Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices

Detalhes bibliográficos
Autor(a) principal: Macambira, C. N.
Data de Publicação: 2021
Outros Autores: Agopian, P. G.D. [UNESP], Martino, J. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1149/2162-8777/ac0ecb
http://hdl.handle.net/11449/222065
Resumo: An evaluation of a dielectrically modulated (DM) and a fringing field (FF) biosensor based on a tunneling field-effect transistor (Bio-TFET) by 2D numerical simulation is presented. The bio detection is based on the presence of a biomaterial with a distinct dielectric constant (k) on the sensitivity area. The performance of the devices is compared in terms of drain current in the ambipolar region (i.e., for negative gate voltage in an n-type Bio-nTFET device) due to the variation of the k, drain underlap length (LUD), and the presence of charges (QBio) into the biomaterial/silicon interface. The results show that the DM biosensor with LUD = 25 nm exhibits a higher sensitivity in all k simulated compared with FF biosensor, resulting in more than 2 orders of magnitude for k = 10. In the presence of charges, the DM shows a higher sensitivity in all of the range studied. Higher sensitivity values over a wider range of LUD and QBio are desirable and DM Bio-TFET achieves a better result compared with the FF Bio-TFET. Results show a new outlook for each type of biosensor.
id UNSP_a1db5972e715d06880b070771f214e0b
oai_identifier_str oai:repositorio.unesp.br:11449/222065
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors DevicesAn evaluation of a dielectrically modulated (DM) and a fringing field (FF) biosensor based on a tunneling field-effect transistor (Bio-TFET) by 2D numerical simulation is presented. The bio detection is based on the presence of a biomaterial with a distinct dielectric constant (k) on the sensitivity area. The performance of the devices is compared in terms of drain current in the ambipolar region (i.e., for negative gate voltage in an n-type Bio-nTFET device) due to the variation of the k, drain underlap length (LUD), and the presence of charges (QBio) into the biomaterial/silicon interface. The results show that the DM biosensor with LUD = 25 nm exhibits a higher sensitivity in all k simulated compared with FF biosensor, resulting in more than 2 orders of magnitude for k = 10. In the presence of charges, the DM shows a higher sensitivity in all of the range studied. Higher sensitivity values over a wider range of LUD and QBio are desirable and DM Bio-TFET achieves a better result compared with the FF Bio-TFET. Results show a new outlook for each type of biosensor.LSI/PSI/USP University of Sao PauloUNESP Sao Paulo State UniversityUNESP Sao Paulo State UniversityUniversidade de São Paulo (USP)Universidade Estadual Paulista (UNESP)Macambira, C. N.Agopian, P. G.D. [UNESP]Martino, J. A.2022-04-28T19:42:10Z2022-04-28T19:42:10Z2021-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1149/2162-8777/ac0ecbECS Journal of Solid State Science and Technology, v. 10, n. 7, 2021.2162-87772162-8769http://hdl.handle.net/11449/22206510.1149/2162-8777/ac0ecb2-s2.0-85111333037Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengECS Journal of Solid State Science and Technologyinfo:eu-repo/semantics/openAccess2022-04-28T19:42:10Zoai:repositorio.unesp.br:11449/222065Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T23:07:04.608534Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
title Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
spellingShingle Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
Macambira, C. N.
title_short Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
title_full Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
title_fullStr Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
title_full_unstemmed Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
title_sort Evaluation of Dielectrically Modulated and Fringing Field Tunneling Field Effect Transistor Biosensors Devices
author Macambira, C. N.
author_facet Macambira, C. N.
Agopian, P. G.D. [UNESP]
Martino, J. A.
author_role author
author2 Agopian, P. G.D. [UNESP]
Martino, J. A.
author2_role author
author
dc.contributor.none.fl_str_mv Universidade de São Paulo (USP)
Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Macambira, C. N.
Agopian, P. G.D. [UNESP]
Martino, J. A.
description An evaluation of a dielectrically modulated (DM) and a fringing field (FF) biosensor based on a tunneling field-effect transistor (Bio-TFET) by 2D numerical simulation is presented. The bio detection is based on the presence of a biomaterial with a distinct dielectric constant (k) on the sensitivity area. The performance of the devices is compared in terms of drain current in the ambipolar region (i.e., for negative gate voltage in an n-type Bio-nTFET device) due to the variation of the k, drain underlap length (LUD), and the presence of charges (QBio) into the biomaterial/silicon interface. The results show that the DM biosensor with LUD = 25 nm exhibits a higher sensitivity in all k simulated compared with FF biosensor, resulting in more than 2 orders of magnitude for k = 10. In the presence of charges, the DM shows a higher sensitivity in all of the range studied. Higher sensitivity values over a wider range of LUD and QBio are desirable and DM Bio-TFET achieves a better result compared with the FF Bio-TFET. Results show a new outlook for each type of biosensor.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
2022-04-28T19:42:10Z
2022-04-28T19:42:10Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1149/2162-8777/ac0ecb
ECS Journal of Solid State Science and Technology, v. 10, n. 7, 2021.
2162-8777
2162-8769
http://hdl.handle.net/11449/222065
10.1149/2162-8777/ac0ecb
2-s2.0-85111333037
url http://dx.doi.org/10.1149/2162-8777/ac0ecb
http://hdl.handle.net/11449/222065
identifier_str_mv ECS Journal of Solid State Science and Technology, v. 10, n. 7, 2021.
2162-8777
2162-8769
10.1149/2162-8777/ac0ecb
2-s2.0-85111333037
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv ECS Journal of Solid State Science and Technology
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129491075072000