A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes

Bibliographic Details
Main Author: Silva, Luiz Carlos Pereira da, 1972-
Publication Date: 2018
Format: Article
Language: por
Source: Repositório da Produção Científica e Intelectual da Unicamp
Download full: https://hdl.handle.net/20.500.12733/1651741
Summary: The impact of non-linear loads in electrical systems is a subject that has been of concern of the scientific community for quite some time. More recently, in addition to the aspects associated to power quality, billing concerns also became part of the agenda of the professionals that actuate on in this important area. In this context, this work presents an electronic device, named as Dimmer Flex, which makes it easier to explore the impact of electronic switching on the electrical current that feeds a linear load. By means of the prototype presented at this paper it is possible to analyze the impacts of the switching in the measurement, and consequently, in the energy billing, considering any pre-specified capacitive or inductive power factor value. Once this is a relatively new subject, additional research is still required for deepening the conclusions and results, which could, in turn, lead to the revision of current methods used for the purpose of measurement and billing of electrical power.
id CAMP_677227670ff3e23063bfedd36d76b545
oai_identifier_str oai:https://www.repositorio.unicamp.br/:1189746
network_acronym_str CAMP
network_name_str Repositório da Produção Científica e Intelectual da Unicamp
repository_id_str
spelling A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposesCircuitos integradosEnergia elétricaIntegrated circuitsElectric powerElectronic loadsIntegrated circuit TCA785Power factorBillingDimmer flexArtigo originalThe impact of non-linear loads in electrical systems is a subject that has been of concern of the scientific community for quite some time. More recently, in addition to the aspects associated to power quality, billing concerns also became part of the agenda of the professionals that actuate on in this important area. In this context, this work presents an electronic device, named as Dimmer Flex, which makes it easier to explore the impact of electronic switching on the electrical current that feeds a linear load. By means of the prototype presented at this paper it is possible to analyze the impacts of the switching in the measurement, and consequently, in the energy billing, considering any pre-specified capacitive or inductive power factor value. Once this is a relatively new subject, additional research is still required for deepening the conclusions and results, which could, in turn, lead to the revision of current methods used for the purpose of measurement and billing of electrical power.FechadoUNIVERSIDADE ESTADUAL DE CAMPINASSilva, Luiz Carlos Pereira da, 1972-2018info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.12733/1651741SILVA, Luiz Carlos Pereira da. A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes. IEEE America Latina. Revista = IEEE Latin America transactions. Institute of Electrical and Electronics Engineers, 2018.. Vol. 16, no. 1 (jan., 2018), p. 88-95. Disponível em: https://hdl.handle.net/20.500.12733/1651741. Acesso em: 7 mai. 2024.https://repositorio.unicamp.br/acervo/detalhe/1189746porreponame:Repositório da Produção Científica e Intelectual da Unicampinstname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2023-10-10T14:37:21Zoai:https://www.repositorio.unicamp.br/:1189746Repositório InstitucionalPUBhttp://repositorio.unicamp.br/oai/requestreposip@unicamp.bropendoar:2023-10-10T14:37:21Repositório da Produção Científica e Intelectual da Unicamp - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
title A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
spellingShingle A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
Silva, Luiz Carlos Pereira da, 1972-
Circuitos integrados
Energia elétrica
Integrated circuits
Electric power
Electronic loads
Integrated circuit TCA785
Power factor
Billing
Dimmer flex
Artigo original
title_short A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
title_full A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
title_fullStr A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
title_full_unstemmed A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
title_sort A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes
author Silva, Luiz Carlos Pereira da, 1972-
author_facet Silva, Luiz Carlos Pereira da, 1972-
author_role author
dc.contributor.none.fl_str_mv UNIVERSIDADE ESTADUAL DE CAMPINAS
dc.contributor.author.fl_str_mv Silva, Luiz Carlos Pereira da, 1972-
dc.subject.por.fl_str_mv Circuitos integrados
Energia elétrica
Integrated circuits
Electric power
Electronic loads
Integrated circuit TCA785
Power factor
Billing
Dimmer flex
Artigo original
topic Circuitos integrados
Energia elétrica
Integrated circuits
Electric power
Electronic loads
Integrated circuit TCA785
Power factor
Billing
Dimmer flex
Artigo original
description The impact of non-linear loads in electrical systems is a subject that has been of concern of the scientific community for quite some time. More recently, in addition to the aspects associated to power quality, billing concerns also became part of the agenda of the professionals that actuate on in this important area. In this context, this work presents an electronic device, named as Dimmer Flex, which makes it easier to explore the impact of electronic switching on the electrical current that feeds a linear load. By means of the prototype presented at this paper it is possible to analyze the impacts of the switching in the measurement, and consequently, in the energy billing, considering any pre-specified capacitive or inductive power factor value. Once this is a relatively new subject, additional research is still required for deepening the conclusions and results, which could, in turn, lead to the revision of current methods used for the purpose of measurement and billing of electrical power.
publishDate 2018
dc.date.none.fl_str_mv 2018
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/20.500.12733/1651741
SILVA, Luiz Carlos Pereira da. A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes. IEEE America Latina. Revista = IEEE Latin America transactions. Institute of Electrical and Electronics Engineers, 2018.. Vol. 16, no. 1 (jan., 2018), p. 88-95. Disponível em: https://hdl.handle.net/20.500.12733/1651741. Acesso em: 7 mai. 2024.
url https://hdl.handle.net/20.500.12733/1651741
identifier_str_mv SILVA, Luiz Carlos Pereira da. A new electronic device for analyzing the impact of non-linear loads in the electrical power measurement for billing purposes. IEEE America Latina. Revista = IEEE Latin America transactions. Institute of Electrical and Electronics Engineers, 2018.. Vol. 16, no. 1 (jan., 2018), p. 88-95. Disponível em: https://hdl.handle.net/20.500.12733/1651741. Acesso em: 7 mai. 2024.
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://repositorio.unicamp.br/acervo/detalhe/1189746
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório da Produção Científica e Intelectual da Unicamp
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Repositório da Produção Científica e Intelectual da Unicamp
collection Repositório da Produção Científica e Intelectual da Unicamp
repository.name.fl_str_mv Repositório da Produção Científica e Intelectual da Unicamp - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv reposip@unicamp.br
_version_ 1799030821444648960