Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report

Detalhes bibliográficos
Autor(a) principal: Kalil, Eduardo Cekaunaskas
Data de Publicação: 2021
Outros Autores: Santos, Elaine Marcílio, Dottore, Alexandre Melloti, Sobral, Sergio de Sousa, Sobral, Ana Paula Taboada, Fernandes, Kristianne Porta Santos, Motta, Lara Jansiski, Horliana, Anna Carolina Ratto Tempestini, Gomes, Andréa Oliver, Bussadori, Sandra Kalil
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/12467
Resumo: Objective: The aim of the present study was to evaluate radiographically the remodeling of the peri-implant bone crest in prosthetic friction morse cone implants, with platform switching, after 12 months of application of prosthetic load. Materials and Methods: 16 implants were installed, in 10 patients, rehabilitated with partial, single and multiple metal-ceramic prostheses, submitted to prosthetic function in the period of 12 months. Periapical radiographs to measure the distance between the mesial and distal marginal bone crest and the platform of each implant, were performed at the time of installing the prostheses and 12 months later. The images obtained at different intervals were digitized and analyzed using Image J software TD. Results: At the time of installing the prostheses, the averages of measurements on the distal and mesial surfaces were 0.57 mm (standard deviation 0.45) and 0.55 mm (standard deviation 0.41) respectively. After 12 months in function, the averages obtained were 0.59 mm (standard deviation 0.48) on the distal surface and 0.57 mm on the mesial surface, (standard deviation 0.34). Conclusion: In this radiographic evaluation, it was possible to observe that the implants with prosthetic connection of the frictional Cone Morse type with platform switching presented an average of 0.2mm of cervical bone remodeling, after 12 months in function, seeming to be a good alternative for periodic bone maintenance deploy.
id UNIFEI_6b0ad2a1a84a6c4b9999c2e4e8341761
oai_identifier_str oai:ojs.pkp.sfu.ca:article/12467
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases reportEvaluación radiográfica prospectiva del mantenimiento óseo peri-implantario en implantes osteointegrados con conexión de cono morse por fricción y plataforma de switching: Informes de casosAvaliação radiográfica prospectiva da manutenção óssea peri-implantar nos implantes osseointegráveis com conexão cone morse friccional e plataforma switching: Relato de casosOdontologiaImplantes dentáriosOsseointegração.OdontologíaImplantes dentalesOsteointegración.DentistryDental implantsOsseointegration.Objective: The aim of the present study was to evaluate radiographically the remodeling of the peri-implant bone crest in prosthetic friction morse cone implants, with platform switching, after 12 months of application of prosthetic load. Materials and Methods: 16 implants were installed, in 10 patients, rehabilitated with partial, single and multiple metal-ceramic prostheses, submitted to prosthetic function in the period of 12 months. Periapical radiographs to measure the distance between the mesial and distal marginal bone crest and the platform of each implant, were performed at the time of installing the prostheses and 12 months later. The images obtained at different intervals were digitized and analyzed using Image J software TD. Results: At the time of installing the prostheses, the averages of measurements on the distal and mesial surfaces were 0.57 mm (standard deviation 0.45) and 0.55 mm (standard deviation 0.41) respectively. After 12 months in function, the averages obtained were 0.59 mm (standard deviation 0.48) on the distal surface and 0.57 mm on the mesial surface, (standard deviation 0.34). Conclusion: In this radiographic evaluation, it was possible to observe that the implants with prosthetic connection of the frictional Cone Morse type with platform switching presented an average of 0.2mm of cervical bone remodeling, after 12 months in function, seeming to be a good alternative for periodic bone maintenance deploy.Objetivo: Evaluar radiográficamente la remodelación de la cresta ósea periimplantaria en implantes con conexiones protésicas de fricción cono Morse, después de recibir la carga protésica, inmediatamente después de la instalación de la prótesis y después de 12 meses de carga funcional. Materiales y métodos: se instalaron 16 implantes en 10 pacientes y se rehabilitaron con prótesis metalocerámicas parciales, unitarias o múltiples; sometido a la función masticatoria durante el período de 12 meses. Se realizaron radiografías periapicales para determinar la posición de la cresta ósea marginal mesial y distal en relación a la plataforma de cada implante, en el momento de la instalación de las prótesis y 12 meses después. Las imágenes obtenidas a diferentes intervalos fueron digitalizadas y analizadas mediante el software Image JTD. Resultados: En el momento de la instalación de las prótesis, los promedios de las medidas en las superficies distal y mesial fueron de 0,57 mm (desviación estándar 0,45) y 0, 55 mm (desviación estándar 0,41), respectivamente. Después de 12 meses en función, los promedios obtenidos fueron de 0,59 mm (desviación estándar 0,48) en la superficie distal y 0,57 mm en la mesial (desviación estándar 0,34). Conclusión: A través de la evaluación radiográfica se pudo observar que los implantes con plataforma switching ción y conexión protésica con cono morse de fricción mostraron un promedio de 0.2 mm de remodelado óseo cervical, luego de 12 meses en función, y pueden ser una buena alternativa para mantenimiento de los niveles óseos.Objetivo: Avaliar radiograficamente a remodelação da crista óssea peri-implantar em implantes com conexões protéticas do tipo cone morse fricicional, com plataforma switching, após 12 meses de carga protética. Materiais e Métodos: foram instalados 16 implantes, em 10 pacientes e reabilitados com próteses metalocerâmicas parciais, unitárias ou múltiplas; submetidos à função mastigatória durante o período de 12 meses. Radiografias periapicais para determinação da posição da crista óssea marginal mesial e distal em relação a plataforma de cada implante, foram realizadas no momento da instalação das próteses e 12 meses após. As imagens obtidas em diferentes intervalos foram digitalizadas e analisadas no software Image J TD. Resultados: No momento da instalação das próteses, as médias das medidas nas faces distal e mesial foram 0,57 mm (desvio padrão 0,45) e 0,55 mm (desvio padrão 0,41), respectivamente. Após 12 meses em função, as médias obtidas foram 0,59 mm (desvio padrão 0,48) na face distal e 0,57 mm na mesial (desvio padrão 0,34). Conclusão: Por meio da avaliação radiográfica, foi possível observar que os implantes com plataforma switching e conexão protética cone morse friccional apresentaram em média 0,2mm de remodelação óssea cervical, após 12 meses em função, podendo ser uma boa alternativa para manutenção dos níveis ósseos.Research, Society and Development2021-02-13info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1246710.33448/rsd-v10i2.12467Research, Society and Development; Vol. 10 No. 2; e23010212467Research, Society and Development; Vol. 10 Núm. 2; e23010212467Research, Society and Development; v. 10 n. 2; e230102124672525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/12467/11202Copyright (c) 2021 Eduardo Cekaunaskas Kalil; Elaine Marcílio Santos; Alexandre Melloti Dottore; Sergio de Sousa Sobral; Ana Paula Taboada Sobral; Kristianne Porta Santos Fernandes; Lara Jansiski Motta; Anna Carolina Ratto Tempestini Horliana; Andréa Oliver Gomes; Sandra Kalil Bussadorihttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccess Kalil, Eduardo CekaunaskasSantos, Elaine Marcílio Dottore, Alexandre Melloti Sobral, Sergio de Sousa Sobral, Ana Paula Taboada Fernandes, Kristianne Porta Santos Motta, Lara JansiskiHorliana, Anna Carolina Ratto Tempestini Gomes, Andréa Oliver Bussadori, Sandra Kalil 2021-03-02T09:32:39Zoai:ojs.pkp.sfu.ca:article/12467Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:34:02.216777Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
Evaluación radiográfica prospectiva del mantenimiento óseo peri-implantario en implantes osteointegrados con conexión de cono morse por fricción y plataforma de switching: Informes de casos
Avaliação radiográfica prospectiva da manutenção óssea peri-implantar nos implantes osseointegráveis com conexão cone morse friccional e plataforma switching: Relato de casos
title Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
spellingShingle Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
Kalil, Eduardo Cekaunaskas
Odontologia
Implantes dentários
Osseointegração.
Odontología
Implantes dentales
Osteointegración.
Dentistry
Dental implants
Osseointegration.
title_short Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
title_full Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
title_fullStr Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
title_full_unstemmed Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
title_sort Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: Cases report
author Kalil, Eduardo Cekaunaskas
author_facet Kalil, Eduardo Cekaunaskas
Santos, Elaine Marcílio
Dottore, Alexandre Melloti
Sobral, Sergio de Sousa
Sobral, Ana Paula Taboada
Fernandes, Kristianne Porta Santos
Motta, Lara Jansiski
Horliana, Anna Carolina Ratto Tempestini
Gomes, Andréa Oliver
Bussadori, Sandra Kalil
author_role author
author2 Santos, Elaine Marcílio
Dottore, Alexandre Melloti
Sobral, Sergio de Sousa
Sobral, Ana Paula Taboada
Fernandes, Kristianne Porta Santos
Motta, Lara Jansiski
Horliana, Anna Carolina Ratto Tempestini
Gomes, Andréa Oliver
Bussadori, Sandra Kalil
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Kalil, Eduardo Cekaunaskas
Santos, Elaine Marcílio
Dottore, Alexandre Melloti
Sobral, Sergio de Sousa
Sobral, Ana Paula Taboada
Fernandes, Kristianne Porta Santos
Motta, Lara Jansiski
Horliana, Anna Carolina Ratto Tempestini
Gomes, Andréa Oliver
Bussadori, Sandra Kalil
dc.subject.por.fl_str_mv Odontologia
Implantes dentários
Osseointegração.
Odontología
Implantes dentales
Osteointegración.
Dentistry
Dental implants
Osseointegration.
topic Odontologia
Implantes dentários
Osseointegração.
Odontología
Implantes dentales
Osteointegración.
Dentistry
Dental implants
Osseointegration.
description Objective: The aim of the present study was to evaluate radiographically the remodeling of the peri-implant bone crest in prosthetic friction morse cone implants, with platform switching, after 12 months of application of prosthetic load. Materials and Methods: 16 implants were installed, in 10 patients, rehabilitated with partial, single and multiple metal-ceramic prostheses, submitted to prosthetic function in the period of 12 months. Periapical radiographs to measure the distance between the mesial and distal marginal bone crest and the platform of each implant, were performed at the time of installing the prostheses and 12 months later. The images obtained at different intervals were digitized and analyzed using Image J software TD. Results: At the time of installing the prostheses, the averages of measurements on the distal and mesial surfaces were 0.57 mm (standard deviation 0.45) and 0.55 mm (standard deviation 0.41) respectively. After 12 months in function, the averages obtained were 0.59 mm (standard deviation 0.48) on the distal surface and 0.57 mm on the mesial surface, (standard deviation 0.34). Conclusion: In this radiographic evaluation, it was possible to observe that the implants with prosthetic connection of the frictional Cone Morse type with platform switching presented an average of 0.2mm of cervical bone remodeling, after 12 months in function, seeming to be a good alternative for periodic bone maintenance deploy.
publishDate 2021
dc.date.none.fl_str_mv 2021-02-13
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/12467
10.33448/rsd-v10i2.12467
url https://rsdjournal.org/index.php/rsd/article/view/12467
identifier_str_mv 10.33448/rsd-v10i2.12467
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/12467/11202
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 2; e23010212467
Research, Society and Development; Vol. 10 Núm. 2; e23010212467
Research, Society and Development; v. 10 n. 2; e23010212467
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052805268111360