Resumo: Purpose: Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Materials and Methods: Strain gauges were bonded to the sides of five standard abutments that had machined palladiumsilver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Results: Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 µε. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 µε (mean: 173.298 µε) and from -5.62638 to -383.86 µε (mean: 200.474 µε) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Conclusion: Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time. © 2009 by Quintessence Publishing Co Inc.
id UNSP_4312c2f7c4e1a21614259240689b0d99
oai_identifier_str oai:repositorio.unesp.br:11449/231254
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro studyPurpose: Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Materials and Methods: Strain gauges were bonded to the sides of five standard abutments that had machined palladiumsilver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Results: Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 µε. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 µε (mean: 173.298 µε) and from -5.62638 to -383.86 µε (mean: 200.474 µε) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Conclusion: Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time. © 2009 by Quintessence Publishing Co Inc.Department of Prosthodontics Bauru School of Dentistry University of São Paulo, Bauru, SPDepartment of Mechanical Engineering Bauru School of Engineering University of the State of São Paulo, Bauru, SPUniversidade de São Paulo (USP)University of the State of São PauloNeto, Rafael Tobias MorettiMoura, Márcio SilvaSouza, Edson Antônio CapelloRubo, José Henrique2022-04-29T08:44:22Z2022-04-29T08:44:22Z2009-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article391-395International Journal of Prosthodontics, v. 22, n. 4, p. 391-395, 2009.0893-2174http://hdl.handle.net/11449/2312542-s2.0-79953723129Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal of Prosthodonticsinfo:eu-repo/semantics/openAccess2024-06-28T13:54:35Zoai:repositorio.unesp.br:11449/231254Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:06:20.609421Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
title Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
spellingShingle Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
Neto, Rafael Tobias Moretti
title_short Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
title_full Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
title_fullStr Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
title_full_unstemmed Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
title_sort Implant abutment deformation during prosthetic cylinder screw tightening: An in vitro study
author Neto, Rafael Tobias Moretti
author_facet Neto, Rafael Tobias Moretti
Moura, Márcio Silva
Souza, Edson Antônio Capello
Rubo, José Henrique
author_role author
author2 Moura, Márcio Silva
Souza, Edson Antônio Capello
Rubo, José Henrique
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade de São Paulo (USP)
University of the State of São Paulo
dc.contributor.author.fl_str_mv Neto, Rafael Tobias Moretti
Moura, Márcio Silva
Souza, Edson Antônio Capello
Rubo, José Henrique
description Purpose: Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Materials and Methods: Strain gauges were bonded to the sides of five standard abutments that had machined palladiumsilver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Results: Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 µε. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 µε (mean: 173.298 µε) and from -5.62638 to -383.86 µε (mean: 200.474 µε) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Conclusion: Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time. © 2009 by Quintessence Publishing Co Inc.
publishDate 2009
dc.date.none.fl_str_mv 2009-01-01
2022-04-29T08:44:22Z
2022-04-29T08:44:22Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv International Journal of Prosthodontics, v. 22, n. 4, p. 391-395, 2009.
0893-2174
http://hdl.handle.net/11449/231254
2-s2.0-79953723129
identifier_str_mv International Journal of Prosthodontics, v. 22, n. 4, p. 391-395, 2009.
0893-2174
2-s2.0-79953723129
url http://hdl.handle.net/11449/231254
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv International Journal of Prosthodontics
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 391-395
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128461532823552