Surface finishing of unused rotary endodontic instruments: a SEM study

Detalhes bibliográficos
Autor(a) principal: Chianello,Giovani
Data de Publicação: 2008
Outros Autores: Specian,Vivyane Leal, Hardt,Lilian Cristina Fucuda, Raldi,Denise Pontes, Lage-Marques,José Luiz, Habitante,Sandra Márcia
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000200004
Resumo: During endodontic therapy, cleaning of root canals is performed using endodontic files and auxiliary chemical substances, and it is important that the endodontist be familiar with the instruments used in daily practice. This study evaluated, under scanning electron microscopy (SEM), the quality of the surface finishing of unused rotary endodontic instruments. Fifty sizes 20, 25 and 30 rotary files from different commercial brands (ProFile, Protaper, Race, Hero and K3 Endo) were removed directly from their packages and had their final 3 mm examined with a scanning electron microscope at x190 magnification with no previous preparation. The images were evaluated by 3 skillful, calibrated, blinded observers according to the following criteria: cutting edge, debris, grooves, microcavities, tip shape, tip position, scraping and transition angle. Data were recorded in worksheets designed for the study. Irregular edges were observed in 50-100% of the files. Except for ProFile, all commercial brands presented surface debris in 100% of samples. Only Race files showed no grooves or microcavities. K3 Endo files presented the best tip centralization. Excetp for ProTaper files, all commercial brands presented blunt-cutting edges in 100% of samples. All types of files presented surface scraping. K3 Endo files and Protaper had a high percentage of transition angle. Based on the evaluation criteria used in the present study, most samples presented a minimum of 2 alterations and a maximum of 7 alterations per instrument. Under the tested conditions, the quality of the surface finishing of the examined instruments was not as expected, given that no instrument was free of imperfections and most of them presented at least 2 and up to 7 types of surface defects. These results suggest that the manufacturing process and the packaging conditions of rotary endodontic instruments are far from ideal.
id FUNORP-1_fbf2bb41584ca43b145529e316226f0d
oai_identifier_str oai:scielo:S0103-64402008000200004
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Surface finishing of unused rotary endodontic instruments: a SEM studyendodontic instrumentssurface finishingscanning electron microscopymanufacturing defectsDuring endodontic therapy, cleaning of root canals is performed using endodontic files and auxiliary chemical substances, and it is important that the endodontist be familiar with the instruments used in daily practice. This study evaluated, under scanning electron microscopy (SEM), the quality of the surface finishing of unused rotary endodontic instruments. Fifty sizes 20, 25 and 30 rotary files from different commercial brands (ProFile, Protaper, Race, Hero and K3 Endo) were removed directly from their packages and had their final 3 mm examined with a scanning electron microscope at x190 magnification with no previous preparation. The images were evaluated by 3 skillful, calibrated, blinded observers according to the following criteria: cutting edge, debris, grooves, microcavities, tip shape, tip position, scraping and transition angle. Data were recorded in worksheets designed for the study. Irregular edges were observed in 50-100% of the files. Except for ProFile, all commercial brands presented surface debris in 100% of samples. Only Race files showed no grooves or microcavities. K3 Endo files presented the best tip centralization. Excetp for ProTaper files, all commercial brands presented blunt-cutting edges in 100% of samples. All types of files presented surface scraping. K3 Endo files and Protaper had a high percentage of transition angle. Based on the evaluation criteria used in the present study, most samples presented a minimum of 2 alterations and a maximum of 7 alterations per instrument. Under the tested conditions, the quality of the surface finishing of the examined instruments was not as expected, given that no instrument was free of imperfections and most of them presented at least 2 and up to 7 types of surface defects. These results suggest that the manufacturing process and the packaging conditions of rotary endodontic instruments are far from ideal.Fundação Odontológica de Ribeirão Preto2008-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000200004Brazilian Dental Journal v.19 n.2 2008reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402008000200004info:eu-repo/semantics/openAccessChianello,GiovaniSpecian,Vivyane LealHardt,Lilian Cristina FucudaRaldi,Denise PontesLage-Marques,José LuizHabitante,Sandra Márciaeng2008-06-12T00:00:00Zoai:scielo:S0103-64402008000200004Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2008-06-12T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Surface finishing of unused rotary endodontic instruments: a SEM study
title Surface finishing of unused rotary endodontic instruments: a SEM study
spellingShingle Surface finishing of unused rotary endodontic instruments: a SEM study
Chianello,Giovani
endodontic instruments
surface finishing
scanning electron microscopy
manufacturing defects
title_short Surface finishing of unused rotary endodontic instruments: a SEM study
title_full Surface finishing of unused rotary endodontic instruments: a SEM study
title_fullStr Surface finishing of unused rotary endodontic instruments: a SEM study
title_full_unstemmed Surface finishing of unused rotary endodontic instruments: a SEM study
title_sort Surface finishing of unused rotary endodontic instruments: a SEM study
author Chianello,Giovani
author_facet Chianello,Giovani
Specian,Vivyane Leal
Hardt,Lilian Cristina Fucuda
Raldi,Denise Pontes
Lage-Marques,José Luiz
Habitante,Sandra Márcia
author_role author
author2 Specian,Vivyane Leal
Hardt,Lilian Cristina Fucuda
Raldi,Denise Pontes
Lage-Marques,José Luiz
Habitante,Sandra Márcia
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Chianello,Giovani
Specian,Vivyane Leal
Hardt,Lilian Cristina Fucuda
Raldi,Denise Pontes
Lage-Marques,José Luiz
Habitante,Sandra Márcia
dc.subject.por.fl_str_mv endodontic instruments
surface finishing
scanning electron microscopy
manufacturing defects
topic endodontic instruments
surface finishing
scanning electron microscopy
manufacturing defects
description During endodontic therapy, cleaning of root canals is performed using endodontic files and auxiliary chemical substances, and it is important that the endodontist be familiar with the instruments used in daily practice. This study evaluated, under scanning electron microscopy (SEM), the quality of the surface finishing of unused rotary endodontic instruments. Fifty sizes 20, 25 and 30 rotary files from different commercial brands (ProFile, Protaper, Race, Hero and K3 Endo) were removed directly from their packages and had their final 3 mm examined with a scanning electron microscope at x190 magnification with no previous preparation. The images were evaluated by 3 skillful, calibrated, blinded observers according to the following criteria: cutting edge, debris, grooves, microcavities, tip shape, tip position, scraping and transition angle. Data were recorded in worksheets designed for the study. Irregular edges were observed in 50-100% of the files. Except for ProFile, all commercial brands presented surface debris in 100% of samples. Only Race files showed no grooves or microcavities. K3 Endo files presented the best tip centralization. Excetp for ProTaper files, all commercial brands presented blunt-cutting edges in 100% of samples. All types of files presented surface scraping. K3 Endo files and Protaper had a high percentage of transition angle. Based on the evaluation criteria used in the present study, most samples presented a minimum of 2 alterations and a maximum of 7 alterations per instrument. Under the tested conditions, the quality of the surface finishing of the examined instruments was not as expected, given that no instrument was free of imperfections and most of them presented at least 2 and up to 7 types of surface defects. These results suggest that the manufacturing process and the packaging conditions of rotary endodontic instruments are far from ideal.
publishDate 2008
dc.date.none.fl_str_mv 2008-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000200004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000200004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402008000200004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.19 n.2 2008
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204090853752832