Resumo: ABSTRACT Objective: to assess safety, efficacy and quality of life in patients with benign pleural effusions undergong pleural drainage with Wayne pleural catheter (DW) in an outpatient setting. Method: this is a prospective study, in which 47 patients were evaluated between July 2017 and October 2018. Patients with non-malignant pleural effusions underwent pleural drainage with clinical evolution compatible with outpatient care were included. Patients who underwent drainage due to other conditions and patients were excluded. Results: after catheter placement, the mean length of hospital stay was 3.14 (± 3.85) days, and 21 patients (44.68%) were discharged within 24 hours. The mean time with the catheter was 12.63 (± 7.37) days. The analysis of the pleural fluid was transudate in 87.3% of cases and exudate in 12.3%. The causes of pleural effusion were heart failure (72.3%), renal failure (19.1%), liver failure (6.3%) and pneumonia (8.5%). The quality of life, analyzed according to the parameters of the questionnaire SF 36, showed low average values when compared to other studies. Analyzing each descriptor, the average was greater only in the limitation related to physical aspects. In the other descriptors, the results were similar, but smaller. Conclusion: the outpatient use of pleural catheters of the Wayne type (pigtail) proved to be feasible, safe and with a low associated infection rate. This is a viable option for selected patients.
id CBC-1_aafb6950e5673a65c83b34c104dd73f2
oai_identifier_str oai:scielo:S0100-69912022000100203
network_acronym_str CBC-1
network_name_str Revista do Colégio Brasileiro de Cirurgiões
repository_id_str
spelling Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of lifePleural EffusionOutpatientsThoracic SurgeryABSTRACT Objective: to assess safety, efficacy and quality of life in patients with benign pleural effusions undergong pleural drainage with Wayne pleural catheter (DW) in an outpatient setting. Method: this is a prospective study, in which 47 patients were evaluated between July 2017 and October 2018. Patients with non-malignant pleural effusions underwent pleural drainage with clinical evolution compatible with outpatient care were included. Patients who underwent drainage due to other conditions and patients were excluded. Results: after catheter placement, the mean length of hospital stay was 3.14 (± 3.85) days, and 21 patients (44.68%) were discharged within 24 hours. The mean time with the catheter was 12.63 (± 7.37) days. The analysis of the pleural fluid was transudate in 87.3% of cases and exudate in 12.3%. The causes of pleural effusion were heart failure (72.3%), renal failure (19.1%), liver failure (6.3%) and pneumonia (8.5%). The quality of life, analyzed according to the parameters of the questionnaire SF 36, showed low average values when compared to other studies. Analyzing each descriptor, the average was greater only in the limitation related to physical aspects. In the other descriptors, the results were similar, but smaller. Conclusion: the outpatient use of pleural catheters of the Wayne type (pigtail) proved to be feasible, safe and with a low associated infection rate. This is a viable option for selected patients.Colégio Brasileiro de Cirurgiões2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912022000100203Revista do Colégio Brasileiro de Cirurgiões v.49 2022reponame:Revista do Colégio Brasileiro de Cirurgiõesinstname:Colégio Brasileiro de Cirurgiões (CBC)instacron:CBC10.1590/0100-6991e-20213139info:eu-repo/semantics/openAccessMIOTTO,ANDRÉHONDA,PEDRO AUGUSTO ANTUNESDIAS,DANIELA CRISTINA ALMEIDARIVABEN,JORGE HENRIQUEBOTTER,MARCIOBINOTTO,BRUNO FERNANDOLOPEZ,JULIO MOTT ANCONAeng2022-02-25T00:00:00Zoai:scielo:S0100-69912022000100203Revistahttp://www.scielo.br/rcbcONGhttps://old.scielo.br/oai/scielo-oai.php||revistacbc@cbc.org.br1809-45460100-6991opendoar:2022-02-25T00:00Revista do Colégio Brasileiro de Cirurgiões - Colégio Brasileiro de Cirurgiões (CBC)false
dc.title.none.fl_str_mv Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
title Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
spellingShingle Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
MIOTTO,ANDRÉ
Pleural Effusion
Outpatients
Thoracic Surgery
title_short Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
title_full Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
title_fullStr Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
title_full_unstemmed Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
title_sort Early discharge for patients with benign pleural effusions using a Wayne catheter (pigtail) chest drain - analysis of safety, complications, and quality of life
author MIOTTO,ANDRÉ
author_facet MIOTTO,ANDRÉ
HONDA,PEDRO AUGUSTO ANTUNES
DIAS,DANIELA CRISTINA ALMEIDA
RIVABEN,JORGE HENRIQUE
BOTTER,MARCIO
BINOTTO,BRUNO FERNANDO
LOPEZ,JULIO MOTT ANCONA
author_role author
author2 HONDA,PEDRO AUGUSTO ANTUNES
DIAS,DANIELA CRISTINA ALMEIDA
RIVABEN,JORGE HENRIQUE
BOTTER,MARCIO
BINOTTO,BRUNO FERNANDO
LOPEZ,JULIO MOTT ANCONA
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv MIOTTO,ANDRÉ
HONDA,PEDRO AUGUSTO ANTUNES
DIAS,DANIELA CRISTINA ALMEIDA
RIVABEN,JORGE HENRIQUE
BOTTER,MARCIO
BINOTTO,BRUNO FERNANDO
LOPEZ,JULIO MOTT ANCONA
dc.subject.por.fl_str_mv Pleural Effusion
Outpatients
Thoracic Surgery
topic Pleural Effusion
Outpatients
Thoracic Surgery
description ABSTRACT Objective: to assess safety, efficacy and quality of life in patients with benign pleural effusions undergong pleural drainage with Wayne pleural catheter (DW) in an outpatient setting. Method: this is a prospective study, in which 47 patients were evaluated between July 2017 and October 2018. Patients with non-malignant pleural effusions underwent pleural drainage with clinical evolution compatible with outpatient care were included. Patients who underwent drainage due to other conditions and patients were excluded. Results: after catheter placement, the mean length of hospital stay was 3.14 (± 3.85) days, and 21 patients (44.68%) were discharged within 24 hours. The mean time with the catheter was 12.63 (± 7.37) days. The analysis of the pleural fluid was transudate in 87.3% of cases and exudate in 12.3%. The causes of pleural effusion were heart failure (72.3%), renal failure (19.1%), liver failure (6.3%) and pneumonia (8.5%). The quality of life, analyzed according to the parameters of the questionnaire SF 36, showed low average values when compared to other studies. Analyzing each descriptor, the average was greater only in the limitation related to physical aspects. In the other descriptors, the results were similar, but smaller. Conclusion: the outpatient use of pleural catheters of the Wayne type (pigtail) proved to be feasible, safe and with a low associated infection rate. This is a viable option for selected patients.
publishDate 2022
dc.date.none.fl_str_mv 2022-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912022000100203
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912022000100203
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0100-6991e-20213139
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Colégio Brasileiro de Cirurgiões
publisher.none.fl_str_mv Colégio Brasileiro de Cirurgiões
dc.source.none.fl_str_mv Revista do Colégio Brasileiro de Cirurgiões v.49 2022
reponame:Revista do Colégio Brasileiro de Cirurgiões
instname:Colégio Brasileiro de Cirurgiões (CBC)
instacron:CBC
instname_str Colégio Brasileiro de Cirurgiões (CBC)
instacron_str CBC
institution CBC
reponame_str Revista do Colégio Brasileiro de Cirurgiões
collection Revista do Colégio Brasileiro de Cirurgiões
repository.name.fl_str_mv Revista do Colégio Brasileiro de Cirurgiões - Colégio Brasileiro de Cirurgiões (CBC)
repository.mail.fl_str_mv ||revistacbc@cbc.org.br
_version_ 1754209215409291264