em unidades de terapia intensiva neonatalSepseComplicações Infecciosas na GravidezServiços de saúde da criança.SepsisComplicaciones Infecciosas del EmbarazoServicios de salud del niño.SepsisPregnancy Complications, InfectiousChild health services.This study aimed to evaluate the impact of invasive devices as risk factors for the development of neonatal sepsis in Neonatal Intensive Care Units. Hospital-based retrospective cohort study performed in two Neonatal Intensive Care Units in Ponta Grossa, Paraná, Brazil. Documentary data were collected through consultation of electronic medical charts of all patients admitted to two hospitals and of the patients with diagnosis of sepsis in another hospital. Health conditions at admission and outcomes were evaluated. Frequencies of the reasons for admission and the outcomes were calculated. In the association analysis, exposure variables were calculated with odds ratio and confidence intervals (95%). The frequency of sepsis was 39%, and 45.7% of the cases were of early-onset sepsis and 54.3% of late-onset sepsis. The mortality rate associated with sepsis was 9.9%. The use of invasive devices was observed to increase by 6 times the risk of neonatal sepsis. Peripherally inserted central catheter and phlebotomy were the devices causing higher risk. The high incidence of late-onset sepsis, its association with the use of invasive devices and the higher mortality rate among newborns with sepsis suggest the presence of fragilities in neonatal care and the need to seek alternatives of neonatal approach to avoid new cases of neonatal sepsis and consequent death.Incluir o resumo em espanhol. Este estudio tuvo como objetivo evaluar el impacto de los dispositivos invasivos como factores de riesgo para el desarrollo de sepsis neonatal en Unidades de Cuidados Intensivos Neonatales. Estudio de cohorte retrospectivo de base hospitalaria realizado en dos Unidades de Cuidados Intensivos Neonatales en Ponta Grossa, Paraná, Brasil. Los datos documentales se recogieron mediante consulta de historias clínicas electrónicas de todos los pacientes ingresados ​​en dos hospitales y de los pacientes con diagnóstico de sepsis en otro hospital. Se evaluaron las condiciones de salud al ingreso y los resultados. Se calcularon las frecuencias de los motivos de ingreso y los resultados. En el análisis de asociación, las variables de exposición se calcularon con razón de probabilidades e intervalos de confianza (95%). La frecuencia de sepsis fue del 39% y el 45,7% de los casos fueron de sepsis de inicio temprano y el 54,3% de sepsis de inicio tardío. La tasa de mortalidad asociada a la sepsis fue del 9,9%. Se observó que el uso de dispositivos invasivos aumentaba en 6 veces el riesgo de sepsis neonatal. El catéter central de inserción periférica y la flebotomía fueron los dispositivos de mayor riesgo. La alta incidencia de sepsis de inicio tardío, su asociación con el uso de dispositivos invasivos y la mayor tasa de mortalidad entre los recién nacidos con sepsis sugieren la presencia de fragilidades en la atención neonatal y la necesidad de buscar alternativas de abordaje neonatal para evitar nuevos casos de sepsis neonatal y consecuente muerte.Incluir o resumo. Este estudo teve como objetivo avaliar o impacto dos dispositivos invasivos como fatores de risco para o desenvolvimento de sepse neonatal em Unidades de Terapia Intensiva Neonatal. Estudo de coorte retrospectivo de base hospitalar realizado em duas Unidades de Terapia Intensiva Neonatal de Ponta Grossa, Paraná, Brasil. Os dados documentais foram coletados por meio de consulta a prontuários eletrônicos de todos os pacientes internados em dois hospitais e dos pacientes com diagnóstico de sepse em outro hospital. As condições de saúde na admissão e os resultados foram avaliados. Foram calculadas as frequências dos motivos de admissão e os desfechos. Na análise de associação, as variáveis ​​de exposição foram calculadas com odds ratio e intervalos de confiança (95%). A frequência de sepse foi de 39%, sendo 45,7% dos casos de sepse precoce e 54,3% de sepse tardia. A mortalidade associada à sepse foi de 9,9%. Observou-se que o uso de dispositivos invasivos aumenta em 6 vezes o risco de sepse neonatal. Cateter central de inserção periférica e flebotomia foram os dispositivos de maior risco. A alta incidência de sepse tardia, sua associação com o uso de dispositivos invasivos e a maior mortalidade entre os recém-nascidos com sepse sugerem a presença de fragilidades na assistência neonatal e a necessidade de buscar alternativas de abordagem neonatal para evitar novos casos de sepse neonatal e consequente morte.Research, Society and Development2020-12-24info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1104810.33448/rsd-v9i12.11048Research, Society and Development; Vol. 9 No. 12; e27891211048Research, Society and Development; Vol. 9 Núm. 12; e27891211048Research, Society and Development; v. 9 n. 12; e278912110482525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/11048/9923Copyright (c) 2020 Juliana Barbosa Schwab ; Erildo Vicente M¨¨¨¨¨¨uller ; Elisa Donalisio Teixeira Mendes; Pollyanna Kássia de Oliveira Borges ; Taís Ivastcheschenhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessSchwab , Juliana BarbosaM¨¨¨¨¨¨uller , Erildo VicenteMendes, Elisa Donalisio Teixeira Borges , Pollyanna Kássia de OliveiraIvastcheschen, Taís2020-12-30T23:32:22Zoai:ojs.pkp.sfu.ca:article/11048Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:32:58.603960Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
Dispositivos invasivos como factores de riesgo de sepsis neonatal en unidades de cuidados intensivos neonatales
Dispositivos invasivos como fatores de risco para sepse neonatal em unidades de terapia intensiva neonatal
title Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
spellingShingle Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
Schwab , Juliana Barbosa
Sepse
Complicações Infecciosas na Gravidez
Serviços de saúde da criança.
Sepsis
Complicaciones Infecciosas del Embarazo
Servicios de salud del niño.
Sepsis
Pregnancy Complications, Infectious
Child health services.
title_short Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
title_full Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
title_fullStr Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
title_full_unstemmed Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
title_sort Invasive devices as risk factors for neonatal sepsis in neonatal intensive care units
author Schwab , Juliana Barbosa
author_facet Schwab , Juliana Barbosa
M¨¨¨¨¨¨uller , Erildo Vicente
Mendes, Elisa Donalisio Teixeira
Borges , Pollyanna Kássia de Oliveira
Ivastcheschen, Taís
author_role author
author2 M¨¨¨¨¨¨uller , Erildo Vicente
Mendes, Elisa Donalisio Teixeira
Borges , Pollyanna Kássia de Oliveira
Ivastcheschen, Taís
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Schwab , Juliana Barbosa
M¨¨¨¨¨¨uller , Erildo Vicente
Mendes, Elisa Donalisio Teixeira
Borges , Pollyanna Kássia de Oliveira
Ivastcheschen, Taís
dc.subject.por.fl_str_mv Sepse
Complicações Infecciosas na Gravidez
Serviços de saúde da criança.
Sepsis
Complicaciones Infecciosas del Embarazo
Servicios de salud del niño.
Sepsis
Pregnancy Complications, Infectious
Child health services.
topic Sepse
Complicações Infecciosas na Gravidez
Serviços de saúde da criança.
Sepsis
Complicaciones Infecciosas del Embarazo
Servicios de salud del niño.
Sepsis
Pregnancy Complications, Infectious
Child health services.
description This study aimed to evaluate the impact of invasive devices as risk factors for the development of neonatal sepsis in Neonatal Intensive Care Units. Hospital-based retrospective cohort study performed in two Neonatal Intensive Care Units in Ponta Grossa, Paraná, Brazil. Documentary data were collected through consultation of electronic medical charts of all patients admitted to two hospitals and of the patients with diagnosis of sepsis in another hospital. Health conditions at admission and outcomes were evaluated. Frequencies of the reasons for admission and the outcomes were calculated. In the association analysis, exposure variables were calculated with odds ratio and confidence intervals (95%). The frequency of sepsis was 39%, and 45.7% of the cases were of early-onset sepsis and 54.3% of late-onset sepsis. The mortality rate associated with sepsis was 9.9%. The use of invasive devices was observed to increase by 6 times the risk of neonatal sepsis. Peripherally inserted central catheter and phlebotomy were the devices causing higher risk. The high incidence of late-onset sepsis, its association with the use of invasive devices and the higher mortality rate among newborns with sepsis suggest the presence of fragilities in neonatal care and the need to seek alternatives of neonatal approach to avoid new cases of neonatal sepsis and consequent death.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-24
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/11048
10.33448/rsd-v9i12.11048
url https://rsdjournal.org/index.php/rsd/article/view/11048
identifier_str_mv 10.33448/rsd-v9i12.11048
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/11048/9923
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 9 No. 12; e27891211048
Research, Society and Development; Vol. 9 Núm. 12; e27891211048
Research, Society and Development; v. 9 n. 12; e27891211048
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052744011350016