Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia

Detalhes bibliográficos
Autor(a) principal: Borges,Felipe Placeres
Data de Publicação: 2010
Outros Autores: Garcia,Denny Marcos, Cruz,Antonio Augusto Velasco e
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000400005
Resumo: PURPOSE: To determine if the distribution of inter-blink time intervals is constant with repeated measurements with and without topical ocular anesthesia. METHODS: Inter-blink time was measured in 15 normal subjects ranging from 19 to 32 years (mean ± SD= 23.9 ± 3.20) with the magnetic search coil technique on 3 different occasions, the last one with topical ocular anesthesia. RESULTS: One-way analysis of variance for repeated measurements showed that topical anesthesia significantly reduced the blink rate (blinks per minute), which was constant in the first two measurements (F=8.27, p=0.0015. First measurement: mean ± SD= 13.7 ± 7.8; second measurement: 13.1 ± 8.5 SD; with topical anesthesia: = 7.2 ± 4.6). However, distributions shape was not affected when the blink rate was reduced. The three distributions followed a Log Normal pattern, which means that the time interval between blinks was symmetrical when the time logarithm was considered. CONCLUSIONS: Topical ocular anesthesia reduces the rate of spontaneous blinking, but does not change the distribution of inter-blink time interval.
id CBO-2_be10482e70c308cbbe5404975046b8cc
oai_identifier_str oai:scielo:S0004-27492010000400005
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesiaBlinkingBlinking/physiologyAdministration, topicalAnesthesiaOphthalmic solutions/pharmacologyEyelidsPURPOSE: To determine if the distribution of inter-blink time intervals is constant with repeated measurements with and without topical ocular anesthesia. METHODS: Inter-blink time was measured in 15 normal subjects ranging from 19 to 32 years (mean ± SD= 23.9 ± 3.20) with the magnetic search coil technique on 3 different occasions, the last one with topical ocular anesthesia. RESULTS: One-way analysis of variance for repeated measurements showed that topical anesthesia significantly reduced the blink rate (blinks per minute), which was constant in the first two measurements (F=8.27, p=0.0015. First measurement: mean ± SD= 13.7 ± 7.8; second measurement: 13.1 ± 8.5 SD; with topical anesthesia: = 7.2 ± 4.6). However, distributions shape was not affected when the blink rate was reduced. The three distributions followed a Log Normal pattern, which means that the time interval between blinks was symmetrical when the time logarithm was considered. CONCLUSIONS: Topical ocular anesthesia reduces the rate of spontaneous blinking, but does not change the distribution of inter-blink time interval.Conselho Brasileiro de Oftalmologia2010-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000400005Arquivos Brasileiros de Oftalmologia v.73 n.4 2010reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492010000400005info:eu-repo/semantics/openAccessBorges,Felipe PlaceresGarcia,Denny MarcosCruz,Antonio Augusto Velasco eeng2010-10-04T00:00:00Zoai:scielo:S0004-27492010000400005Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2010-10-04T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
title Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
spellingShingle Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
Borges,Felipe Placeres
Blinking
Blinking/physiology
Administration, topical
Anesthesia
Ophthalmic solutions/pharmacology
Eyelids
title_short Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
title_full Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
title_fullStr Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
title_full_unstemmed Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
title_sort Distribution of spontaneous inter-blink interval in repeated measurements with and without topical ocular anesthesia
author Borges,Felipe Placeres
author_facet Borges,Felipe Placeres
Garcia,Denny Marcos
Cruz,Antonio Augusto Velasco e
author_role author
author2 Garcia,Denny Marcos
Cruz,Antonio Augusto Velasco e
author2_role author
author
dc.contributor.author.fl_str_mv Borges,Felipe Placeres
Garcia,Denny Marcos
Cruz,Antonio Augusto Velasco e
dc.subject.por.fl_str_mv Blinking
Blinking/physiology
Administration, topical
Anesthesia
Ophthalmic solutions/pharmacology
Eyelids
topic Blinking
Blinking/physiology
Administration, topical
Anesthesia
Ophthalmic solutions/pharmacology
Eyelids
description PURPOSE: To determine if the distribution of inter-blink time intervals is constant with repeated measurements with and without topical ocular anesthesia. METHODS: Inter-blink time was measured in 15 normal subjects ranging from 19 to 32 years (mean ± SD= 23.9 ± 3.20) with the magnetic search coil technique on 3 different occasions, the last one with topical ocular anesthesia. RESULTS: One-way analysis of variance for repeated measurements showed that topical anesthesia significantly reduced the blink rate (blinks per minute), which was constant in the first two measurements (F=8.27, p=0.0015. First measurement: mean ± SD= 13.7 ± 7.8; second measurement: 13.1 ± 8.5 SD; with topical anesthesia: = 7.2 ± 4.6). However, distributions shape was not affected when the blink rate was reduced. The three distributions followed a Log Normal pattern, which means that the time interval between blinks was symmetrical when the time logarithm was considered. CONCLUSIONS: Topical ocular anesthesia reduces the rate of spontaneous blinking, but does not change the distribution of inter-blink time interval.
publishDate 2010
dc.date.none.fl_str_mv 2010-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000400005
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000400005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27492010000400005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.73 n.4 2010
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209026427584512