Axis instrumentation: surgical results

Detalhes bibliográficos
Autor(a) principal: Joaquim,Andrei F.
Data de Publicação: 2012
Outros Autores: Ghizoni,Enrico, Anderle,Diogo V., Oliveira,Evandro de, Tedeschi,Helder
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos de neuro-psiquiatria (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007
Resumo: OBJECTIVE: Evaluate the surgical results of axis screw instrumentation. METHODS: Retrospective evaluation of the clinical and radiological data of patients submitted to axis fixation using screws. RESULTS: Seventeen patients were surgically treated. The mean age was 41.8 years (range: 12-73). Spinal cord trauma was the most common cause of instability (8 patients - 47%). Bilateral axis fixation was performed in all cases, except one, with laminar screw (total of 33 axis screws). Seven patients (41.1%) underwent bilateral pars screws; laminar screws were used in six cases and pedicular screws were used in two. In two cases, we performed a hybrid construction (laminar + pars and pedicle + pars). There was no neurological worsening or death, nor complications directly related to use axis screws. CONCLUSION: Axis instrumentation was effective and safe, regardless of the technique used for stabilization. Based on our learnt experience, we proposed an algorithm to choose the best technique for axis screw fixation.
id ABNEURO-1_cb34994607155f7aab696b8c72c7f830
oai_identifier_str oai:scielo:S0004-282X2012001100007
network_acronym_str ABNEURO-1
network_name_str Arquivos de neuro-psiquiatria (Online)
repository_id_str
spelling Axis instrumentation: surgical resultsaxisinstrumentationpedicleparslaminarbone screwsOBJECTIVE: Evaluate the surgical results of axis screw instrumentation. METHODS: Retrospective evaluation of the clinical and radiological data of patients submitted to axis fixation using screws. RESULTS: Seventeen patients were surgically treated. The mean age was 41.8 years (range: 12-73). Spinal cord trauma was the most common cause of instability (8 patients - 47%). Bilateral axis fixation was performed in all cases, except one, with laminar screw (total of 33 axis screws). Seven patients (41.1%) underwent bilateral pars screws; laminar screws were used in six cases and pedicular screws were used in two. In two cases, we performed a hybrid construction (laminar + pars and pedicle + pars). There was no neurological worsening or death, nor complications directly related to use axis screws. CONCLUSION: Axis instrumentation was effective and safe, regardless of the technique used for stabilization. Based on our learnt experience, we proposed an algorithm to choose the best technique for axis screw fixation.Academia Brasileira de Neurologia - ABNEURO2012-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007Arquivos de Neuro-Psiquiatria v.70 n.11 2012reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/S0004-282X2012001100007info:eu-repo/semantics/openAccessJoaquim,Andrei F.Ghizoni,EnricoAnderle,Diogo V.Oliveira,Evandro deTedeschi,Heldereng2012-11-14T00:00:00Zoai:scielo:S0004-282X2012001100007Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2012-11-14T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse
dc.title.none.fl_str_mv Axis instrumentation: surgical results
title Axis instrumentation: surgical results
spellingShingle Axis instrumentation: surgical results
Joaquim,Andrei F.
axis
instrumentation
pedicle
pars
laminar
bone screws
title_short Axis instrumentation: surgical results
title_full Axis instrumentation: surgical results
title_fullStr Axis instrumentation: surgical results
title_full_unstemmed Axis instrumentation: surgical results
title_sort Axis instrumentation: surgical results
author Joaquim,Andrei F.
author_facet Joaquim,Andrei F.
Ghizoni,Enrico
Anderle,Diogo V.
Oliveira,Evandro de
Tedeschi,Helder
author_role author
author2 Ghizoni,Enrico
Anderle,Diogo V.
Oliveira,Evandro de
Tedeschi,Helder
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Joaquim,Andrei F.
Ghizoni,Enrico
Anderle,Diogo V.
Oliveira,Evandro de
Tedeschi,Helder
dc.subject.por.fl_str_mv axis
instrumentation
pedicle
pars
laminar
bone screws
topic axis
instrumentation
pedicle
pars
laminar
bone screws
description OBJECTIVE: Evaluate the surgical results of axis screw instrumentation. METHODS: Retrospective evaluation of the clinical and radiological data of patients submitted to axis fixation using screws. RESULTS: Seventeen patients were surgically treated. The mean age was 41.8 years (range: 12-73). Spinal cord trauma was the most common cause of instability (8 patients - 47%). Bilateral axis fixation was performed in all cases, except one, with laminar screw (total of 33 axis screws). Seven patients (41.1%) underwent bilateral pars screws; laminar screws were used in six cases and pedicular screws were used in two. In two cases, we performed a hybrid construction (laminar + pars and pedicle + pars). There was no neurological worsening or death, nor complications directly related to use axis screws. CONCLUSION: Axis instrumentation was effective and safe, regardless of the technique used for stabilization. Based on our learnt experience, we proposed an algorithm to choose the best technique for axis screw fixation.
publishDate 2012
dc.date.none.fl_str_mv 2012-11-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2012001100007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-282X2012001100007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
dc.source.none.fl_str_mv Arquivos de Neuro-Psiquiatria v.70 n.11 2012
reponame:Arquivos de neuro-psiquiatria (Online)
instname:Academia Brasileira de Neurologia
instacron:ABNEURO
instname_str Academia Brasileira de Neurologia
instacron_str ABNEURO
institution ABNEURO
reponame_str Arquivos de neuro-psiquiatria (Online)
collection Arquivos de neuro-psiquiatria (Online)
repository.name.fl_str_mv Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia
repository.mail.fl_str_mv ||revista.arquivos@abneuro.org
_version_ 1754212773840027648