Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact

Detalhes bibliográficos
Autor(a) principal: Alves,Júlio César de Carvalho
Data de Publicação: 2020
Outros Autores: Borges,Gilberto Antônio, Versluis,Antheunis, Soares,Carlos José, Veríssimo,Crisnicaw
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402020000500540
Resumo: Abstract The aim of this study was to analyze the influence of orthodontic bracket type (metallic or ceramic) and mouthguard on biomechanical response during impact. Two-dimensional plane-strain models of a patient with increased positive overjet of the maxillary central incisor was created based on a CT scan, simulating the periodontal ligament, bone support, gingival tissue, orthodontic brackets (metallic or ceramic) and mouthguard. A nonlinear dynamic impact finite element analysis was performed in which a steel object hit the model at 1 m/s. Stress distributions (Von Mises and Modified Von Mises) and strain were evaluated. Stress distributions were affected by the bracket presence and type. Models with metallic and ceramic bracket had higher stresses over a larger buccal enamel impact area. Models with ceramic brackets generated higher stresses than the metallic brackets. Mouthguards reduced the stress and strain values regardless of bracket type. Mouthguard shock absorption were 88.37% and 89.27% for the metallic and ceramic bracket, respectively. Orthodontic bracket presence and type influenced the stress and strain generated during an impact. Ceramic brackets generated higher stresses than metallic brackets. Mouthguards substantially reduced impact stress and strain peaks, regardless of bracket type.
id FUNORP-1_22b93865a0c18d5a58d7ed81e1d04dda
oai_identifier_str oai:scielo:S0103-64402020000500540
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impactmouth guardbiomechanical phenomenafinite element analysisorthodontics bracketsAbstract The aim of this study was to analyze the influence of orthodontic bracket type (metallic or ceramic) and mouthguard on biomechanical response during impact. Two-dimensional plane-strain models of a patient with increased positive overjet of the maxillary central incisor was created based on a CT scan, simulating the periodontal ligament, bone support, gingival tissue, orthodontic brackets (metallic or ceramic) and mouthguard. A nonlinear dynamic impact finite element analysis was performed in which a steel object hit the model at 1 m/s. Stress distributions (Von Mises and Modified Von Mises) and strain were evaluated. Stress distributions were affected by the bracket presence and type. Models with metallic and ceramic bracket had higher stresses over a larger buccal enamel impact area. Models with ceramic brackets generated higher stresses than the metallic brackets. Mouthguards reduced the stress and strain values regardless of bracket type. Mouthguard shock absorption were 88.37% and 89.27% for the metallic and ceramic bracket, respectively. Orthodontic bracket presence and type influenced the stress and strain generated during an impact. Ceramic brackets generated higher stresses than metallic brackets. Mouthguards substantially reduced impact stress and strain peaks, regardless of bracket type.Fundação Odontológica de Ribeirão Preto2020-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402020000500540Brazilian Dental Journal v.31 n.5 2020reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440202002818info:eu-repo/semantics/openAccessAlves,Júlio César de CarvalhoBorges,Gilberto AntônioVersluis,AntheunisSoares,Carlos JoséVeríssimo,Crisnicaweng2020-10-29T00:00:00Zoai:scielo:S0103-64402020000500540Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2020-10-29T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
title Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
spellingShingle Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
Alves,Júlio César de Carvalho
mouth guard
biomechanical phenomena
finite element analysis
orthodontics brackets
title_short Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
title_full Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
title_fullStr Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
title_full_unstemmed Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
title_sort Effect of Orthodontic Bracket Type and Mouthguard Presence on the Stress and Strain during a Frontal Impact
author Alves,Júlio César de Carvalho
author_facet Alves,Júlio César de Carvalho
Borges,Gilberto Antônio
Versluis,Antheunis
Soares,Carlos José
Veríssimo,Crisnicaw
author_role author
author2 Borges,Gilberto Antônio
Versluis,Antheunis
Soares,Carlos José
Veríssimo,Crisnicaw
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Alves,Júlio César de Carvalho
Borges,Gilberto Antônio
Versluis,Antheunis
Soares,Carlos José
Veríssimo,Crisnicaw
dc.subject.por.fl_str_mv mouth guard
biomechanical phenomena
finite element analysis
orthodontics brackets
topic mouth guard
biomechanical phenomena
finite element analysis
orthodontics brackets
description Abstract The aim of this study was to analyze the influence of orthodontic bracket type (metallic or ceramic) and mouthguard on biomechanical response during impact. Two-dimensional plane-strain models of a patient with increased positive overjet of the maxillary central incisor was created based on a CT scan, simulating the periodontal ligament, bone support, gingival tissue, orthodontic brackets (metallic or ceramic) and mouthguard. A nonlinear dynamic impact finite element analysis was performed in which a steel object hit the model at 1 m/s. Stress distributions (Von Mises and Modified Von Mises) and strain were evaluated. Stress distributions were affected by the bracket presence and type. Models with metallic and ceramic bracket had higher stresses over a larger buccal enamel impact area. Models with ceramic brackets generated higher stresses than the metallic brackets. Mouthguards reduced the stress and strain values regardless of bracket type. Mouthguard shock absorption were 88.37% and 89.27% for the metallic and ceramic bracket, respectively. Orthodontic bracket presence and type influenced the stress and strain generated during an impact. Ceramic brackets generated higher stresses than metallic brackets. Mouthguards substantially reduced impact stress and strain peaks, regardless of bracket type.
publishDate 2020
dc.date.none.fl_str_mv 2020-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402020000500540
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402020000500540
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440202002818
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.31 n.5 2020
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204096152207360