High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review

Detalhes bibliográficos
Autor(a) principal: Antonioli,Cleonice Aparecida Silva
Data de Publicação: 2016
Outros Autores: Momensohn-Santos,Teresa Maria, Benaglia,Tatiana Aparecida Silva
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Archives of Otorhinolaryngology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642016000300281
Resumo: Abstract Introduction The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́ s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. Objective This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. Data Synthesis This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. Conclusion The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.
id FORL-1_c52d373c2e39a9a25072f25524bdb4dc
oai_identifier_str oai:scielo:S1809-48642016000300281
network_acronym_str FORL-1
network_name_str International Archives of Otorhinolaryngology
repository_id_str
spelling High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Reviewhigh-frequencyhearing loss caused by noisehearing losshearing testshearingmonitoringAbstract Introduction The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́ s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. Objective This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. Data Synthesis This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. Conclusion The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.Fundação Otorrinolaringologia2016-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642016000300281International Archives of Otorhinolaryngology v.20 n.3 2016reponame:International Archives of Otorhinolaryngologyinstname:Fundação Otorrinolaringologia (FORL)instacron:FORL10.1055/s-0035-1570072info:eu-repo/semantics/openAccessAntonioli,Cleonice Aparecida SilvaMomensohn-Santos,Teresa MariaBenaglia,Tatiana Aparecida Silvaeng2016-09-02T00:00:00Zoai:scielo:S1809-48642016000300281Revistahttps://www.scielo.br/j/iao/https://old.scielo.br/oai/scielo-oai.php||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br1809-48641809-4864opendoar:2016-09-02T00:00International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL)false
dc.title.none.fl_str_mv High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
title High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
spellingShingle High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
Antonioli,Cleonice Aparecida Silva
high-frequency
hearing loss caused by noise
hearing loss
hearing tests
hearing
monitoring
title_short High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
title_full High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
title_fullStr High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
title_full_unstemmed High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
title_sort High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review
author Antonioli,Cleonice Aparecida Silva
author_facet Antonioli,Cleonice Aparecida Silva
Momensohn-Santos,Teresa Maria
Benaglia,Tatiana Aparecida Silva
author_role author
author2 Momensohn-Santos,Teresa Maria
Benaglia,Tatiana Aparecida Silva
author2_role author
author
dc.contributor.author.fl_str_mv Antonioli,Cleonice Aparecida Silva
Momensohn-Santos,Teresa Maria
Benaglia,Tatiana Aparecida Silva
dc.subject.por.fl_str_mv high-frequency
hearing loss caused by noise
hearing loss
hearing tests
hearing
monitoring
topic high-frequency
hearing loss caused by noise
hearing loss
hearing tests
hearing
monitoring
description Abstract Introduction The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́ s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. Objective This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. Data Synthesis This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. Conclusion The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.
publishDate 2016
dc.date.none.fl_str_mv 2016-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642016000300281
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642016000300281
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1055/s-0035-1570072
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Otorrinolaringologia
publisher.none.fl_str_mv Fundação Otorrinolaringologia
dc.source.none.fl_str_mv International Archives of Otorhinolaryngology v.20 n.3 2016
reponame:International Archives of Otorhinolaryngology
instname:Fundação Otorrinolaringologia (FORL)
instacron:FORL
instname_str Fundação Otorrinolaringologia (FORL)
instacron_str FORL
institution FORL
reponame_str International Archives of Otorhinolaryngology
collection International Archives of Otorhinolaryngology
repository.name.fl_str_mv International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL)
repository.mail.fl_str_mv ||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br
_version_ 1754203975616299008