Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis

Detalhes bibliográficos
Autor(a) principal: Jaime-Pérez,José Carlos
Data de Publicação: 2015
Outros Autores: García-Arellano,Gisela, Méndez-Ramírez,Nereida, González-Llano,Óscar, Gómez-Almaguer,David
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista brasileira de hematologia e hemoterapia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178
Resumo: Objective: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test prob- ability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. Methods: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 µg/L in women and a cord blood serum ferritin <35.0 µg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. Results: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 µg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). Conclusion: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns.
id ABHHTC-1_01129c33a8bf45b90e247d95066cc50f
oai_identifier_str oai:scielo:S1516-84842015000300178
network_acronym_str ABHHTC-1
network_name_str Revista brasileira de hematologia e hemoterapia (Online)
repository_id_str
spelling Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysisFerritinsAnemia, Iron-deficiencyDiagnostic tests, Routine Objective: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test prob- ability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. Methods: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 µg/L in women and a cord blood serum ferritin <35.0 µg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. Results: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 µg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). Conclusion: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns. Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular2015-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178Revista Brasileira de Hematologia e Hemoterapia v.37 n.3 2015reponame:Revista brasileira de hematologia e hemoterapia (Online)instname:Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC)instacron:ABHHTC10.1016/j.bjhh.2015.02.002info:eu-repo/semantics/openAccessJaime-Pérez,José CarlosGarcía-Arellano,GiselaMéndez-Ramírez,NereidaGonzález-Llano,ÓscarGómez-Almaguer,Davideng2015-07-17T00:00:00Zoai:scielo:S1516-84842015000300178Revistahttp://www.rbhh.org/pt/archivo/https://old.scielo.br/oai/scielo-oai.phpsbhh@terra.com.br||secretaria@rbhh.org1806-08701516-8484opendoar:2015-07-17T00:00Revista brasileira de hematologia e hemoterapia (Online) - Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC)false
dc.title.none.fl_str_mv Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
title Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
spellingShingle Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
Jaime-Pérez,José Carlos
Ferritins
Anemia, Iron-deficiency
Diagnostic tests, Routine
title_short Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
title_full Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
title_fullStr Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
title_full_unstemmed Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
title_sort Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
author Jaime-Pérez,José Carlos
author_facet Jaime-Pérez,José Carlos
García-Arellano,Gisela
Méndez-Ramírez,Nereida
González-Llano,Óscar
Gómez-Almaguer,David
author_role author
author2 García-Arellano,Gisela
Méndez-Ramírez,Nereida
González-Llano,Óscar
Gómez-Almaguer,David
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Jaime-Pérez,José Carlos
García-Arellano,Gisela
Méndez-Ramírez,Nereida
González-Llano,Óscar
Gómez-Almaguer,David
dc.subject.por.fl_str_mv Ferritins
Anemia, Iron-deficiency
Diagnostic tests, Routine
topic Ferritins
Anemia, Iron-deficiency
Diagnostic tests, Routine
description Objective: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test prob- ability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. Methods: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 µg/L in women and a cord blood serum ferritin <35.0 µg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. Results: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 µg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). Conclusion: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns.
publishDate 2015
dc.date.none.fl_str_mv 2015-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjhh.2015.02.002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular
publisher.none.fl_str_mv Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular
dc.source.none.fl_str_mv Revista Brasileira de Hematologia e Hemoterapia v.37 n.3 2015
reponame:Revista brasileira de hematologia e hemoterapia (Online)
instname:Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC)
instacron:ABHHTC
instname_str Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC)
instacron_str ABHHTC
institution ABHHTC
reponame_str Revista brasileira de hematologia e hemoterapia (Online)
collection Revista brasileira de hematologia e hemoterapia (Online)
repository.name.fl_str_mv Revista brasileira de hematologia e hemoterapia (Online) - Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC)
repository.mail.fl_str_mv sbhh@terra.com.br||secretaria@rbhh.org
_version_ 1754213112460869632