Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants

Detalhes bibliográficos
Autor(a) principal: Harb, Samarah V. [UNESP]
Data de Publicação: 2020
Outros Autores: Bassous, Nicole J., de Souza, Thiago A.C. [UNESP], Trentin, Andressa [UNESP], Pulcinelli, Sandra H. [UNESP], Santilli, Celso V. [UNESP], Webster, Thomas J., Lobo, Anderson O., Hammer, Peter [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.msec.2020.111149
http://hdl.handle.net/11449/201875
Resumo: Organic-inorganic hybrid coatings deposited on different types of metallic alloys have shown outstanding anticorrosive performance. The incorporation of osteoconductive additives such as hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) into organic-inorganic hybrid coatings is promising to improve the osseointegration and corrosion resistance of Ti6Al4V alloys, which are the most widely used metallic orthopedic and dental implant materials today. Therefore, this study evaluated the capability of poly(methyl methacrylate) (PMMA)-TiO2 and PMMA-ZrO2 hybrid coatings modified with HA and β-TCP to act as bioactive and corrosion protection coatings for Ti6Al4V alloys. In terms of cell growth and mineralization, osteoblast viability, Ca+2 deposition and alkaline phosphatase assays revealed a significant improvement for the HA and β-TCP modified coatings, compared to the bare alloy. This can be explained by an increase in nanoscale roughness and associated higher surface free energy, which lead to enhanced protein adsorption to promote osteoblast attachment and functions on the coatings. The effect of HA and β-TCP additives on the anticorrosive efficiency was studied by electrochemical impedance spectroscopy (EIS) in a simulated body fluid (SBF) solution. The coatings presented a low-frequency impedance modulus of up to 430 GΩ cm2, 5 decades higher than the bare Ti6Al4V alloy. These findings provide clear evidence of the beneficial role of HA and β-TCP modified hybrid coatings, improving both the biocompatibility and corrosion resistance of the Ti6Al4V alloy.
id UNSP_b2e78ac319e311400337e13f6476c69e
oai_identifier_str oai:repositorio.unesp.br:11449/201875
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implantsBioactive coatingCorrosion protectionNanocomposite coatingOrganic-inorganic hybridTi6Al4V alloyOrganic-inorganic hybrid coatings deposited on different types of metallic alloys have shown outstanding anticorrosive performance. The incorporation of osteoconductive additives such as hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) into organic-inorganic hybrid coatings is promising to improve the osseointegration and corrosion resistance of Ti6Al4V alloys, which are the most widely used metallic orthopedic and dental implant materials today. Therefore, this study evaluated the capability of poly(methyl methacrylate) (PMMA)-TiO2 and PMMA-ZrO2 hybrid coatings modified with HA and β-TCP to act as bioactive and corrosion protection coatings for Ti6Al4V alloys. In terms of cell growth and mineralization, osteoblast viability, Ca+2 deposition and alkaline phosphatase assays revealed a significant improvement for the HA and β-TCP modified coatings, compared to the bare alloy. This can be explained by an increase in nanoscale roughness and associated higher surface free energy, which lead to enhanced protein adsorption to promote osteoblast attachment and functions on the coatings. The effect of HA and β-TCP additives on the anticorrosive efficiency was studied by electrochemical impedance spectroscopy (EIS) in a simulated body fluid (SBF) solution. The coatings presented a low-frequency impedance modulus of up to 430 GΩ cm2, 5 decades higher than the bare Ti6Al4V alloy. These findings provide clear evidence of the beneficial role of HA and β-TCP modified hybrid coatings, improving both the biocompatibility and corrosion resistance of the Ti6Al4V alloy.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)São Paulo State University (UNESP) Institute of ChemistryDepartment of Chemical Engineering Northeastern UniversityFederal University of Piauí (UFPI) Interdisciplinary Laboratory for Advanced Materials (LIMAV) Department of Materials EngineeringSão Paulo State University (UNESP) Institute of ChemistryCAPES: 001FAPESP: 2015/09342-7FAPESP: 2015/11907-2FAPESP: 2017/02899-1FAPESP: 2017/14061-2CNPq: 303752/2017-3CNPq: 307905/2018-7CNPq: 421081/2016-3CNPq: 424133/2016-4Universidade Estadual Paulista (Unesp)Northeastern UniversityInterdisciplinary Laboratory for Advanced Materials (LIMAV)Harb, Samarah V. [UNESP]Bassous, Nicole J.de Souza, Thiago A.C. [UNESP]Trentin, Andressa [UNESP]Pulcinelli, Sandra H. [UNESP]Santilli, Celso V. [UNESP]Webster, Thomas J.Lobo, Anderson O.Hammer, Peter [UNESP]2020-12-12T02:44:08Z2020-12-12T02:44:08Z2020-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1016/j.msec.2020.111149Materials Science and Engineering C, v. 116.1873-01910928-4931http://hdl.handle.net/11449/20187510.1016/j.msec.2020.1111492-s2.0-8508644816555842986818708650000-0002-8356-8093Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMaterials Science and Engineering Cinfo:eu-repo/semantics/openAccess2021-10-23T02:05:54Zoai:repositorio.unesp.br:11449/201875Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:16:30.605646Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
title Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
spellingShingle Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
Harb, Samarah V. [UNESP]
Bioactive coating
Corrosion protection
Nanocomposite coating
Organic-inorganic hybrid
Ti6Al4V alloy
title_short Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
title_full Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
title_fullStr Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
title_full_unstemmed Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
title_sort Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants
author Harb, Samarah V. [UNESP]
author_facet Harb, Samarah V. [UNESP]
Bassous, Nicole J.
de Souza, Thiago A.C. [UNESP]
Trentin, Andressa [UNESP]
Pulcinelli, Sandra H. [UNESP]
Santilli, Celso V. [UNESP]
Webster, Thomas J.
Lobo, Anderson O.
Hammer, Peter [UNESP]
author_role author
author2 Bassous, Nicole J.
de Souza, Thiago A.C. [UNESP]
Trentin, Andressa [UNESP]
Pulcinelli, Sandra H. [UNESP]
Santilli, Celso V. [UNESP]
Webster, Thomas J.
Lobo, Anderson O.
Hammer, Peter [UNESP]
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Northeastern University
Interdisciplinary Laboratory for Advanced Materials (LIMAV)
dc.contributor.author.fl_str_mv Harb, Samarah V. [UNESP]
Bassous, Nicole J.
de Souza, Thiago A.C. [UNESP]
Trentin, Andressa [UNESP]
Pulcinelli, Sandra H. [UNESP]
Santilli, Celso V. [UNESP]
Webster, Thomas J.
Lobo, Anderson O.
Hammer, Peter [UNESP]
dc.subject.por.fl_str_mv Bioactive coating
Corrosion protection
Nanocomposite coating
Organic-inorganic hybrid
Ti6Al4V alloy
topic Bioactive coating
Corrosion protection
Nanocomposite coating
Organic-inorganic hybrid
Ti6Al4V alloy
description Organic-inorganic hybrid coatings deposited on different types of metallic alloys have shown outstanding anticorrosive performance. The incorporation of osteoconductive additives such as hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) into organic-inorganic hybrid coatings is promising to improve the osseointegration and corrosion resistance of Ti6Al4V alloys, which are the most widely used metallic orthopedic and dental implant materials today. Therefore, this study evaluated the capability of poly(methyl methacrylate) (PMMA)-TiO2 and PMMA-ZrO2 hybrid coatings modified with HA and β-TCP to act as bioactive and corrosion protection coatings for Ti6Al4V alloys. In terms of cell growth and mineralization, osteoblast viability, Ca+2 deposition and alkaline phosphatase assays revealed a significant improvement for the HA and β-TCP modified coatings, compared to the bare alloy. This can be explained by an increase in nanoscale roughness and associated higher surface free energy, which lead to enhanced protein adsorption to promote osteoblast attachment and functions on the coatings. The effect of HA and β-TCP additives on the anticorrosive efficiency was studied by electrochemical impedance spectroscopy (EIS) in a simulated body fluid (SBF) solution. The coatings presented a low-frequency impedance modulus of up to 430 GΩ cm2, 5 decades higher than the bare Ti6Al4V alloy. These findings provide clear evidence of the beneficial role of HA and β-TCP modified hybrid coatings, improving both the biocompatibility and corrosion resistance of the Ti6Al4V alloy.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-12T02:44:08Z
2020-12-12T02:44:08Z
2020-11-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.msec.2020.111149
Materials Science and Engineering C, v. 116.
1873-0191
0928-4931
http://hdl.handle.net/11449/201875
10.1016/j.msec.2020.111149
2-s2.0-85086448165
5584298681870865
0000-0002-8356-8093
url http://dx.doi.org/10.1016/j.msec.2020.111149
http://hdl.handle.net/11449/201875
identifier_str_mv Materials Science and Engineering C, v. 116.
1873-0191
0928-4931
10.1016/j.msec.2020.111149
2-s2.0-85086448165
5584298681870865
0000-0002-8356-8093
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Materials Science and Engineering C
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129044457193472