Molar intrusion with orthodontic mini-implants: case reports

Detalhes bibliográficos
Autor(a) principal: TIAGO,Carollyne Mota
Data de Publicação: 2016
Outros Autores: PREVIDENTE,Luis, NOUER,Paulo Roberto Aranha
Tipo de documento: Artigo
Idioma: eng
Título da fonte: RGO - Revista Gaúcha de Odontologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372016000300327
Resumo: ABSTRACT Intraoral skeletal anchorage may be obtained by means of mini-implants that allow simpler and more effective orthodontic biomechanics. These devices have become increasingly popular, particularly because their use requires little cooperation from the patient. Three clinical cases were presented, in which the efficiency of mini-implants for maxillary and mandibular molar intrusion was demonstrated. In all treatments, the authors sought to insert the mini-implants in the vestibular and lingual regions to obtain better torque control of the tooth, thereby avoiding undesirable momentum, rotation and tipping. Therefore, the intrusive forces with a force intensity ranging between 150g and 200g, were obtained by means of chain elastics, always passing through the center of resistance of the molars to be moved. In the cases treated, there was intrusion with over-correction in a mean period of six, and maximum of seven months, thus allowing better rehabilitation of the patient submitted to previous orthodontic treatment, and after conclusion of this phase, good stability of the mechanics used.
id FSLM-1_c651d07c6ad0c16f14ee126e5b3a3c54
oai_identifier_str oai:scielo:S1981-86372016000300327
network_acronym_str FSLM-1
network_name_str RGO - Revista Gaúcha de Odontologia (Online)
repository_id_str
spelling Molar intrusion with orthodontic mini-implants: case reportsDental implantationOrthodonticsTooth movementABSTRACT Intraoral skeletal anchorage may be obtained by means of mini-implants that allow simpler and more effective orthodontic biomechanics. These devices have become increasingly popular, particularly because their use requires little cooperation from the patient. Three clinical cases were presented, in which the efficiency of mini-implants for maxillary and mandibular molar intrusion was demonstrated. In all treatments, the authors sought to insert the mini-implants in the vestibular and lingual regions to obtain better torque control of the tooth, thereby avoiding undesirable momentum, rotation and tipping. Therefore, the intrusive forces with a force intensity ranging between 150g and 200g, were obtained by means of chain elastics, always passing through the center of resistance of the molars to be moved. In the cases treated, there was intrusion with over-correction in a mean period of six, and maximum of seven months, thus allowing better rehabilitation of the patient submitted to previous orthodontic treatment, and after conclusion of this phase, good stability of the mechanics used.Faculdade São Leopoldo Mandic2016-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372016000300327RGO - Revista Gaúcha de Odontologia v.64 n.3 2016reponame:RGO - Revista Gaúcha de Odontologia (Online)instname:Faculdade São Leopoldo Mandic (FSLM)instacron:FSLM10.1590/1981-8637201600030000133274info:eu-repo/semantics/openAccessTIAGO,Carollyne MotaPREVIDENTE,LuisNOUER,Paulo Roberto Aranhaeng2019-08-06T00:00:00Zoai:scielo:S1981-86372016000300327Revistahttp://revodonto.bvsalud.org/scielo.php?script=sci_serial&pid=1981-8637&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.php||contato@revistargo.com.br1981-86370103-6971opendoar:2019-08-06T00:00RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM)false
dc.title.none.fl_str_mv Molar intrusion with orthodontic mini-implants: case reports
title Molar intrusion with orthodontic mini-implants: case reports
spellingShingle Molar intrusion with orthodontic mini-implants: case reports
TIAGO,Carollyne Mota
Dental implantation
Orthodontics
Tooth movement
title_short Molar intrusion with orthodontic mini-implants: case reports
title_full Molar intrusion with orthodontic mini-implants: case reports
title_fullStr Molar intrusion with orthodontic mini-implants: case reports
title_full_unstemmed Molar intrusion with orthodontic mini-implants: case reports
title_sort Molar intrusion with orthodontic mini-implants: case reports
author TIAGO,Carollyne Mota
author_facet TIAGO,Carollyne Mota
PREVIDENTE,Luis
NOUER,Paulo Roberto Aranha
author_role author
author2 PREVIDENTE,Luis
NOUER,Paulo Roberto Aranha
author2_role author
author
dc.contributor.author.fl_str_mv TIAGO,Carollyne Mota
PREVIDENTE,Luis
NOUER,Paulo Roberto Aranha
dc.subject.por.fl_str_mv Dental implantation
Orthodontics
Tooth movement
topic Dental implantation
Orthodontics
Tooth movement
description ABSTRACT Intraoral skeletal anchorage may be obtained by means of mini-implants that allow simpler and more effective orthodontic biomechanics. These devices have become increasingly popular, particularly because their use requires little cooperation from the patient. Three clinical cases were presented, in which the efficiency of mini-implants for maxillary and mandibular molar intrusion was demonstrated. In all treatments, the authors sought to insert the mini-implants in the vestibular and lingual regions to obtain better torque control of the tooth, thereby avoiding undesirable momentum, rotation and tipping. Therefore, the intrusive forces with a force intensity ranging between 150g and 200g, were obtained by means of chain elastics, always passing through the center of resistance of the molars to be moved. In the cases treated, there was intrusion with over-correction in a mean period of six, and maximum of seven months, thus allowing better rehabilitation of the patient submitted to previous orthodontic treatment, and after conclusion of this phase, good stability of the mechanics used.
publishDate 2016
dc.date.none.fl_str_mv 2016-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372016000300327
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372016000300327
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1981-8637201600030000133274
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade São Leopoldo Mandic
publisher.none.fl_str_mv Faculdade São Leopoldo Mandic
dc.source.none.fl_str_mv RGO - Revista Gaúcha de Odontologia v.64 n.3 2016
reponame:RGO - Revista Gaúcha de Odontologia (Online)
instname:Faculdade São Leopoldo Mandic (FSLM)
instacron:FSLM
instname_str Faculdade São Leopoldo Mandic (FSLM)
instacron_str FSLM
institution FSLM
reponame_str RGO - Revista Gaúcha de Odontologia (Online)
collection RGO - Revista Gaúcha de Odontologia (Online)
repository.name.fl_str_mv RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM)
repository.mail.fl_str_mv ||contato@revistargo.com.br
_version_ 1754204121595904000