Axis instrumentation: surgical results
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos de neuro-psiquiatria (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007 |
Resumo: | OBJECTIVE: Evaluate the surgical results of axis screw instrumentation. METHODS: Retrospective evaluation of the clinical and radiological data of patients submitted to axis fixation using screws. RESULTS: Seventeen patients were surgically treated. The mean age was 41.8 years (range: 12-73). Spinal cord trauma was the most common cause of instability (8 patients - 47%). Bilateral axis fixation was performed in all cases, except one, with laminar screw (total of 33 axis screws). Seven patients (41.1%) underwent bilateral pars screws; laminar screws were used in six cases and pedicular screws were used in two. In two cases, we performed a hybrid construction (laminar + pars and pedicle + pars). There was no neurological worsening or death, nor complications directly related to use axis screws. CONCLUSION: Axis instrumentation was effective and safe, regardless of the technique used for stabilization. Based on our learnt experience, we proposed an algorithm to choose the best technique for axis screw fixation. |
id |
ABNEURO-1_cb34994607155f7aab696b8c72c7f830 |
---|---|
oai_identifier_str |
oai:scielo:S0004-282X2012001100007 |
network_acronym_str |
ABNEURO-1 |
network_name_str |
Arquivos de neuro-psiquiatria (Online) |
repository_id_str |
|
spelling |
Axis instrumentation: surgical resultsaxisinstrumentationpedicleparslaminarbone screwsOBJECTIVE: Evaluate the surgical results of axis screw instrumentation. METHODS: Retrospective evaluation of the clinical and radiological data of patients submitted to axis fixation using screws. RESULTS: Seventeen patients were surgically treated. The mean age was 41.8 years (range: 12-73). Spinal cord trauma was the most common cause of instability (8 patients - 47%). Bilateral axis fixation was performed in all cases, except one, with laminar screw (total of 33 axis screws). Seven patients (41.1%) underwent bilateral pars screws; laminar screws were used in six cases and pedicular screws were used in two. In two cases, we performed a hybrid construction (laminar + pars and pedicle + pars). There was no neurological worsening or death, nor complications directly related to use axis screws. CONCLUSION: Axis instrumentation was effective and safe, regardless of the technique used for stabilization. Based on our learnt experience, we proposed an algorithm to choose the best technique for axis screw fixation.Academia Brasileira de Neurologia - ABNEURO2012-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007Arquivos de Neuro-Psiquiatria v.70 n.11 2012reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/S0004-282X2012001100007info:eu-repo/semantics/openAccessJoaquim,Andrei F.Ghizoni,EnricoAnderle,Diogo V.Oliveira,Evandro deTedeschi,Heldereng2012-11-14T00:00:00Zoai:scielo:S0004-282X2012001100007Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2012-11-14T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse |
dc.title.none.fl_str_mv |
Axis instrumentation: surgical results |
title |
Axis instrumentation: surgical results |
spellingShingle |
Axis instrumentation: surgical results Joaquim,Andrei F. axis instrumentation pedicle pars laminar bone screws |
title_short |
Axis instrumentation: surgical results |
title_full |
Axis instrumentation: surgical results |
title_fullStr |
Axis instrumentation: surgical results |
title_full_unstemmed |
Axis instrumentation: surgical results |
title_sort |
Axis instrumentation: surgical results |
author |
Joaquim,Andrei F. |
author_facet |
Joaquim,Andrei F. Ghizoni,Enrico Anderle,Diogo V. Oliveira,Evandro de Tedeschi,Helder |
author_role |
author |
author2 |
Ghizoni,Enrico Anderle,Diogo V. Oliveira,Evandro de Tedeschi,Helder |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Joaquim,Andrei F. Ghizoni,Enrico Anderle,Diogo V. Oliveira,Evandro de Tedeschi,Helder |
dc.subject.por.fl_str_mv |
axis instrumentation pedicle pars laminar bone screws |
topic |
axis instrumentation pedicle pars laminar bone screws |
description |
OBJECTIVE: Evaluate the surgical results of axis screw instrumentation. METHODS: Retrospective evaluation of the clinical and radiological data of patients submitted to axis fixation using screws. RESULTS: Seventeen patients were surgically treated. The mean age was 41.8 years (range: 12-73). Spinal cord trauma was the most common cause of instability (8 patients - 47%). Bilateral axis fixation was performed in all cases, except one, with laminar screw (total of 33 axis screws). Seven patients (41.1%) underwent bilateral pars screws; laminar screws were used in six cases and pedicular screws were used in two. In two cases, we performed a hybrid construction (laminar + pars and pedicle + pars). There was no neurological worsening or death, nor complications directly related to use axis screws. CONCLUSION: Axis instrumentation was effective and safe, regardless of the technique used for stabilization. Based on our learnt experience, we proposed an algorithm to choose the best technique for axis screw fixation. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-11-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-282X2012001100007 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
dc.source.none.fl_str_mv |
Arquivos de Neuro-Psiquiatria v.70 n.11 2012 reponame:Arquivos de neuro-psiquiatria (Online) instname:Academia Brasileira de Neurologia instacron:ABNEURO |
instname_str |
Academia Brasileira de Neurologia |
instacron_str |
ABNEURO |
institution |
ABNEURO |
reponame_str |
Arquivos de neuro-psiquiatria (Online) |
collection |
Arquivos de neuro-psiquiatria (Online) |
repository.name.fl_str_mv |
Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia |
repository.mail.fl_str_mv |
||revista.arquivos@abneuro.org |
_version_ |
1754212773840027648 |