Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402014000400357 |
Resumo: | Excessive occlusal surface wear can result in occlusal disharmony, functional and esthetic impairment. As a therapeutic approach, conventional single crowns have been proposed, but this kind of treatment is complex, highly invasive and expensive. This case report describes the clinical outcomes of an alternative minimally invasive treatment based on direct adhesive-pin retained restorations. A 64-year-old woman with severely worn dentition, eating problems related to missing teeth and generalized tooth hypersensitivity was referred for treatment. Proper treatment planning based on the diagnostic wax-up simulation was used to guide the reconstruction of maxillary anterior teeth with direct composite resin over self-threading dentin pins. As the mandibular remaining teeth were extremely worn, a tooth-supported overdenture was installed. A stabilization splint was also used to protect the restorations. This treatment was a less expensive alternative to full-mouth rehabilitation with positive esthetic and functional outcomes after 1.5 years of follow-up. |
id |
FUNORP-1_acab463379169067e6cd962cf5c08708 |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402014000400357 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Reporttooth weardentinal pinsocclusal vertical dimensionfull-mouth rehabilitationcase reportExcessive occlusal surface wear can result in occlusal disharmony, functional and esthetic impairment. As a therapeutic approach, conventional single crowns have been proposed, but this kind of treatment is complex, highly invasive and expensive. This case report describes the clinical outcomes of an alternative minimally invasive treatment based on direct adhesive-pin retained restorations. A 64-year-old woman with severely worn dentition, eating problems related to missing teeth and generalized tooth hypersensitivity was referred for treatment. Proper treatment planning based on the diagnostic wax-up simulation was used to guide the reconstruction of maxillary anterior teeth with direct composite resin over self-threading dentin pins. As the mandibular remaining teeth were extremely worn, a tooth-supported overdenture was installed. A stabilization splint was also used to protect the restorations. This treatment was a less expensive alternative to full-mouth rehabilitation with positive esthetic and functional outcomes after 1.5 years of follow-up.Fundação Odontológica de Ribeirão Preto2014-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402014000400357Brazilian Dental Journal v.25 n.4 2014reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201300020info:eu-repo/semantics/openAccessAndrade,Camila Lima deGonçalves,Thais Marques Simek VegaSantos,Ícaro Leite dosBarros,Michel SilvaAraújo,Nubia Rafaela RibeiroCury,Altair Antoninha Del Beleng2014-09-18T00:00:00Zoai:scielo:S0103-64402014000400357Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2014-09-18T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report |
title |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report |
spellingShingle |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report Andrade,Camila Lima de tooth wear dentinal pins occlusal vertical dimension full-mouth rehabilitation case report |
title_short |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report |
title_full |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report |
title_fullStr |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report |
title_full_unstemmed |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report |
title_sort |
Direct Adhesive Pin-Retained Restorations for Severely Worn Dentition Treatment: A 1.5-Year Follow-Up Report |
author |
Andrade,Camila Lima de |
author_facet |
Andrade,Camila Lima de Gonçalves,Thais Marques Simek Vega Santos,Ícaro Leite dos Barros,Michel Silva Araújo,Nubia Rafaela Ribeiro Cury,Altair Antoninha Del Bel |
author_role |
author |
author2 |
Gonçalves,Thais Marques Simek Vega Santos,Ícaro Leite dos Barros,Michel Silva Araújo,Nubia Rafaela Ribeiro Cury,Altair Antoninha Del Bel |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Andrade,Camila Lima de Gonçalves,Thais Marques Simek Vega Santos,Ícaro Leite dos Barros,Michel Silva Araújo,Nubia Rafaela Ribeiro Cury,Altair Antoninha Del Bel |
dc.subject.por.fl_str_mv |
tooth wear dentinal pins occlusal vertical dimension full-mouth rehabilitation case report |
topic |
tooth wear dentinal pins occlusal vertical dimension full-mouth rehabilitation case report |
description |
Excessive occlusal surface wear can result in occlusal disharmony, functional and esthetic impairment. As a therapeutic approach, conventional single crowns have been proposed, but this kind of treatment is complex, highly invasive and expensive. This case report describes the clinical outcomes of an alternative minimally invasive treatment based on direct adhesive-pin retained restorations. A 64-year-old woman with severely worn dentition, eating problems related to missing teeth and generalized tooth hypersensitivity was referred for treatment. Proper treatment planning based on the diagnostic wax-up simulation was used to guide the reconstruction of maxillary anterior teeth with direct composite resin over self-threading dentin pins. As the mandibular remaining teeth were extremely worn, a tooth-supported overdenture was installed. A stabilization splint was also used to protect the restorations. This treatment was a less expensive alternative to full-mouth rehabilitation with positive esthetic and functional outcomes after 1.5 years of follow-up. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402014000400357 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402014000400357 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0103-6440201300020 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.25 n.4 2014 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204093133357056 |