The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat

Detalhes bibliográficos
Autor(a) principal: Kasemsiri,Pornthep
Data de Publicação: 2017
Outros Autores: Mahawerawat,Kanokkan, Ratanaanekchai,Teeraporn, Puttarak,Warinthorn, Munkong,Waranon
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Archives of Otorhinolaryngology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642017000300255
Resumo: Abstract Introduction Some patients with a fishbone as a foreign body of difficult diagnosis may require further investigations. Generally, radiography is used as the first choice for finding the fishbone. Objective The objective of this study is to determine the accuracy of digital radiography for diagnosis of fishbone foreign body in the throat Methods This descriptive experimental study design has three phases. In the first phase, we assessed subject contrast and visibility of fishbone on a homogeneous background; as for the second phase, we evaluated the embedded fishbone in the fresh cadaver’s throat. In the last phase, we studied the accuracy of radiography in diagnosing the fishbone foreign body at any site of the cadaver’s throat. Results The subject contrast of 15 fishbones ranged from 0.94 to 0.99. All types of fishbone were obvious in the first phase, whereas, in the second phase, visibility of fishbone was varied. The subject contrast and diameter of fishbone did not show statistically significant correlation with visibility (p = 0.09 and p = 0.24, respectively). In the third phase, embedded fishbone in the base of tongue was detected with the highest accuracy (sensitivity of 1.00 (95%CI: 0.44-1.00) and specificity of 0.92 (95%CI: 0.65-0.99)); whereas, the tonsil was of difficult interpretation with poorest diagnostic value (sensitivity of 0.00 (95%CI: 0.00-0.56) and specificity of 1.00 (95%CI: 0.76-1.00)). Conclusion The digital radiography provides the highest accuracy and benefit to the diagnosis of a fishbone foreign body at the base of the tongue; whereas, the tonsil was of difficult interpretation.
id FORL-1_c5610eb84fbee246ef51d89a2d589835
oai_identifier_str oai:scielo:S1809-48642017000300255
network_acronym_str FORL-1
network_name_str International Archives of Otorhinolaryngology
repository_id_str
spelling The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throatfishboneforeign bodyradiographysensitivityspecificityAbstract Introduction Some patients with a fishbone as a foreign body of difficult diagnosis may require further investigations. Generally, radiography is used as the first choice for finding the fishbone. Objective The objective of this study is to determine the accuracy of digital radiography for diagnosis of fishbone foreign body in the throat Methods This descriptive experimental study design has three phases. In the first phase, we assessed subject contrast and visibility of fishbone on a homogeneous background; as for the second phase, we evaluated the embedded fishbone in the fresh cadaver’s throat. In the last phase, we studied the accuracy of radiography in diagnosing the fishbone foreign body at any site of the cadaver’s throat. Results The subject contrast of 15 fishbones ranged from 0.94 to 0.99. All types of fishbone were obvious in the first phase, whereas, in the second phase, visibility of fishbone was varied. The subject contrast and diameter of fishbone did not show statistically significant correlation with visibility (p = 0.09 and p = 0.24, respectively). In the third phase, embedded fishbone in the base of tongue was detected with the highest accuracy (sensitivity of 1.00 (95%CI: 0.44-1.00) and specificity of 0.92 (95%CI: 0.65-0.99)); whereas, the tonsil was of difficult interpretation with poorest diagnostic value (sensitivity of 0.00 (95%CI: 0.00-0.56) and specificity of 1.00 (95%CI: 0.76-1.00)). Conclusion The digital radiography provides the highest accuracy and benefit to the diagnosis of a fishbone foreign body at the base of the tongue; whereas, the tonsil was of difficult interpretation.Fundação Otorrinolaringologia2017-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642017000300255International Archives of Otorhinolaryngology v.21 n.3 2017reponame:International Archives of Otorhinolaryngologyinstname:Fundação Otorrinolaringologia (FORL)instacron:FORL10.1055/s-0036-1597811info:eu-repo/semantics/openAccessKasemsiri,PornthepMahawerawat,KanokkanRatanaanekchai,TeerapornPuttarak,WarinthornMunkong,Waranoneng2017-09-19T00:00:00Zoai:scielo:S1809-48642017000300255Revistahttps://www.scielo.br/j/iao/https://old.scielo.br/oai/scielo-oai.php||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br1809-48641809-4864opendoar:2017-09-19T00:00International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL)false
dc.title.none.fl_str_mv The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
title The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
spellingShingle The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
Kasemsiri,Pornthep
fishbone
foreign body
radiography
sensitivity
specificity
title_short The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
title_full The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
title_fullStr The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
title_full_unstemmed The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
title_sort The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
author Kasemsiri,Pornthep
author_facet Kasemsiri,Pornthep
Mahawerawat,Kanokkan
Ratanaanekchai,Teeraporn
Puttarak,Warinthorn
Munkong,Waranon
author_role author
author2 Mahawerawat,Kanokkan
Ratanaanekchai,Teeraporn
Puttarak,Warinthorn
Munkong,Waranon
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Kasemsiri,Pornthep
Mahawerawat,Kanokkan
Ratanaanekchai,Teeraporn
Puttarak,Warinthorn
Munkong,Waranon
dc.subject.por.fl_str_mv fishbone
foreign body
radiography
sensitivity
specificity
topic fishbone
foreign body
radiography
sensitivity
specificity
description Abstract Introduction Some patients with a fishbone as a foreign body of difficult diagnosis may require further investigations. Generally, radiography is used as the first choice for finding the fishbone. Objective The objective of this study is to determine the accuracy of digital radiography for diagnosis of fishbone foreign body in the throat Methods This descriptive experimental study design has three phases. In the first phase, we assessed subject contrast and visibility of fishbone on a homogeneous background; as for the second phase, we evaluated the embedded fishbone in the fresh cadaver’s throat. In the last phase, we studied the accuracy of radiography in diagnosing the fishbone foreign body at any site of the cadaver’s throat. Results The subject contrast of 15 fishbones ranged from 0.94 to 0.99. All types of fishbone were obvious in the first phase, whereas, in the second phase, visibility of fishbone was varied. The subject contrast and diameter of fishbone did not show statistically significant correlation with visibility (p = 0.09 and p = 0.24, respectively). In the third phase, embedded fishbone in the base of tongue was detected with the highest accuracy (sensitivity of 1.00 (95%CI: 0.44-1.00) and specificity of 0.92 (95%CI: 0.65-0.99)); whereas, the tonsil was of difficult interpretation with poorest diagnostic value (sensitivity of 0.00 (95%CI: 0.00-0.56) and specificity of 1.00 (95%CI: 0.76-1.00)). Conclusion The digital radiography provides the highest accuracy and benefit to the diagnosis of a fishbone foreign body at the base of the tongue; whereas, the tonsil was of difficult interpretation.
publishDate 2017
dc.date.none.fl_str_mv 2017-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642017000300255
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642017000300255
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1055/s-0036-1597811
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Otorrinolaringologia
publisher.none.fl_str_mv Fundação Otorrinolaringologia
dc.source.none.fl_str_mv International Archives of Otorhinolaryngology v.21 n.3 2017
reponame:International Archives of Otorhinolaryngology
instname:Fundação Otorrinolaringologia (FORL)
instacron:FORL
instname_str Fundação Otorrinolaringologia (FORL)
instacron_str FORL
institution FORL
reponame_str International Archives of Otorhinolaryngology
collection International Archives of Otorhinolaryngology
repository.name.fl_str_mv International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL)
repository.mail.fl_str_mv ||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br
_version_ 1754203975722205184